Formula Identification (FID) 114657 in Contact Lens Wearers
2016年10月4日 更新者:Alcon Research
Evaluation of a Lubricant Eye Drop on Tear Lipid Layer Thickness in Contact Lens Wearers
The purpose of this study is to evaluate the thickness of the pre-lens tear lipid layer after 2 hours of lens wear with use of FID 114657 compared to saline control.
調査の概要
状態
完了
条件
研究の種類
介入
入学 (実際)
234
段階
- 適用できない
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
18年歳以上 (大人、高齢者)
健康ボランティアの受け入れ
いいえ
受講資格のある性別
全て
説明
Inclusion Criteria:
- Must sign the informed consent form.
- Stable, tear lipid layer thickness ≤ 75 nm without contact lenses.
- Successfully wearing bi-weekly or monthly replacement soft contact lenses in both eyes for a minimum of 5 days/week during the past 2 months prior to Visit 1.
- Vision correctable to 20/25 Snellen (feet) or better at distance with habitual contact lenses at Visit 1.
- Willing to wear lenses 5 days a week, 8 hours a day for at least 2 days during the study.
- Demonstrate symptoms of contact lens discomfort.
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Routinely sleeping in lenses.
- Any active eye inflammation or condition that contraindicates contact lens wear.
- Any systemic diseases that could prevent successful contact lens wear.
- Use of systemic or ocular medications that contraindicate lens wear.
- Fit with only 1 contact lens.
- Unwilling to discontinue the use of cosmetics (such as eyeliner, mascara, or eye shadow) or facial creams on or around the eyelids on Day 1 and Day 14 of the study.
- Women of childbearing potential who are currently pregnant, test positive for pregnancy at Screening visit, breast feeding, or unwilling to use adequate birth control throughout the study.
- Other protocol-defined exclusion criteria may apply.
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:FID 114657
FID 114657 eye drops (10 ml), 1-2 drops instilled in each eye 10 minutes prior to inserting a new pair of habitual contact lenses and after removing them, daily for 2 weeks.
|
Lubricating eye drop for temporary relief of burning and irritation due to dryness of the eye
Commercially marketed biweekly or monthly replacement soft contact lenses as prescribed by eye care practitioner, brand and power
|
|
アクティブコンパレータ:Saline Control
Saline control eye drops (15 ml), 1-2 drops instilled in each eye 10 minutes prior to inserting a new pair of habitual contact lenses and after removing them, daily for 2 weeks.
|
Commercially marketed biweekly or monthly replacement soft contact lenses as prescribed by eye care practitioner, brand and power
Saline eye drops (15 ml)
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean Pre-lens Tear Lipid Layer Thickness After 2 Hours of Lens Wear on Day 1
時間枠:Day 1, after 2 hours of lens wear
|
The pre-lens tear film is the layer of tears located on top of the contact lens (i.e., between the eye lid and the contact lens).
The anterior-most layer of the pre-lens tear film consists of lipids.
Lipid layer thickness (LLT) is measured with the LipiView® Interferometer.
LLT is measured in interferometric color units (ICUs), where 1 ICU reflects about 1 nanometer (nm) lipid layer thickness.
Higher values of LLT indicate a better lubrication of the ocular surface.
A thicker tear lipid layer helps reduce evaporation and is indicative of a more stable tear film.
The right eye only was used for this measure.
|
Day 1, after 2 hours of lens wear
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Mean Comfortable Lens Wear Time (Time Uncomfortable - Time Insertion) at Baseline and Day 14
時間枠:Baseline (Day 0), Day 14
|
At Baseline and on Day 14, comfort was collected through participant questionnaires regarding average and comfortable wear time.
Participants filled in what time of day (over the past three days) they usually inserted their lenses, removed them, and at what time they usually became uncomfortable, or if they remained comfortable all day.
Comfortable wear time was calculated as Time Uncomfortable minus Time Insertion.
The participant rated both eyes together by providing one single rating.
This outcome measure was prespecified for only FID 114657.
|
Baseline (Day 0), Day 14
|
|
Percentage of Participants That Experienced At Least 1 Unit Increase From Baseline Score to Day 14 for Overall Comfort With Lenses
時間枠:Baseline (Day 0), Day 14
|
Overall comfort was rated by the participant on a 10-point scale, where 1=Poor and 10=Excellent, at Day 0 for their habitual lenses and at Day 14 for the lenses worn for the study during use of the assigned drop regimen.
A 1-unit increase indicates improvement.
The participant rated both eyes together by providing one single rating.
|
Baseline (Day 0), Day 14
|
|
Mean Change From Baseline in Comfortable Lens Wear Time (Time Uncomfortable - Time Insertion) to Day 14
時間枠:Baseline (Day 0), Day 14
|
At Baseline and on Day 14, comfort was collected through participant questionnaires regarding average and comfortable wear time.
Participants filled in what time of day (over the past three days) they usually inserted their lenses, removed them, and at what time they usually became uncomfortable, or if they remained comfortable all day.
Comfortable wear time was calculated as Time Uncomfortable minus Time Insertion.
A positive change from Baseline indicates improvement.
The participant rated both eyes together by providing one single rating.
|
Baseline (Day 0), Day 14
|
|
Mean Pre-lens Tear Lipid Layer Thickness After 2 Hours of Lens Wear on Day 14
時間枠:Day 14, after 2 hours of lens wear
|
The pre-lens tear film is the layer of tears located on top of the contact lens (i.e., between the eye lid and the contact lens).
The anterior-most layer of the pre-lens tear film consists of lipids.
Lipid layer thickness (LLT) is measured with the LipiView® Interferometer.
LLT is measured in interferometric color units (ICUs), where 1 ICU reflects about 1 nanometer (nm) lipid layer thickness.
Higher values of LLT indicate a better lubrication of the ocular surface.
A thicker tear lipid layer helps reduce evaporation and is indicative of a more stable tear film.
The right eye only was used for this measure.
|
Day 14, after 2 hours of lens wear
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
スポンサー
捜査官
- スタディディレクター:Clinical Manager, Pharmaceuticals, Global Medical Affairs、Alcon Research
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始
2014年11月1日
一次修了 (実際)
2015年7月1日
研究の完了 (実際)
2015年7月1日
試験登録日
最初に提出
2014年11月14日
QC基準を満たした最初の提出物
2014年11月17日
最初の投稿 (見積もり)
2014年11月18日
学習記録の更新
投稿された最後の更新 (見積もり)
2016年10月6日
QC基準を満たした最後の更新が送信されました
2016年10月4日
最終確認日
2016年8月1日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- LCO242-P001
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。