Respiratory Physiology Under High Flow Therapy
Respiratory Physiology Measurements Under Transnasal High Flow Therapy in Patients With Tracheostoma After Long Term Ventilation
研究概览
详细说明
Ten patients, who are supplied with a tracheostomy stent (placeholder) for reinsertions after long term ventilation will be treated for a short time during the day with the nasal high flow system AIRVO at different flow rates (15, 30, 45L/min) to estimate possible long term implications of high flow treatment.
Respiration is measured by impedance plethysmography with a calibrated belt system (Respitrace, VIASYS). Pressure and end tidal CO2 concentration is measured inside of the placeholder.
The order of the high flow rates (15, 30, 45L/min) is randomized; each flow rate is measured for 15 minutes. A wash out time of ten minutes is planned after each phase. In this time the patient breathes his individual oxygen flow rate with attention to the oxygen saturation, which should not exceed 96%. Transcutaneous PCO2 and SpO2 is monitored with TOSCA during the study.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
NRW
-
Hagen、NRW、德国、58091
- Helios Klinik Hagen Ambrock
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Patients in a stable weaning phase after long term ventilation
- Patients supplied with tracheostomy stent (placeholder)
- Patients in stable respiratory situation
Exclusion Criteria:
- Incapable of giving consent
- Any other severe or acute physical illness which requires intensive medical care
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:High flow therapy
|
Each patient is treated with nasal high flow at different flow rates (15, 30, 45L/min).
The order of flow rates is randomized.
Each flow rate will be used for 15 minutes.
A wash out time of ten minutes is planned after each phase, during which the patient uses his his individual oxygen flow.
其他名称:
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Intratracheal pressure conditions
大体时间:2 hours
|
The effects of high flow transnasal insufflation on intratracheal pressure conditions is measured with the Hans Rudolph Inc. pressure amplifier and continuously recorded breath by breath.
|
2 hours
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Intratracheal endtidal CO2 concentration
大体时间:2 hours
|
The effects of high flow transnasal insufflation on endtidal CO2 concentration is measured with the AD Instruments gas analyser and continuously recorded breath by breath.
|
2 hours
|
|
Breathing frequency and tidal volume
大体时间:2 hours
|
The effects of high flow transnasal insufflation on breathing frequency and tidal volume is measured with the Viasys Respitrace calibrated belt system and continuously recorded breath by breath.
|
2 hours
|
合作者和调查者
调查人员
- 首席研究员:Georg Nilius, MD、Helios Klinik Hagen Ambrock, Germany
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- Trachea 2.0
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.