- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT03543488
Neuromusuclar Adaptations in the Rheumatoid Arthritis Disease
Neuromusuclar Responses and Functional Outcomes in Middle-aged Women With Rheumatoid Arthritis.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Effettivo)
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- RA patients with a class I and II RA diagnosis according to the American Rheumatism Association's 1987 revised criteria, were recruited from a university hospital's rheumatology clinic.
Exclusion Criteria:
- presence of any cardiovascular, neuromuscular and metabolic diseases or severe limitations in mobility
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Rheumatoid Arthritis Patients
Forty women (range 25-75 years), with a class I and II RA diagnosis according to the American Rheumatism Association's 1987 revised criteria, were recruited from a university hospital's rheumatology clinic.
Exclusion criteria included the presence of any cardiovascular, neuromuscular and metabolic diseases or severe limitations in mobility.
Five patients were excluded for not attending the inclusion criteria, leading to a final number of 35 RA patients.
|
The Timed Up and Go test; Maximal knee-extensor muscle strength (isometric and concentric tests) was measured with a Biodex System 3 dynamometer; A B-mode ultrasonography system with a linear-array probe (60 mm, 7.5 MHz) was used to determine VL and RF muscle thickness, pennation angle, fascicle length and tendon CSA. Measurements were obtained with the volunteer seated in the dynamometer, during isometric contraction at 90° of knee flexion. An 8-channel EMG system was synchronized with the dynamometer through a Windaq data acquisition system and used to evaluate the vastus lateralis and rectus femoris electrical activity during isometric knee-extensor tests. |
|
Healthy Women
Thirty-five healthy women, age- and body size-matched to the RA patients, were recruited as controls (CG).
|
The Timed Up and Go test; Maximal knee-extensor muscle strength (isometric and concentric tests) was measured with a Biodex System 3 dynamometer; A B-mode ultrasonography system with a linear-array probe (60 mm, 7.5 MHz) was used to determine VL and RF muscle thickness, pennation angle, fascicle length and tendon CSA. Measurements were obtained with the volunteer seated in the dynamometer, during isometric contraction at 90° of knee flexion. An 8-channel EMG system was synchronized with the dynamometer through a Windaq data acquisition system and used to evaluate the vastus lateralis and rectus femoris electrical activity during isometric knee-extensor tests. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Knee-Extensor Muscular Strength
Lasso di tempo: Only one day.
|
Maximal knee-extensor muscle strength (isometric and concentric tests), in different angles and velocities were measured with a Biodex System 3 dynamometer (Biodex Medical Systems, Shirley, NY, USA).
A 2-min interval was observed between contractions.
We used the peak torque of each maximal test to analysis.
|
Only one day.
|
|
Muscle architecture and tendon parameters
Lasso di tempo: Only one day.
|
An ultrasonography system was used to determine VL and RF muscle thickness, pennation angle and fascicle length.
Muscle architecture measurements were obtained with the volunteer seated in the dynamometer, during isometric contraction at 90° of knee flexion.
Muscle thickness was considered the distance between deep and superficial aponeuroses.
The best fascicle in each image was used for pennation angle and fascicle length analysis.
Pennation angle was calculated as the angle between the muscle fascicle and the deep aponeurosis, whereas fascicle length was measured as the length of the fascicular path between the two aponeuroses.
Furthermore, patellar tendon cross-section area was measured with probe perpendicular to tendon during isometric contractions.
|
Only one day.
|
|
Functional Capacity
Lasso di tempo: Only one day.
|
Timed Up and Go test
|
Only one day.
|
|
Quadriceps muscle activation
Lasso di tempo: Only one day.
|
Vastus Lateralis and Rectus Femoris muscle activation during strength tests
|
Only one day.
|
Collaboratori e investigatori
Collaboratori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
- Processi patologici
- Malattie del sistema nervoso
- Malattie del sistema immunitario
- Malattie autoimmuni
- Manifestazioni neurologiche
- Malattie articolari
- Malattie muscoloscheletriche
- Malattie reumatiche
- Malattie del tessuto connettivo
- Malattie muscolari
- Manifestazioni neuromuscolari
- Artrite
- Artrite, reumatoide
- Debolezza muscolare
Altri numeri di identificazione dello studio
- 09634
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .