Formula Identification (FID) 114657 in Contact Lens Wearers
4 octobre 2016 mis à jour par: Alcon Research
Evaluation of a Lubricant Eye Drop on Tear Lipid Layer Thickness in Contact Lens Wearers
The purpose of this study is to evaluate the thickness of the pre-lens tear lipid layer after 2 hours of lens wear with use of FID 114657 compared to saline control.
Aperçu de l'étude
Statut
Complété
Les conditions
Type d'étude
Interventionnel
Inscription (Réel)
234
Phase
- N'est pas applicable
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
18 ans et plus (Adulte, Adulte plus âgé)
Accepte les volontaires sains
Non
Sexes éligibles pour l'étude
Tout
La description
Inclusion Criteria:
- Must sign the informed consent form.
- Stable, tear lipid layer thickness ≤ 75 nm without contact lenses.
- Successfully wearing bi-weekly or monthly replacement soft contact lenses in both eyes for a minimum of 5 days/week during the past 2 months prior to Visit 1.
- Vision correctable to 20/25 Snellen (feet) or better at distance with habitual contact lenses at Visit 1.
- Willing to wear lenses 5 days a week, 8 hours a day for at least 2 days during the study.
- Demonstrate symptoms of contact lens discomfort.
- Other protocol-defined inclusion criteria may apply.
Exclusion Criteria:
- Routinely sleeping in lenses.
- Any active eye inflammation or condition that contraindicates contact lens wear.
- Any systemic diseases that could prevent successful contact lens wear.
- Use of systemic or ocular medications that contraindicate lens wear.
- Fit with only 1 contact lens.
- Unwilling to discontinue the use of cosmetics (such as eyeliner, mascara, or eye shadow) or facial creams on or around the eyelids on Day 1 and Day 14 of the study.
- Women of childbearing potential who are currently pregnant, test positive for pregnancy at Screening visit, breast feeding, or unwilling to use adequate birth control throughout the study.
- Other protocol-defined exclusion criteria may apply.
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
---|---|
Expérimental: FID 114657
FID 114657 eye drops (10 ml), 1-2 drops instilled in each eye 10 minutes prior to inserting a new pair of habitual contact lenses and after removing them, daily for 2 weeks.
|
Lubricating eye drop for temporary relief of burning and irritation due to dryness of the eye
Commercially marketed biweekly or monthly replacement soft contact lenses as prescribed by eye care practitioner, brand and power
|
Comparateur actif: Saline Control
Saline control eye drops (15 ml), 1-2 drops instilled in each eye 10 minutes prior to inserting a new pair of habitual contact lenses and after removing them, daily for 2 weeks.
|
Commercially marketed biweekly or monthly replacement soft contact lenses as prescribed by eye care practitioner, brand and power
Saline eye drops (15 ml)
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Mean Pre-lens Tear Lipid Layer Thickness After 2 Hours of Lens Wear on Day 1
Délai: Day 1, after 2 hours of lens wear
|
The pre-lens tear film is the layer of tears located on top of the contact lens (i.e., between the eye lid and the contact lens).
The anterior-most layer of the pre-lens tear film consists of lipids.
Lipid layer thickness (LLT) is measured with the LipiView® Interferometer.
LLT is measured in interferometric color units (ICUs), where 1 ICU reflects about 1 nanometer (nm) lipid layer thickness.
Higher values of LLT indicate a better lubrication of the ocular surface.
A thicker tear lipid layer helps reduce evaporation and is indicative of a more stable tear film.
The right eye only was used for this measure.
|
Day 1, after 2 hours of lens wear
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Mean Comfortable Lens Wear Time (Time Uncomfortable - Time Insertion) at Baseline and Day 14
Délai: Baseline (Day 0), Day 14
|
At Baseline and on Day 14, comfort was collected through participant questionnaires regarding average and comfortable wear time.
Participants filled in what time of day (over the past three days) they usually inserted their lenses, removed them, and at what time they usually became uncomfortable, or if they remained comfortable all day.
Comfortable wear time was calculated as Time Uncomfortable minus Time Insertion.
The participant rated both eyes together by providing one single rating.
This outcome measure was prespecified for only FID 114657.
|
Baseline (Day 0), Day 14
|
Percentage of Participants That Experienced At Least 1 Unit Increase From Baseline Score to Day 14 for Overall Comfort With Lenses
Délai: Baseline (Day 0), Day 14
|
Overall comfort was rated by the participant on a 10-point scale, where 1=Poor and 10=Excellent, at Day 0 for their habitual lenses and at Day 14 for the lenses worn for the study during use of the assigned drop regimen.
A 1-unit increase indicates improvement.
The participant rated both eyes together by providing one single rating.
|
Baseline (Day 0), Day 14
|
Mean Change From Baseline in Comfortable Lens Wear Time (Time Uncomfortable - Time Insertion) to Day 14
Délai: Baseline (Day 0), Day 14
|
At Baseline and on Day 14, comfort was collected through participant questionnaires regarding average and comfortable wear time.
Participants filled in what time of day (over the past three days) they usually inserted their lenses, removed them, and at what time they usually became uncomfortable, or if they remained comfortable all day.
Comfortable wear time was calculated as Time Uncomfortable minus Time Insertion.
A positive change from Baseline indicates improvement.
The participant rated both eyes together by providing one single rating.
|
Baseline (Day 0), Day 14
|
Mean Pre-lens Tear Lipid Layer Thickness After 2 Hours of Lens Wear on Day 14
Délai: Day 14, after 2 hours of lens wear
|
The pre-lens tear film is the layer of tears located on top of the contact lens (i.e., between the eye lid and the contact lens).
The anterior-most layer of the pre-lens tear film consists of lipids.
Lipid layer thickness (LLT) is measured with the LipiView® Interferometer.
LLT is measured in interferometric color units (ICUs), where 1 ICU reflects about 1 nanometer (nm) lipid layer thickness.
Higher values of LLT indicate a better lubrication of the ocular surface.
A thicker tear lipid layer helps reduce evaporation and is indicative of a more stable tear film.
The right eye only was used for this measure.
|
Day 14, after 2 hours of lens wear
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Les enquêteurs
- Directeur d'études: Clinical Manager, Pharmaceuticals, Global Medical Affairs, Alcon Research
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude
1 novembre 2014
Achèvement primaire (Réel)
1 juillet 2015
Achèvement de l'étude (Réel)
1 juillet 2015
Dates d'inscription aux études
Première soumission
14 novembre 2014
Première soumission répondant aux critères de contrôle qualité
17 novembre 2014
Première publication (Estimation)
18 novembre 2014
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
6 octobre 2016
Dernière mise à jour soumise répondant aux critères de contrôle qualité
4 octobre 2016
Dernière vérification
1 août 2016
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- LCO242-P001
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .