Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

South American Abdominal Stent Graft Trial

3 giugno 2021 aggiornato da: TriVascular, Inc.

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Modular Abdominal Stent Graft System

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System

Panoramica dello studio

Descrizione dettagliata

This study is a prospective, non-randomized multi-center clinical evaluation of the safety and performance of the TriVascular Modular Abdominal Stent Graft System when used in the treatment of subjects with abdominal aortic aneurysms (AAA).

Tipo di studio

Interventistico

Iscrizione (Effettivo)

20

Fase

  • Fase 1

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Santiago, Chile
        • Pontificia Universidad Catolica de Chile

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  1. Patient is > 18 years of age
  2. Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
  3. Patient has signed an Ethics Committee approved Informed Consent Form
  4. Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
  5. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:

    1. Abdominal aortic aneurysm >5.0 cm in diameter,
    2. Aneurysm that has increased in size by 0.5 cm in last 6 months,
    3. Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment.
  6. Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System.
  7. Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
  8. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
  9. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
  10. Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm.
  11. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
  12. Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm.
  13. Patient must be able and willing to comply with all required follow-up exams.

Exclusion Criteria:

  1. Patient has a dissecting aneurysm.
  2. Patient has an acutely ruptured aneurysm.
  3. Patient has an acute vascular injury.
  4. Patient has need for emergent surgery.
  5. Patient has a known thoracic aortic aneurysm or dissection.
  6. Patient has a mycotic aneurysm or has an active systemic infection..
  7. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
  8. Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
  9. Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair.
  10. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
  11. Patient has history of bleeding disorders or refuses blood transfusions.
  12. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl.
  13. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  14. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol.
  15. Patient has a body habitus that would inhibit X-ray visualization of the aorta
  16. Patient has a limited life expectancy of less than 1 year
  17. Patient is currently participating in an investigational device or drug clinical trial.
  18. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Altro: Ovation Abdominal Stent Graft System
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
Lasso di tempo: 30-Days
30-Days

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Francisco Valdes, MD, Pontificia Universidad Catolica de Chile

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Collegamenti utili

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 novembre 2009

Completamento primario (Effettivo)

3 marzo 2011

Completamento dello studio (Effettivo)

3 febbraio 2016

Date di iscrizione allo studio

Primo inviato

4 marzo 2010

Primo inviato che soddisfa i criteri di controllo qualità

5 marzo 2010

Primo Inserito (Stima)

8 marzo 2010

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

4 giugno 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

3 giugno 2021

Ultimo verificato

1 giugno 2021

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 771-0002

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Ovation Abdominal Stent Graft System

Sottoscrivi