- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07855393
Surface Topography and Radiographic Spinal Damage in Radiographic Axial Spondyloarthritis
Association Between Static Spinal Posture Assessed by Surface Topography (DIERS) and Radiographic Structural Damage (mSASSS) in Radiographic Axial Spondyloarthritis: A Cross-Sectional Study
Radiographic axial spondyloarthritis (r-axSpA) causes progressive structural damage of the spine, conventionally quantified on lateral cervical and lumbar radiographs using the modified Stoke Ankylosing Spondylitis Spine Score (mSASSS). Repeated radiography entails cumulative radiation exposure, substantial inter-reader variability and low sensitivity in early disease. DIERS Formetric 4D surface topography provides radiation-free three-dimensional modelling of the spine and pelvis. The association between sagittal balance and structural damage has been demonstrated with a radiation-based system (EOS), but whether a radiation-free topographic method reflects the same association has not been investigated.
This single-centre, cross-sectional observational study will enrol 53 adults with r-axSpA fulfilling the ASAS criteria with radiographic sacroiliitis according to the modified New York criteria. At a single study visit, static DIERS Formetric 4D measurements, chest expansion, BASMI, BASDAI, BASFI and ASDAS-CRP are obtained. mSASSS is scored by two independent readers, blinded to clinical and topographic data, on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are performed for the study. The primary analysis is the correlation between total mSASSS and the DIERS fleche cervicale (cervical sagittal anterior displacement).
Panoramica dello studio
Stato
Intervento / Trattamento
Descrizione dettagliata
Design: single-centre, cross-sectional, non-interventional correlation study in a single patient group; no control group. All participant data are collected in one assessment session lasting approximately 45 to 60 minutes.
Measurements: (a) demographic and anthropometric data; (b) disease duration, age at symptom onset, comorbidities, extra-articular involvement (uveitis, inflammatory bowel disease, psoriasis), HLA-B27 status, current medication category; (c) radiographic sacroiliitis grade according to the modified New York criteria and mSASSS (range 0 to 72), scored independently by two blinded readers with inter-reader agreement reported as the intraclass correlation coefficient; (d) chest expansion; (e) BASDAI, BASFI and ASDAS-CRP, the latter using routine C-reactive protein values with no additional blood sampling; (f) BASMI total score and its five components; (g) DIERS Formetric 4D static parameters: fleche cervicale (cervical sagittal anterior displacement, mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).
Statistical analysis: distribution is assessed with the Shapiro-Wilk test. The primary analysis is a Pearson or Spearman correlation between total mSASSS and fleche cervicale, reported with effect size and 95% confidence interval, followed by multiple linear regression adjusted for age and disease duration. Secondary analyses comprise correlations of DIERS parameters with clinical indices and an exploratory receiver operating characteristic analysis of the ability of DIERS sagittal parameters to predict prespecified mSASSS thresholds. The Benjamini-Hochberg procedure is applied to correct for multiple comparisons. Significance is set at p<0.05. Analyses are performed with IBM SPSS version 23 or later.
Sample size: calculated with G*Power 3.1.9 for a bivariate normal correlation model, two-tailed, rho H0 = 0, expected effect size r = 0.40, alpha = 0.05 and power = 0.85, giving a required sample of 53 participants (actual power 0.857). The effect size was set conservatively at r = 0.40 rather than the r = 0.61 reported by Wanders et al.
(2005) for occiput-to-wall distance versus mSASSS, because DIERS parameters are not identical to clinical mobility measures.
Reporting follows the STROBE statement.
Tipo di studio
Iscrizione (Stimato)
Contatti e Sedi
Contatto studio
- Nome: Seyma Alkan, MD
- Numero di telefono: +90 538 337 97 91
- Email: symalkan@gmail.com
Backup dei contatti dello studio
- Nome: Yasemin Tombak Yildizkan, MD
- Numero di telefono: +90 505 402 97 63
- Email: yasemintombak@hotmail.com
Luoghi di studio
-
-
Yenimahalle
-
Ankara, Yenimahalle, Turchia (Türkiye), 06560
- Reclutamento
- Ankara Etlik City Hospital, Department of Physical Medicine and Rehabilitation
-
Contatto:
- Seyma Alkan, Medical Doctor
- Numero di telefono: +90 5383379791
- Email: symalkan@gmail.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Consecutive patients with radiographic axial spondyloarthritis attending the spondyloarthritis outpatient clinic of the Department of Physical Medicine and Rehabilitation, Ankara Etlik City Hospital.
Descrizione
Inclusion Criteria:
- Age 18 to 65 years
- Diagnosis of radiographic axial spondyloarthritis fulfilling the ASAS criteria, confirmed by radiographic sacroiliitis according to the modified New York criteria
- Able to provide written informed consent and to complete the assessments
- Available lateral cervical and lumbar radiographs obtained within the 12 months preceding the DIERS measurement
Exclusion Criteria:
- Neurological disease affecting balance, posture or gait (for example Parkinson disease, amyotrophic lateral sclerosis, cerebellar or vestibular disorders, history of stroke)
- History of lower extremity joint arthroplasty (hip or knee)
- Orthopaedic conditions affecting posture, balance or gait (ununited fracture, previous spinal or lower extremity surgery)
- Advanced cardiopulmonary disease, active infection or malignancy
- Pregnancy
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: CROSS_SECTIONAL
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
Radiographic axial spondyloarthritis patients
Adults aged 18 to 65 years with radiographic axial spondyloarthritis fulfilling the ASAS classification criteria with radiographic sacroiliitis according to the modified New York criteria, attending the spondyloarthritis outpatient clinic. All participants undergo a single assessment session including static DIERS Formetric 4D surface topography, clinical indices (BASDAI, BASFI, BASMI, ASDAS-CRP) and chest expansion. mSASSS is scored on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are taken. |
Radiation-free three-dimensional assessment of spinal and pelvic surface topography performed once in standing position. No radiation, no contact, no intervention on treatment. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Correlation between total mSASSS and DIERS fleche cervicale
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
Total modified Stoke Ankylosing Spondylitis Spine Score (mSASSS; range 0 to 72, higher scores indicate greater structural damage), calculated as the mean of two independent blinded readers, correlated with fleche cervicale (cervical sagittal anterior displacement, mm) measured by DIERS Formetric 4D surface topography. Reported as a correlation coefficient with magnitude, direction and 95% confidence interval. |
Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Correlation between total mSASSS and other DIERS Formetric static parameters
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
Total mSASSS (range 0 to 72, higher scores indicate greater structural damage) correlated with the remaining DIERS Formetric 4D static parameters: sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical depth distance (mm), lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). Reported as correlation coefficients with 95% confidence intervals. |
Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
|
Correlation between DIERS sagittal parameters and BASDAI
Lasso di tempo: Single assessment session (Day 1)
|
Bath Ankylosing Spondylitis Disease Activity Index (range 0 to 10, higher scores indicate greater disease activity) correlated with DIERS sagittal parameters. |
Single assessment session (Day 1)
|
|
Correlation between DIERS sagittal parameters and BASFI
Lasso di tempo: Single assessment session (Day 1)
|
Bath Ankylosing Spondylitis Functional Index (range 0 to 10, higher scores indicate worse physical function) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). |
Single assessment session (Day 1)
|
|
Correlation between DIERS sagittal parameters and BASMI
Lasso di tempo: Single assessment session (Day 1)
|
Bath Ankylosing Spondylitis Metrology Index (range 0 to 10, higher scores indicate worse spinal mobility) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). |
Single assessment session (Day 1)
|
|
Correlation between DIERS sagittal parameters and ASDAS-CRP
Lasso di tempo: Single assessment session (Day 1)
|
Ankylosing Spondylitis Disease Activity Score with C-reactive protein (higher scores indicate greater disease activity) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). |
Single assessment session (Day 1)
|
|
Correlation between DIERS sagittal parameters and chest expansion
Lasso di tempo: Single assessment session (Day 1)
|
Chest expansion measured in centimetres correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). |
Single assessment session (Day 1)
|
|
Discriminative performance of DIERS sagittal parameters for mSASSS thresholds
Lasso di tempo: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
Exploratory receiver operating characteristic analysis of DIERS Formetric 4D sagittal parameters for discriminating prespecified total mSASSS thresholds. Reported as area under the curve with 95% confidence interval, sensitivity and specificity. |
Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Ajda Bal, Professor of Physical Medicine and Rehabilitation
Pubblicazioni e link utili
Pubblicazioni generali
- Turk E, Yurdakul FG, Guler T, Bodur H. Posture, balance and gait in axial spondyloarthritis: a case-control study. Rheumatol Int. 2024 Nov;44(11):2527-2538. doi: 10.1007/s00296-024-05710-5. Epub 2024 Sep 4.
- Oliveira TL, Silva FD, Filho AGO, Nico MAC, Fernandes ARC, Ramiro S, Pinheiro MM. Relationship between spinal structural damage and sagittal balance in axial spondyloarthritis: Is the thoracic spine the starting point? Semin Arthritis Rheum. 2024 Apr;65:152415. doi: 10.1016/j.semarthrit.2024.152415. Epub 2024 Feb 7.
- Wanders A, Landewe R, Dougados M, Mielants H, van der Linden S, van der Heijde D. Association between radiographic damage of the spine and spinal mobility for individual patients with ankylosing spondylitis: can assessment of spinal mobility be a proxy for radiographic evaluation? Ann Rheum Dis. 2005 Jul;64(7):988-94. doi: 10.1136/ard.2004.029728.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- AEŞH-BADEK1-2026-048
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Individual participant data will not be shared. According to the approved protocol, research data are accessible only to the investigators. Aggregate results will be published.
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .