South American Abdominal Stent Graft Trial

3. června 2021 aktualizováno: TriVascular, Inc.

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Modular Abdominal Stent Graft System

A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System

Přehled studie

Postavení

Dokončeno

Detailní popis

This study is a prospective, non-randomized multi-center clinical evaluation of the safety and performance of the TriVascular Modular Abdominal Stent Graft System when used in the treatment of subjects with abdominal aortic aneurysms (AAA).

Typ studie

Intervenční

Zápis (Aktuální)

20

Fáze

  • Fáze 1

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Santiago, Chile
        • Pontificia Universidad Catolica de Chile

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  1. Patient is > 18 years of age
  2. Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
  3. Patient has signed an Ethics Committee approved Informed Consent Form
  4. Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
  5. Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:

    1. Abdominal aortic aneurysm >5.0 cm in diameter,
    2. Aneurysm that has increased in size by 0.5 cm in last 6 months,
    3. Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment.
  6. Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System.
  7. Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
  8. Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
  9. Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
  10. Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm.
  11. Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
  12. Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm.
  13. Patient must be able and willing to comply with all required follow-up exams.

Exclusion Criteria:

  1. Patient has a dissecting aneurysm.
  2. Patient has an acutely ruptured aneurysm.
  3. Patient has an acute vascular injury.
  4. Patient has need for emergent surgery.
  5. Patient has a known thoracic aortic aneurysm or dissection.
  6. Patient has a mycotic aneurysm or has an active systemic infection..
  7. Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
  8. Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
  9. Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair.
  10. Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
  11. Patient has history of bleeding disorders or refuses blood transfusions.
  12. Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl.
  13. Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
  14. Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol.
  15. Patient has a body habitus that would inhibit X-ray visualization of the aorta
  16. Patient has a limited life expectancy of less than 1 year
  17. Patient is currently participating in an investigational device or drug clinical trial.
  18. Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Jiný: Ovation Abdominal Stent Graft System
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
Endovascular implant of Abdominal Aortic Aneurysm Stent Graft

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
Časové okno: 30-Days
30-Days

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Vrchní vyšetřovatel: Francisco Valdes, MD, Pontificia Universidad Catolica de Chile

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Užitečné odkazy

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. listopadu 2009

Primární dokončení (Aktuální)

3. března 2011

Dokončení studie (Aktuální)

3. února 2016

Termíny zápisu do studia

První předloženo

4. března 2010

První předloženo, které splnilo kritéria kontroly kvality

5. března 2010

První zveřejněno (Odhad)

8. března 2010

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

4. června 2021

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

3. června 2021

Naposledy ověřeno

1. června 2021

Více informací

Termíny související s touto studií

Klíčová slova

Další identifikační čísla studie

  • 771-0002

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Ovation Abdominal Stent Graft System