Light microscopy, which is based on century-old technology, remains a key indicator in drug efficacy testing performed in the context of clinical trials for monitoring existing antimalarial drugs or in the context of regulatory clinical trials for registration of new drugs. It is one of the main diagnostic methods for malaria diagnosis in general, as in an ideal setting it can provide low-cost accurate diagnosis, determine the density of parasites in the blood, and accurately differentiate between different malaria parasite species, characteristics vital to the implementation of global plans for drug efficacy monitoring. Malaria rapid tests (RDTs), while useful for rapid diagnosis and case management, do not provide information on the parasite density nor the species differentiation necessary for research and drug efficacy assessment. Microscopy therefore retains key advantages over a number of newer technologies, but its reliability is severely impeded by dependence on high technical competence of the human operators as well as availability of high quality equipment and reagents. Recent studies have demonstrated frequent poor specificity and sensitivity associated with manual microscopy diagnostics in operational conditions. These drawbacks constitute a major limiting factor to effective monitoring and preservation of vital anti-malarial medicines.

Advances in digital microscopy performance and affordability have now opened the door to potentially significant improvements in the performance of malaria microscopy, overcoming serious deficiencies in current drug efficacy assessment, and more broadly in malaria diagnosis and management. Global Good (GG)/Intellectual Ventures Laboratory (IVL) sponsored by the Global Good Fund, has developed a microscope prototype consisting of low cost components to scan and capture images from Giemsa-stained thick blood films on slides. The captured images are analyzed with custom image analysis software developed at GG/IVL, using algorithms that are designed for automatic malaria diagnosis, without user input. Versions of a prototype of the device were first tested in field settings in Thailand in 2014-2015 at clinics operated by the Shoklo Malaria Research Unit (SMRU) and then again in 2016-2017. When compared to expert microscopy at SMRU, the performance of the device with respect to diagnostic sensitivity (87.8%), species identification (85.6% species correctly identified) and parasite density estimation (44% of estimates within +/-25% of reference microscopy result) corresponded to WHO Competence Level 2. The device and the accompanying image analysis algorithms have since been further developed and a new, third version of the prototype is now available for testing in diverse settings with varying malaria prevalence and user expertise.

Panoramica dello studio

Stato

Completato

Condizioni

Descrizione dettagliata

The primary purpose of this evaluation is to quantify the diagnostic performance of the EasyScan Go prototype in various field settings. The performance of the EasyScan Go prototype will be assessed by scanning of negative and positive slides with the EasyScan Go and comparing the results with expert microscopy. Plasmodium genus- and species-specific PCR will also be performed on samples collected at some sites as an additional confirmatory test for the detection of malaria parasites and their species if present. Testing by microscopy and EasyScan Go will be performed in field clinic settings on Giemsa-stained slides prepared from febrile patient blood collected from a finger-prick. Further work will be undertaken at the WWARN laboratory in Bangkok for data analyses and for quality assurance.

Funder: Intellectual Ventures Lab/Global Good (2018) Sponser: University of Oxford Grant refernce number:The Global Good Fund I, LLC PA No.5

Tipo di studio

Osservativo

Iscrizione (Effettivo)

2250

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Tak
      • Mae Sot, Tak, Tailandia
        • Shoklo Malaria Research Unit

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 6 mesi a 75 anni (Bambino, Adulto, Adulto più anziano)

Accetta volontari sani

N/A

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione di probabilità

Popolazione di studio

The multi-centric evaluation is currently planned for implementation at relatively few sites/countries and the primary criteria for the selection of sites will be based on operational feasibility of the project, i.e., availability of resources to perform the study procedures, adequate expected numbers of malaria positive cases, etc.

Potential sites in Senegal, Kenya, Tanzania, Uganda, Congo, South Africa, Burkina Faso, Brazil, Thailand, Indonesia, Bangladesh, Myanmar and Cambodia are being considered for the study.

A minimum of 80 malaria cases confirmed by expert microscopy and a minimum of 80 malaria-negative cases per study site.

Descrizione

Inclusion Criteria:

  • Male or female subjects, age ≥ 6 months to 75 years
  • Febrile at presentation or history of fever in the past 48 hours (≥ 37.5 ºC) and no other obvious diagnosis or cause for fever, warranting malaria investigation under routine clinical practice.
  • Individual informed assent/consent obtained

Exclusion Criteria:

- Signs of severe malaria as defined by WHO

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
Diagnostic sensitivity for malaria parasite detection
Lasso di tempo: 6 months
6 months
Diagnostic specificity for malaria parasite detection
Lasso di tempo: 6 months
6 months
Bland-Altman plots for parasite density estimation
Lasso di tempo: 6 months
6 months
Kappa statistic for parasite species identification
Lasso di tempo: 6 months
6 months

Misure di risultato secondarie

Misura del risultato
Lasso di tempo
Reliability (comparison between 2 devices and repeat reads)
Lasso di tempo: 6 months
6 months
Cost-effectiveness as compared with routine methods
Lasso di tempo: 6 months
6 months
Prevalence of parasite genetic markers of resistance to antimalarials by location and time period
Lasso di tempo: 6 months
6 months
Prevalence of parasites carrying deletions of pfhrp2/3 genes by location and time period
Lasso di tempo: 6 months
6 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

25 giugno 2018

Completamento primario (Effettivo)

31 ottobre 2019

Completamento dello studio (Effettivo)

30 giugno 2020

Date di iscrizione allo studio

Primo inviato

18 aprile 2018

Primo inviato che soddisfa i criteri di controllo qualità

18 aprile 2018

Primo Inserito (Effettivo)

1 maggio 2018

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

3 settembre 2020

Ultimo aggiornamento inviato che soddisfa i criteri QC

1 settembre 2020

Ultimo verificato

1 settembre 2020

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • MAL18002

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi