- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT04984135
DCB Angioplasty for Coronary Lesions: an OCT Analysis
Drug-coated Balloon Angioplasty for De-novo or in-Stent Restenotic Coronary Lesions: an Optical Coherence Tomography Analysis
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
The paclitaxel drug-coated balloon (DCB) is an emerging device in percutaneous coronary intervention (PCI); it allows a rapid local release of an anti-restenotic drug without the use of a durable polymer or metal scaffold. The DCB has been proven to be effective with paclitaxel in preclinical trials and in clinical practice for the treatment of coronary lesions such as in-stent restenosis (ISR), de novo and bifurcation lesions. Optical coherence tomography (OCT) is an intravascular imaging modality that has higher resolution than intravascular ultrasound. Excellent contrast among lumen, vessel, and stent in OCT images allows accurate measurement of lumen and lesion. However, only a few studies have investigated the effect of DCB on the intimal lumen in the acute phase and during the follow-up using optical coherence tomography (OCT). In this study, the investigators preformed OCT before and after DCB treatment, as well as at 6 months of follow-up, to assess the tissue characterization.
Demographic, angiographic, and procedural data were collected. Participants were followed up with coronary angiography and OCT for at least 6-9 months, combined with OCT to analyze qualitative analysis of changes in plaque characterization, and late lumen loss. The participants were followed up for long-term clinical events (including cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization).
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Liaoning
-
Dalian, Liaoning, Cina, 116011
- The First Affiliated Hospital of Dalian Medical University
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Coronary angiography shows that at least one coronary artery has a diameter stenosis >70% (left main stem diameter stenosis>50%)
- Stable or unstable angina
- Availability for follow-up for up to 12 months
Exclusion Criteria:
- Acute myocardial infarction within 48 hours
- Severe calcified lesions
- Unable to tolerate dual antiplatelet treatment (DAPT)
- Severe abnormal hematopoietic system, such as platelet count of < 100×109/L or > 700×109/L and white blood cell count of < 3×109/L
- Active bleeding or bleeding tendency
- Severe coexisting conditions, such as severe renal insufficiency (GFR < 60 ml/min•1.73m2), severe hepatic dysfunction [elevated ALT (glutamicpyruvic transaminase) or AST (glutamic-oxal acetic transaminase) level by more than three-fold of the normal limitation], acute or chronic heart failure (NYHA III-IV), acute infectious diseases, immune disorders, malignancy, etc.
- Life expectancy < 12 months
- Pregnancy or planning pregnancy
- Drug allergies or contraindications to aspirin, clopidogrel, ticagrelor, statins, contract, anticoagulant, stent, etc.
- Participation or planning to participate in another clinical trial during the same period
- Refusal to comply with the study protocol
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Enrolled patients
Patients fulfilling the study criteria were included.
|
All patients were treated with a loading dose of clopidogrel 300 or 600 mg before the procedure followed by maintenance clopidogrel 75 mg daily for 6 months.
100 U/ kg of unfractionated heparin was injected intravenously to maintain an activated clotting time ≥ 250 s during the procedure.
For DCB treatment, the patient underwent predilation with an optimal-sized balloon (non-compliant balloon or cutting balloon) based on angiography (balloon-to-vessel ratio of 1.0), with the standard balloon shorter than the intended DCB size.
The DCB was sized at 1:1 balloon-to-vessel ratio, delivered rapidly (median of 15 s) and inflated at nominal pressure for 60 s.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
In-segment late lumen loss
Lasso di tempo: 6 months
|
Changes to lumen area assessed with the use of OCT
|
6 months
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Target lesion failure
Lasso di tempo: 6 months
|
The secondary endpoint was the incidence of target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization (TLR) at 6 months.
|
6 months
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Lei Guo, MD, The First Affiliated Hospital of Dalian Medical University
Pubblicazioni e link utili
Pubblicazioni generali
- Liu Y, Zhang YJ, Deng LX, Yin ZY, Hu T, Wang Q, Li Y, Li JY, Guo WY, Mou FJ, Tao L. 12-Month clinical results of drug-coated balloons for de novo coronary lesion in vessels exceeding 3.0 mm. Int J Cardiovasc Imaging. 2019 Apr;35(4):579-586. doi: 10.1007/s10554-018-1505-z. Epub 2019 Mar 30.
- Rissanen TT, Uskela S, Eranen J, Mantyla P, Olli A, Romppanen H, Siljander A, Pietila M, Minkkinen MJ, Tervo J, Karkkainen JM; DEBUT trial investigators. Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial. Lancet. 2019 Jul 20;394(10194):230-239. doi: 10.1016/S0140-6736(19)31126-2. Epub 2019 Jun 13. Erratum In: Lancet. 2019 Jul 20;394(10194):218.
- Tada T, Kadota K, Hosogi S, Miyake K, Ohya M, Amano H, Izawa Y, Kanazawa T, Kubo S, Ichinohe T, Hyoudou Y, Hayakawa Y, Sabbah MM, Otsuru S, Hasegawa D, Habara S, Tanaka H, Fuku Y, Katoh H, Goto T, Mitsudo K. Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation. Eur Heart J Cardiovasc Imaging. 2015 Oct;16(10):1101-11. doi: 10.1093/ehjci/jev031. Epub 2015 Mar 9.
- Miura K, Tada T, Habara S, Kuwayama A, Shimada T, Ohya M, Murai R, Amano H, Kubo S, Otsuru S, Tanaka H, Fuku Y, Goto T, Kadota K. Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis. Circ J. 2018 Oct 25;82(11):2820-2828. doi: 10.1253/circj.CJ-18-0464. Epub 2018 Aug 30.
- Fukushima T, Ashikaga T, Yoshikawa S, Hatano Y, Ueshima D, Yamamoto T, Yasuhiro M, Isobe M. Effect of drug-coated balloon on stent restenosis, neointimal proliferation, and coronary dissection: an optical coherence tomography analysis. Coron Artery Dis. 2018 Jan;29(1):39-45. doi: 10.1097/MCA.0000000000000552.
- de la Torre Hernandez JM, Garcia Camarero T, Lozano Ruiz-Poveda F, Urbano-Carrillo CA, Sanchez Perez I, Cano-Garcia M, Saez R, Andres Morist A, Molina E, Pinar E, Torres A, Lezcano EJ, Gutierrez H, Arnold RJ, Zueco J. Angiography and Optical Coherence Tomography Assessment of the Drug-Coated Balloon ESSENTIAL for the Treatment of In-Stent Restenosis. Cardiovasc Revasc Med. 2020 Apr;21(4):508-513. doi: 10.1016/j.carrev.2019.07.021. Epub 2019 Jul 23.
- Her AY, Shin ES, Chung JH, Kim YH, Garg S, Lee JM, Doh JH, Nam CW, Koo BK. Plaque modification and stabilization after paclitaxel-coated balloon treatment for de novo coronary lesions. Heart Vessels. 2019 Jul;34(7):1113-1121. doi: 10.1007/s00380-019-01346-9. Epub 2019 Jan 30.
- Sogabe K, Koide M, Fukui K, Kato Y, Kitajima H, Akabame S, Zen K, Nakamura T, Matoba S. Optical coherence tomography analysis of late lumen enlargement after paclitaxel-coated balloon angioplasty for de-novo coronary artery disease. Catheter Cardiovasc Interv. 2021 Jul 1;98(1):E35-E42. doi: 10.1002/ccd.29435. Epub 2020 Dec 28.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- YJ-KY-FB-2021-09
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .