Catheter Ablation of Atrial Fibrillation Using Hansen Medical Robotic Navigation (Hansen)
Catheter Ablation of Atrial Fibrillation Using Hansen Medical Robotic Navigation - A Randomised Controlled Trial
Atrial fibrillation (AF) affects as many as 1 in 100 people and reduces the quality of life of large numbers of people in the UK and around the world. Catheter ablation is a minimally invasive treatment that has been developed to help eliminate AF. It is a complex procedure to perform so only a few hospitals are able to offer this treatment in the UK. A new technology allows the operator to guide their catheters (thin wires) in the patient by using a robotically steered sheath. This allows accurate and precise navigation that may improve the accuracy and integrity of ablation. We aim to prove whether this technology can make AF ablation easier and more effective.
Substudy: Platelet reactivity and activation in AF, and the impact of curative ablation. Blood and urine samples will be taken pre- and 3 months post ablation to see if platelet reactivity and activation are affected by AF compared to established normal ranges, and whether curative ablation impacts on this.
調査の概要
研究の種類
入学 (実際)
段階
- フェーズ 4
連絡先と場所
研究場所
-
-
-
London、イギリス、EC1A 7BE
- Barts and the London NHS Trust
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- All patients with symptomatic AF planned for catheter ablation.
Exclusion Criteria:
- Age < 18 years
- Previous ablation procedure
- Expected life expectancy < 6 months
- Inability or unwillingness to sign consent
- Pregnancy
- Contraindications for the ablation procedure o Thrombus in the left atrium that fails to resolve with optimal oral anticoagulation therapy
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
他の:manual ablation
|
ablation procedure performed with Hansen robotic navigation system
Ablation will be performed as normal treatment
|
|
実験的:robotic ablation
|
ablation procedure performed with Hansen robotic navigation system
Ablation will be performed as normal treatment
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Single procedure success rate at 12 months
時間枠:12 months
|
12 months
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Complication rates, catheter stability, procedure/fluoroscopy time (and dose), subjectively assessed operator fatigue
時間枠:0-12 months
|
0-12 months
|
|
Platelet substudy: Platelet activation post ablation compared to baseline.
時間枠:3 months
|
3 months
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Ullah W, McLean A, Hunter RJ, Baker V, Richmond L, Cantor EJ, Dhinoja MB, Sporton S, Earley MJ, Schilling RJ. Randomized trial comparing robotic to manual ablation for atrial fibrillation. Heart Rhythm. 2014 Nov;11(11):1862-9. doi: 10.1016/j.hrthm.2014.06.026. Epub 2014 Jun 21.
- Duncan ER, Finlay M, Page SP, Hunter R, Goromonzi F, Richmond L, Baker V, Ginks M, Ezzat V, Dhinoja M, Earley MJ, Sporton S, Schilling RJ. Improved electrogram attenuation during ablation of paroxysmal atrial fibrillation with the Hansen robotic system. Pacing Clin Electrophysiol. 2012 Jun;35(6):730-8. doi: 10.1111/j.1540-8159.2012.03381.x. Epub 2012 Apr 11.
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
catheter ablationの臨床試験
-
Boston Scientific Corporation完了
-
Shanghai MicroPort EP MedTech Co., Ltd.まだ募集していません
-
Pier LambiaseUniversity Hospital Southampton NHS Foundation Trust; The Royal Bournemouth Hospital完了
-
BrosMed Medical Co., LtdCCRF Inc., Beijing, Chinaわからない