Respiratory Physiology Under High Flow Therapy
Respiratory Physiology Measurements Under Transnasal High Flow Therapy in Patients With Tracheostoma After Long Term Ventilation
調査の概要
詳細な説明
Ten patients, who are supplied with a tracheostomy stent (placeholder) for reinsertions after long term ventilation will be treated for a short time during the day with the nasal high flow system AIRVO at different flow rates (15, 30, 45L/min) to estimate possible long term implications of high flow treatment.
Respiration is measured by impedance plethysmography with a calibrated belt system (Respitrace, VIASYS). Pressure and end tidal CO2 concentration is measured inside of the placeholder.
The order of the high flow rates (15, 30, 45L/min) is randomized; each flow rate is measured for 15 minutes. A wash out time of ten minutes is planned after each phase. In this time the patient breathes his individual oxygen flow rate with attention to the oxygen saturation, which should not exceed 96%. Transcutaneous PCO2 and SpO2 is monitored with TOSCA during the study.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
NRW
-
Hagen、NRW、ドイツ、58091
- Helios Klinik Hagen Ambrock
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients in a stable weaning phase after long term ventilation
- Patients supplied with tracheostomy stent (placeholder)
- Patients in stable respiratory situation
Exclusion Criteria:
- Incapable of giving consent
- Any other severe or acute physical illness which requires intensive medical care
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:基礎科学
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:High flow therapy
|
Each patient is treated with nasal high flow at different flow rates (15, 30, 45L/min).
The order of flow rates is randomized.
Each flow rate will be used for 15 minutes.
A wash out time of ten minutes is planned after each phase, during which the patient uses his his individual oxygen flow.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intratracheal pressure conditions
時間枠:2 hours
|
The effects of high flow transnasal insufflation on intratracheal pressure conditions is measured with the Hans Rudolph Inc. pressure amplifier and continuously recorded breath by breath.
|
2 hours
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intratracheal endtidal CO2 concentration
時間枠:2 hours
|
The effects of high flow transnasal insufflation on endtidal CO2 concentration is measured with the AD Instruments gas analyser and continuously recorded breath by breath.
|
2 hours
|
|
Breathing frequency and tidal volume
時間枠:2 hours
|
The effects of high flow transnasal insufflation on breathing frequency and tidal volume is measured with the Viasys Respitrace calibrated belt system and continuously recorded breath by breath.
|
2 hours
|
協力者と研究者
捜査官
- 主任研究者:Georg Nilius, MD、Helios Klinik Hagen Ambrock, Germany
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- Trachea 2.0
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。