- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT00845624
Time Outside Target Oxygen Saturation Range in Preterm Infants and Long Term Outcomes and Preterm Infants (SAT01ROP)
DURATION OF TIME OUTSIDE, BELOW, AND ABOVE THE TARGETED Oxygen SATURATION RANGE In Preterm Infants
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
All infants who had a birth weight of less than 1500 grams or less than 32 weeks gestation admitted to our neonatal intensive care unit (NICU) were eligible for the study. All infants were placed on Nellcor N600 pulsoximetry. Saturation data in two-second sampling from N600 OXIMAX pulse oximeters (Covidian, CA) was collected using a modified Nellcor® Oxinet® III system (Covidian, CA and Cardiopulmonary, Milford, CT) Alarm limits were set at 83% and 93% while infants required oxygen supplementation and 85% to 100% when neonates were in room air. Desaturation events were defined as number of times the saturation fell below the low saturation limit set on the monitor (83% if oxygen requirement >21%, 85% if patient on room air). High saturation events were defined as the number of times the patient's saturation was above the upper saturation limit (93% if oxygen requirement >21%)
The data collection system summarized each day in tabular form including average SPO2, number of low and high SPO2 events, duration of events in minutes, and the percentage of time infants spent outside of the intended saturation range. Primary outcome was threshold ROP requiring laser ablation. Data on ROP was collected during hospitalization and after discharge until resolution of ROP by pediatric ophthalmologist blinded to the study results. Secondary outcomes included bronchopulmonary dysplasia, length of hospitalization, sepsis, focal bowel perforation, necrotizing enterocolitis (stage 2 or greater), patent ductus ligation, intracranial hemorrhage, and number of red blood cell and platelet transfusions.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Virginia
-
Charlottesville, Virginia, Stati Uniti, 22908
- University of Virginia Neonatal Intensive Care Unit
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Preterm infants <1500 grams or <32 weeks gestation
Exclusion Criteria:
- None
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
|---|
|
1
Preterm infants <1500 grams or 32 weeks gestation.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Retinopathy of prematurity
Lasso di tempo: 4 weeks to 52 weeks of life
|
4 weeks to 52 weeks of life
|
Misure di risultato secondarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Time outside targeted saturation range
Lasso di tempo: entire hospitalization
|
entire hospitalization
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: David Kaufman, MD, University of Virginia
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 12213 (Company Internal)
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .