このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Assessment of Exercise Capacity in Virtual Reality

2020年11月2日 更新者:Sebastian Rutkowski、The Opole University of Technology

Evaluation of the Impact of Immersive Virtual Reality During the Submaximal Cardiorespiratory Fitness

The 20th century brought a dynamic development of new technologies, including virtual reality (VR). VR is an artificial image generated by IT technologies. It is most often associated with entertainment, but has a much wider application in other fields. The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer.

調査の概要

詳細な説明

Scientists suggests that there are four types of virtual reality: immersive virtual reality, desktop virtual reality (i.e., low-cost homebrew virtual reality), projection virtual reality, and simulation virtual reality. The sense of presence or immersion is a critical feature distinguishing virtual reality from other types of computer applications. It seems interesting whether immersion in virtual reality can influence the assessment of exercise capacity. The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer. It is assumed that an exercise capacity test on a cycloergometer will be performed in a traditional form and in a virtual reality.

研究の種類

介入

入学 (実際)

70

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Opole、ポーランド、45-758
        • Institute of Physiotherapy, Department of Physical Education and Physiotherapy, Opole University of Technology

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

20年~25年 (大人)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

説明

Inclusion Criteria:

1. Female and male, age: 20-25 years

Exclusion Criteria:

  1. diagnosed internal diseases
  2. diseases and injuries of the locomotors system impairing the function of transport 3 Cognitive disorders preventing contact with the patient, Mini-Mental State Examination < 24 points.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:Traditional exercise capacity test
Patients of the Ministry of the Interior and Administration hospital in Głuchołazy with a diagnosed disease unit of Chronic Obstructive Pulmonary Disease (COPD).
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm). Heart rate (HR) will be continuously recorded using a monitor Polar H10.
他の名前:
  • 心肺運動検査
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10. VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test. The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
他の名前:
  • Cardiopulmonary Exercise Testing in virtual reality
実験的:Immersive virtual reality exercise capacity test
Healthy volunteers, Students of Department of Physical Education and Physiotherapy, Opole University of Technology, Opole, Poland
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm). Heart rate (HR) will be continuously recorded using a monitor Polar H10.
他の名前:
  • 心肺運動検査
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10. VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test. The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
他の名前:
  • Cardiopulmonary Exercise Testing in virtual reality

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Exercise Testing- cycle ergometer
時間枠:First or second day of the assessment - the traditional exercise test
The exercise test on an electronically-braked cycle ergometer (Lode Excalibur Sport PFM) was used for evaluation. Test began with a unloaded cycling for 3 minutes, then 50W for 3 minutes followed by an incremental phase in which work rate increased by 25 watts every 3 minutes. Heart rate (HR) was continuously recorded. These submaximal tests were terminated when the subjects reached 85% of the age-predicted maximal HR (calculated as 220 - age)
First or second day of the assessment - the traditional exercise test
HRV
時間枠:First or second day of the assessment - the exercise test in VR
The Polar H10 monitor (Polar Electro Oy Inc., Kempele, Finland) was employed to record heart rate series at a sampling frequency of 1000 Hz. All HRV analyses were carried out with the Kubios HRV Premium version 3.3.1 (HRV analysis, University of Eastern Finland). The R-R interval series were filtered with the artifact correction algorithm which was set at the automatic mode. Time- and frequency-domain HRV parameters were analyzed.
First or second day of the assessment - the exercise test in VR

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Sebastian Rutkowski, PhD、The Opole University of Technology

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2019年12月17日

一次修了 (実際)

2020年6月27日

研究の完了 (実際)

2020年9月27日

試験登録日

最初に提出

2019年12月5日

QC基準を満たした最初の提出物

2019年12月10日

最初の投稿 (実際)

2019年12月12日

学習記録の更新

投稿された最後の更新 (実際)

2020年11月4日

QC基準を満たした最後の更新が送信されました

2020年11月2日

最終確認日

2020年11月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • OpoleUofTech1

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する