- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT04197024
Assessment of Exercise Capacity in Virtual Reality
2 novembre 2020 mis à jour par: Sebastian Rutkowski, The Opole University of Technology
Evaluation of the Impact of Immersive Virtual Reality During the Submaximal Cardiorespiratory Fitness
The 20th century brought a dynamic development of new technologies, including virtual reality (VR).
VR is an artificial image generated by IT technologies.
It is most often associated with entertainment, but has a much wider application in other fields.
The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer.
Aperçu de l'étude
Statut
Complété
Les conditions
Intervention / Traitement
Description détaillée
Scientists suggests that there are four types of virtual reality: immersive virtual reality, desktop virtual reality (i.e., low-cost homebrew virtual reality), projection virtual reality, and simulation virtual reality.
The sense of presence or immersion is a critical feature distinguishing virtual reality from other types of computer applications.
It seems interesting whether immersion in virtual reality can influence the assessment of exercise capacity.
The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer.
It is assumed that an exercise capacity test on a cycloergometer will be performed in a traditional form and in a virtual reality.
Type d'étude
Interventionnel
Inscription (Réel)
70
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
-
Opole, Pologne, 45-758
- Institute of Physiotherapy, Department of Physical Education and Physiotherapy, Opole University of Technology
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
20 ans à 25 ans (Adulte)
Accepte les volontaires sains
Oui
Sexes éligibles pour l'étude
Tout
La description
Inclusion Criteria:
1. Female and male, age: 20-25 years
Exclusion Criteria:
- diagnosed internal diseases
- diseases and injuries of the locomotors system impairing the function of transport 3 Cognitive disorders preventing contact with the patient, Mini-Mental State Examination < 24 points.
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Traditional exercise capacity test
Patients of the Ministry of the Interior and Administration hospital in Głuchołazy with a diagnosed disease unit of Chronic Obstructive Pulmonary Disease (COPD).
|
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W).
For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).
Heart rate (HR) will be continuously recorded using a monitor Polar H10.
Autres noms:
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W).
For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10.
VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test.
The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
Autres noms:
|
|
Expérimental: Immersive virtual reality exercise capacity test
Healthy volunteers, Students of Department of Physical Education and Physiotherapy, Opole University of Technology, Opole, Poland
|
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W).
For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).
Heart rate (HR) will be continuously recorded using a monitor Polar H10.
Autres noms:
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W).
For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10.
VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test.
The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Exercise Testing- cycle ergometer
Délai: First or second day of the assessment - the traditional exercise test
|
The exercise test on an electronically-braked cycle ergometer (Lode Excalibur Sport PFM) was used for evaluation.
Test began with a unloaded cycling for 3 minutes, then 50W for 3 minutes followed by an incremental phase in which work rate increased by 25 watts every 3 minutes.
Heart rate (HR) was continuously recorded.
These submaximal tests were terminated when the subjects reached 85% of the age-predicted maximal HR (calculated as 220 - age)
|
First or second day of the assessment - the traditional exercise test
|
|
HRV
Délai: First or second day of the assessment - the exercise test in VR
|
The Polar H10 monitor (Polar Electro Oy Inc., Kempele, Finland) was employed to record heart rate series at a sampling frequency of 1000 Hz.
All HRV analyses were carried out with the Kubios HRV Premium version 3.3.1 (HRV analysis, University of Eastern Finland).
The R-R interval series were filtered with the artifact correction algorithm which was set at the automatic mode.
Time- and frequency-domain HRV parameters were analyzed.
|
First or second day of the assessment - the exercise test in VR
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Les enquêteurs
- Chercheur principal: Sebastian Rutkowski, PhD, The Opole University of Technology
Publications et liens utiles
La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Réel)
17 décembre 2019
Achèvement primaire (Réel)
27 juin 2020
Achèvement de l'étude (Réel)
27 septembre 2020
Dates d'inscription aux études
Première soumission
5 décembre 2019
Première soumission répondant aux critères de contrôle qualité
10 décembre 2019
Première publication (Réel)
12 décembre 2019
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
4 novembre 2020
Dernière mise à jour soumise répondant aux critères de contrôle qualité
2 novembre 2020
Dernière vérification
1 novembre 2020
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- OpoleUofTech1
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
NON
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Non
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .