Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

South American Abdominal Stent Graft Trial

3 de junio de 2021 actualizado por: TriVascular, Inc.

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Modular Abdominal Stent Graft System

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System

Descripción general del estudio

Estado

Terminado

Descripción detallada

This study is a prospective, non-randomized multi-center clinical evaluation of the safety and performance of the TriVascular Modular Abdominal Stent Graft System when used in the treatment of subjects with abdominal aortic aneurysms (AAA).

Tipo de estudio

Intervencionista

Inscripción (Actual)

20

Fase

  • Fase 1

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Santiago, Chile
        • Pontificia Universidad Catolica de Chile

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. Patient is > 18 years of age
  2. Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
  3. Patient has signed an Ethics Committee approved Informed Consent Form
  4. Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
  5. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:

    1. Abdominal aortic aneurysm >5.0 cm in diameter,
    2. Aneurysm that has increased in size by 0.5 cm in last 6 months,
    3. Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment.
  6. Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System.
  7. Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
  8. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
  9. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
  10. Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm.
  11. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
  12. Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm.
  13. Patient must be able and willing to comply with all required follow-up exams.

Exclusion Criteria:

  1. Patient has a dissecting aneurysm.
  2. Patient has an acutely ruptured aneurysm.
  3. Patient has an acute vascular injury.
  4. Patient has need for emergent surgery.
  5. Patient has a known thoracic aortic aneurysm or dissection.
  6. Patient has a mycotic aneurysm or has an active systemic infection..
  7. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
  8. Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
  9. Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair.
  10. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
  11. Patient has history of bleeding disorders or refuses blood transfusions.
  12. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl.
  13. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  14. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol.
  15. Patient has a body habitus that would inhibit X-ray visualization of the aorta
  16. Patient has a limited life expectancy of less than 1 year
  17. Patient is currently participating in an investigational device or drug clinical trial.
  18. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Otro: Ovation Abdominal Stent Graft System
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
Periodo de tiempo: 30-Days
30-Days

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Francisco Valdes, MD, Pontificia Universidad Catolica de Chile

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Enlaces Útiles

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de noviembre de 2009

Finalización primaria (Actual)

3 de marzo de 2011

Finalización del estudio (Actual)

3 de febrero de 2016

Fechas de registro del estudio

Enviado por primera vez

4 de marzo de 2010

Primero enviado que cumplió con los criterios de control de calidad

5 de marzo de 2010

Publicado por primera vez (Estimar)

8 de marzo de 2010

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

4 de junio de 2021

Última actualización enviada que cumplió con los criterios de control de calidad

3 de junio de 2021

Última verificación

1 de junio de 2021

Más información

Términos relacionados con este estudio

Palabras clave

Otros números de identificación del estudio

  • 771-0002

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Ensayos clínicos sobre Aneurisma aórtico abdominal

Ensayos clínicos sobre Ovation Abdominal Stent Graft System