Safety and Tolerability of the Ophthalmic Solution PRO-156 in Ophthalmologically Healthy Volunteers.
Phase I Clinical Trial to Assess the Safety and Tolerability of the Ophthalmic Solution PRO-156 Over the Ocular Surface of Ophthalmologically Healthy Volunteers.
調査の概要
詳細な説明
研究の種類
入学 (実際)
段階
- フェーズ 1
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Healthy male and female.
- Age between 18 and 40 years old at screening visit.
- Signed informed consent
Exclusion Criteria:
- Patient with one blind eye.
- Any ocular or systemic condition.
- Visual acuity of 20/100 in any eye.
- Use of ocular or systemic medication.
- Contraindications or sensitivity to any component of the study treatment.
- Contact lens users.
- Ocular surgery within the past 3 months..
- Pregnant, nursing or childbearing potential women who were not using effective contraception.
- Participation in any studies of investigational drugs within 90 days previous to the inclusion.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:PRO-156
Drug: PRO-156 ophthalmic solution One drop of PRO-156 ophthalmic solution administered to each eye, four times a day for 10 days.
|
Drug: PRO-156 ophthalmic solution One drop of PRO-156 ophthalmic solution administered to each eye, four times a day for 10 days.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Visual Acuity (VA)
時間枠:11 days
|
The VA will be evaluated basally, without refractive correction with the Snellen chart. A Snellen chart is placed at a standard distance: 20 ft. At this distance, the symbols on the line representing "normal" acuity subtend. This line, designated 20/20 is the smallest line that a person with normal acuity can read at a distance of 20fs. the scale consists of 11 lines of letters of different size, the size of the letter gives a fractional value according to the visual acuity of the patient, the value is inversely proportional to the visual acuity, if the denominator is greater the visual acuity will be less. Line 1: 20/200 Line 2: 20/100, Line 3: 20/70, line 4: 20/50, line 5: 20/40, Line 6: 20/30, line 7: 20/25, Line 8: 20/20, line 9: 20/15, line 10: 20/13, line 11: 20/10. the results will be expressed as the mean of the denominator of the Snellen scale (scale 20/--) example. 18.5 ± 1.5, that means the final result is 20/18.5 ± 1.5 |
11 days
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intraocular Pressure (IOP)
時間枠:11 days
|
The tension of a healthy eye should be between 10 and 20 millimeters of mercury (mmHg).
In Goldman-type Applying Tonometry, the cornea is flattened, and the intraocular pressure is determined by measuring the force of application and the flattened area.
|
11 days
|
|
Number of Eyes With Epithelial Defects
時間枠:11 days
|
the number of epithelial defects was evaluated by the application of fluorescein, Staining was performed with fluorescein which stained the degenerated cells and the mucus filaments present in the tear film.
|
11 days
|
|
Number of Cases With Adverse Events
時間枠:11 days
|
The presence of adverse events was evaluated by the number of cases.
|
11 days
|
協力者と研究者
捜査官
- 主任研究者:Mauricio Casillas, MD、Independent Clinical Research Center
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- SOPH156-0612/I
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。