Speech Perception Performance With Gap-interleaved Stimulation Paradigms
Effect of Gap-interleaved Stimulation Paradigms in Speech Perception Performance of Experienced Cochlear Implant Recipients: a Single-centre, Randomised Controlled Single-blinded Study
調査の概要
詳細な説明
Auditory gaps can be induced in standard CI users by temporarily deactivating one to three electrodes. These gaps can be configured to have different gap durations.
The different variations of auditory stimulation with gaps will be presented to study participants via a standard MED-EL audio processor (Opus 2) bearing conformity marking. The programming of the processor will be performed using standard clinical hardware and software interfaces. These include the hardware interfaces "MAX interface box" and the "Diagnostic Interface Box" (DIB II) as well as the "MAESTRO" fitting software. After programming the respective configurations to the audio test-processor, a clinical word recognition test (Fournier) and a clinical consonant recognition test will be presented to the participants in a sound-shielded chamber using a free-field loudspeaker system.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Geneva、スイス、1205
- Geneva University Hospitals
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Informed Consent as documented by signature
- CI recipients using MED-EL implants (C40+, Pulsar, Sonata, Concerto, or Synchrony) and standard electrode arrays (Standard, FLEXSOFT, FLEX28, or FLEX24)
- >1 year post-implantation
- Regular CI use (at least 4 hours/day)
- At least 9 active electrodes in the device
- Good knowledge of French (at least B1 level according to the Common European Framework of Reference for Languages)
Exclusion Criteria:
- Patients with electro-acoustic stimulation (EAS) systems
- Unwillingness or inability to perform investigational tests
- Known or suspected drug or alcohol abuse
- Inability to follow the procedures of the study (e.g. due to language problems, psychological disorders, dementia, etc.)
- Previous enrolment into the current study
- Enrolment of the investigator, his/her family members, employees and other dependent persons
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Cochlear implant recipients
|
Investigation of the impact of time-fixed gaps (zero-stimulation periods) in the cochlear stimulation strategy on speech performance and hearing quality.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Performance in standardized speech perception tests
時間枠:Day 1
|
Consonant and word recognition tests
|
Day 1
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Comparison of volume levels resulting in equal loudness perception
時間枠:Day 1
|
Energetic efficiency of stimulation map
|
Day 1
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Quality of hearing
時間枠:Day 1
|
1-10 visual-analog scale
|
Day 1
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Angelica Perez Fornos, PhD、University Hospital, Geneva
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 2018-01938
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。