Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Investigation of Substrates Associated With the Recurrence of Atrial Fibrillation After PV Cryoablation (SubstrateAF)

The two main mechanisms for atrial fibrillation (AF) recurrence after cryoablation include Pulmonary vein (PV) reconnection and the presence of non-PV associated arrhythmic focuses. The aim of this study is to investigate the prevalence of each mechanism and if biomarkers may be used to predict of these events.

Eighty patients with paroxysmal or persistent AF will undergo PV isolation with cryoablation followed by loop recorder implantation. Patients in whom atrial tachyarrhythmias recur during 12 months follow-up (outside of the 3-month post procedure blanking window) will be offered a second electrophysiology study (EP) study to assess PV isolation and non-PV focuses and further ablation performed as required.

At baseline blood samples will be taken to investigate the correlation between specific biomarkers and both the incidence and type of recurrence. The correlation between recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and elevated baseline levels of NT-ProBNP, CRP, TNF, MMP1 will be pre-specified.

40 consecutive patients will have a biopsy taken from the intraventricular and interatrial septum to investigate the correlation between myocardial inflammation, the presence of fibrosis and recurrence of atrial tachyarrhythmias. Correlation between biomarkers of inflammation and biopsy-proven myocardial inflammation or fibrosis will be assessed.

Panoramica dello studio

Descrizione dettagliata

The two main mechanisms for atrial fibrillation (AF) recurrence after cryoablation include Pulmonary vein (PV) reconnection and the presence of non-PV associated arrhythmic focuses. The aim of this study is to investigate the prevalence of each mechanism and if biomarkers may be used to predict these events.

Eighty patients with paroxysmal or persistent AF will undergo PV isolation with cryoablation followed by loop recorder implantation. Patients in whom atrial tachyarrhythmias recur during 12 months follow-up (outside of the 3-month post procedure blanking window) will be offered a second EP study to assess PV isolation and non-PV focuses and further ablation performed as required. Recurrence will be defined as an episode of atrial tachyarrhythmia (AF, atypical atrial flutter, or atrial tachycardia) on loop recorder with a duration greater than 30 seconds or ECG document atrial tachyarrhythmia. The incidence of atrial tachyarrhythmia recurrence, and its association with symptoms after the index PV cryoballoon isolation, will be assessed.

At baseline blood samples will be taken to assess levels of N-terminal pro brain natriuretic peptide (NT-proBNP), High-sensitivity C-reactive protein (high-sensitive CRP), Tumor Necrosis Factor (TNF), Interleukin 1 beta (IL1B), Fatty acid binding protein (FABP), Matrix metalloproteinase-1 (MMP1), Matrix metalloproteinase-3 (MMP3), Matrix metalloproteinase-9 (MMP9), Transforming growth factor beta 1 (TGF-beta1), Tissue inhibitor of metalloproteinases 1 (TIMP-1), Fibroblast growth factor 9 (FGF-9). Correlation between recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and elevated baseline levels of NT-ProBNP, CRP, TNF, MMP1 will be pre-specified. We will look with receiver operating characteristic (ROC) curve analysis the level of biomarkers which predict recurrence of atrial tachyarrhythmias with the best ratio between sensitivity and specificity.

40 consecutive patients will have a biopsy taken from the intraventricular and interatrial septum to investigate the correlation between myocardial inflammation, the presence of fibrosis and recurrence of atrial tachyarrhythmias. Correlation between biomarkers of inflammation and biopsy-proven myocardial inflammation or fibrosis will be assessed.

Tipo di studio

Osservativo

Iscrizione (Effettivo)

100

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Moscow, Federazione Russa, 101990
        • National Research Center for Preventive Medicine

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 80 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Patients 18-80 years old with symptomatic paroxismal or persistant atrial fibrillation (EHRA scale 2b-4)

Descrizione

Inclusion Criteria:

• Patient with paroxysmal/persistent atrial fibrillation (EHRA scale 2b-4)

Exclusion Criteria:

  • prior interventions for AF
  • permanent AF
  • contraindications to oral anticoagulation or heparin
  • chronic kidney disease requiring dialysis
  • untreated hypo- or hyperthyroidism
  • breast feeding
  • pregnancy
  • chronic kidney disease requiring dialysis
  • decompensated heart failure
  • stroke within the last 3 months
  • myocardial infarction within the last 3 months
  • Percutaneous coronary intervention or Coronary Artery Bypass Grafting within the last 3 months
  • active myocarditis
  • artificial valve replacement surgery
  • severe mitral or aortic stenosis
  • coronary artery disease requiring revascularization
  • heart transplant

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Atrial tachyarrhythmia recurrence
Lasso di tempo: 1 year
Atrial tachyarrhythmias recurrence by ECG, Holter monitoring or loop recorder after 3 months of blanking period
1 year

Misure di risultato secondarie

Misura del risultato
Lasso di tempo
The prevalence of PV reconnection and non-PV focuses as substrate of atrial tachyarrhythmia after cryoablation
Lasso di tempo: 1 year
1 year
The difference in baseline NT-ProBNP levels between those patients with recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and those without at 12 months
Lasso di tempo: 1 year
1 year
The difference in baseline CRP levels between those patients with recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and those without at 12 months
Lasso di tempo: 1 year
1 year
The difference in baseline TNF levels between those patients with recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and those without at 12 months
Lasso di tempo: 1 year
1 year
The difference in baseline MMP1 levels between those patients with recurrence of atrial tachyarrhythmias due to non-PV associated arrhythmic focuses and those without at 12 months
Lasso di tempo: 1 year
1 year
The difference in baseline NT-ProBNP levels between those patients with recurrence of atrial tachyarrhythmias and those without at 12 months
Lasso di tempo: 1 year
1 year

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

3 aprile 2017

Completamento primario (Effettivo)

30 ottobre 2019

Completamento dello studio (Effettivo)

30 ottobre 2019

Date di iscrizione allo studio

Primo inviato

2 luglio 2018

Primo inviato che soddisfa i criteri di controllo qualità

2 luglio 2018

Primo Inserito (Effettivo)

16 luglio 2018

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 gennaio 2020

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 gennaio 2020

Ultimo verificato

1 gennaio 2020

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi