Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Surface Topography and Radiographic Spinal Damage in Radiographic Axial Spondyloarthritis

28 сентября 2026 г. обновлено: Seyma Alkan, Ankara Etlik City Hospital

Association Between Static Spinal Posture Assessed by Surface Topography (DIERS) and Radiographic Structural Damage (mSASSS) in Radiographic Axial Spondyloarthritis: A Cross-Sectional Study

Radiographic axial spondyloarthritis (r-axSpA) causes progressive structural damage of the spine, conventionally quantified on lateral cervical and lumbar radiographs using the modified Stoke Ankylosing Spondylitis Spine Score (mSASSS). Repeated radiography entails cumulative radiation exposure, substantial inter-reader variability and low sensitivity in early disease. DIERS Formetric 4D surface topography provides radiation-free three-dimensional modelling of the spine and pelvis. The association between sagittal balance and structural damage has been demonstrated with a radiation-based system (EOS), but whether a radiation-free topographic method reflects the same association has not been investigated.

This single-centre, cross-sectional observational study will enrol 53 adults with r-axSpA fulfilling the ASAS criteria with radiographic sacroiliitis according to the modified New York criteria. At a single study visit, static DIERS Formetric 4D measurements, chest expansion, BASMI, BASDAI, BASFI and ASDAS-CRP are obtained. mSASSS is scored by two independent readers, blinded to clinical and topographic data, on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are performed for the study. The primary analysis is the correlation between total mSASSS and the DIERS fleche cervicale (cervical sagittal anterior displacement).

Обзор исследования

Подробное описание

Design: single-centre, cross-sectional, non-interventional correlation study in a single patient group; no control group. All participant data are collected in one assessment session lasting approximately 45 to 60 minutes.

Measurements: (a) demographic and anthropometric data; (b) disease duration, age at symptom onset, comorbidities, extra-articular involvement (uveitis, inflammatory bowel disease, psoriasis), HLA-B27 status, current medication category; (c) radiographic sacroiliitis grade according to the modified New York criteria and mSASSS (range 0 to 72), scored independently by two blinded readers with inter-reader agreement reported as the intraclass correlation coefficient; (d) chest expansion; (e) BASDAI, BASFI and ASDAS-CRP, the latter using routine C-reactive protein values with no additional blood sampling; (f) BASMI total score and its five components; (g) DIERS Formetric 4D static parameters: fleche cervicale (cervical sagittal anterior displacement, mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Statistical analysis: distribution is assessed with the Shapiro-Wilk test. The primary analysis is a Pearson or Spearman correlation between total mSASSS and fleche cervicale, reported with effect size and 95% confidence interval, followed by multiple linear regression adjusted for age and disease duration. Secondary analyses comprise correlations of DIERS parameters with clinical indices and an exploratory receiver operating characteristic analysis of the ability of DIERS sagittal parameters to predict prespecified mSASSS thresholds. The Benjamini-Hochberg procedure is applied to correct for multiple comparisons. Significance is set at p<0.05. Analyses are performed with IBM SPSS version 23 or later.

Sample size: calculated with G*Power 3.1.9 for a bivariate normal correlation model, two-tailed, rho H0 = 0, expected effect size r = 0.40, alpha = 0.05 and power = 0.85, giving a required sample of 53 participants (actual power 0.857). The effect size was set conservatively at r = 0.40 rather than the r = 0.61 reported by Wanders et al.

(2005) for occiput-to-wall distance versus mSASSS, because DIERS parameters are not identical to clinical mobility measures.

Reporting follows the STROBE statement.

Тип исследования

Наблюдательный

Регистрация (Оцененный)

53

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

  • Имя: Seyma Alkan, MD
  • Номер телефона: +90 538 337 97 91
  • Электронная почта: symalkan@gmail.com

Учебное резервное копирование контактов

  • Имя: Yasemin Tombak Yildizkan, MD
  • Номер телефона: +90 505 402 97 63
  • Электронная почта: yasemintombak@hotmail.com

Места учебы

    • Yenimahalle
      • Ankara, Yenimahalle, Турция (Туркие), 06560
        • Рекрутинг
        • Ankara Etlik City Hospital, Department of Physical Medicine and Rehabilitation
        • Контакт:
          • Seyma Alkan, Medical Doctor
          • Номер телефона: +90 5383379791
          • Электронная почта: symalkan@gmail.com

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 18 лет до 65 лет (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Метод выборки

Невероятностная выборка

Исследуемая популяция

Consecutive patients with radiographic axial spondyloarthritis attending the spondyloarthritis outpatient clinic of the Department of Physical Medicine and Rehabilitation, Ankara Etlik City Hospital.

Описание

Inclusion Criteria:

  • Age 18 to 65 years
  • Diagnosis of radiographic axial spondyloarthritis fulfilling the ASAS criteria, confirmed by radiographic sacroiliitis according to the modified New York criteria
  • Able to provide written informed consent and to complete the assessments
  • Available lateral cervical and lumbar radiographs obtained within the 12 months preceding the DIERS measurement

Exclusion Criteria:

  • Neurological disease affecting balance, posture or gait (for example Parkinson disease, amyotrophic lateral sclerosis, cerebellar or vestibular disorders, history of stroke)
  • History of lower extremity joint arthroplasty (hip or knee)
  • Orthopaedic conditions affecting posture, balance or gait (ununited fracture, previous spinal or lower extremity surgery)
  • Advanced cardiopulmonary disease, active infection or malignancy
  • Pregnancy

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Наблюдательные модели: COHORT
  • Временные перспективы: CROSS_SECTIONAL

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
Radiographic axial spondyloarthritis patients

Adults aged 18 to 65 years with radiographic axial spondyloarthritis fulfilling the ASAS classification criteria with radiographic sacroiliitis according to the modified New York criteria, attending the spondyloarthritis outpatient clinic. All participants undergo a single assessment session including static DIERS Formetric 4D surface topography, clinical indices (BASDAI, BASFI, BASMI, ASDAS-CRP) and chest expansion. mSASSS is scored on existing lateral cervical and lumbar radiographs obtained within the preceding 12 months; no additional radiographs are taken.

Radiation-free three-dimensional assessment of spinal and pelvic surface topography performed once in standing position. No radiation, no contact, no intervention on treatment.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Correlation between total mSASSS and DIERS fleche cervicale
Временное ограничение: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Total modified Stoke Ankylosing Spondylitis Spine Score (mSASSS; range 0 to 72, higher scores indicate greater structural damage), calculated as the mean of two independent blinded readers, correlated with fleche cervicale (cervical sagittal anterior displacement, mm) measured by DIERS Formetric 4D surface topography. Reported as a correlation coefficient with magnitude, direction and 95% confidence interval.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Correlation between total mSASSS and other DIERS Formetric static parameters
Временное ограничение: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Total mSASSS (range 0 to 72, higher scores indicate greater structural damage) correlated with the remaining DIERS Formetric 4D static parameters: sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical depth distance (mm), lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees). Reported as correlation coefficients with 95% confidence intervals.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment
Correlation between DIERS sagittal parameters and BASDAI
Временное ограничение: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Disease Activity Index (range 0 to 10, higher scores indicate greater disease activity) correlated with DIERS sagittal parameters.

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and BASFI
Временное ограничение: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Functional Index (range 0 to 10, higher scores indicate worse physical function) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and BASMI
Временное ограничение: Single assessment session (Day 1)

Bath Ankylosing Spondylitis Metrology Index (range 0 to 10, higher scores indicate worse spinal mobility) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and ASDAS-CRP
Временное ограничение: Single assessment session (Day 1)

Ankylosing Spondylitis Disease Activity Score with C-reactive protein (higher scores indicate greater disease activity) correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Correlation between DIERS sagittal parameters and chest expansion
Временное ограничение: Single assessment session (Day 1)

Chest expansion measured in centimetres correlated with DIERS Formetric 4D static parameters: fleche cervicale (mm), sagittal imbalance (mm and degrees), coronal imbalance (mm), pelvic obliquity (mm), pelvic torsion (degrees), cervical and lumbar depth distance (mm), kyphotic angle (degrees) and lordotic angle (degrees).

Single assessment session (Day 1)
Discriminative performance of DIERS sagittal parameters for mSASSS thresholds
Временное ограничение: Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Exploratory receiver operating characteristic analysis of DIERS Formetric 4D sagittal parameters for discriminating prespecified total mSASSS thresholds. Reported as area under the curve with 95% confidence interval, sensitivity and specificity.

Single assessment session (Day 1); mSASSS scored on radiographs obtained within the 12 months preceding the assessment

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Следователи

  • Главный следователь: Ajda Bal, Professor of Physical Medicine and Rehabilitation

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

19 сентября 2026 г.

Первичное завершение (Оцененный)

20 июня 2027 г.

Завершение исследования (Оцененный)

20 августа 2027 г.

Даты регистрации исследования

Первый отправленный

28 сентября 2026 г.

Впервые представлено, что соответствует критериям контроля качества

28 сентября 2026 г.

Первый опубликованный (Действительный)

2 октября 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

2 октября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

28 сентября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Описание плана IPD

Individual participant data will not be shared. According to the approved protocol, research data are accessible only to the investigators. Aggregate results will be published.

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться