Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Assessment of Exercise Capacity in Virtual Reality

2 de noviembre de 2020 actualizado por: Sebastian Rutkowski, The Opole University of Technology

Evaluation of the Impact of Immersive Virtual Reality During the Submaximal Cardiorespiratory Fitness

The 20th century brought a dynamic development of new technologies, including virtual reality (VR). VR is an artificial image generated by IT technologies. It is most often associated with entertainment, but has a much wider application in other fields. The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer.

Descripción general del estudio

Descripción detallada

Scientists suggests that there are four types of virtual reality: immersive virtual reality, desktop virtual reality (i.e., low-cost homebrew virtual reality), projection virtual reality, and simulation virtual reality. The sense of presence or immersion is a critical feature distinguishing virtual reality from other types of computer applications. It seems interesting whether immersion in virtual reality can influence the assessment of exercise capacity. The aim of the study is to assess the influence of the application of immersive virtual reality during an exercise capacity test on a bicycle ergometer. It is assumed that an exercise capacity test on a cycloergometer will be performed in a traditional form and in a virtual reality.

Tipo de estudio

Intervencionista

Inscripción (Actual)

70

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Opole, Polonia, 45-758
        • Institute of Physiotherapy, Department of Physical Education and Physiotherapy, Opole University of Technology

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

20 años a 25 años (Adulto)

Acepta Voluntarios Saludables

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

1. Female and male, age: 20-25 years

Exclusion Criteria:

  1. diagnosed internal diseases
  2. diseases and injuries of the locomotors system impairing the function of transport 3 Cognitive disorders preventing contact with the patient, Mini-Mental State Examination < 24 points.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Diagnóstico
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Traditional exercise capacity test
Patients of the Ministry of the Interior and Administration hospital in Głuchołazy with a diagnosed disease unit of Chronic Obstructive Pulmonary Disease (COPD).
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm). Heart rate (HR) will be continuously recorded using a monitor Polar H10.
Otros nombres:
  • Prueba de ejercicio cardiopulmonar
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10. VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test. The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
Otros nombres:
  • Cardiopulmonary Exercise Testing in virtual reality
Experimental: Immersive virtual reality exercise capacity test
Healthy volunteers, Students of Department of Physical Education and Physiotherapy, Opole University of Technology, Opole, Poland
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm). Heart rate (HR) will be continuously recorded using a monitor Polar H10.
Otros nombres:
  • Prueba de ejercicio cardiopulmonar
Patients will be assessed by symptom-limited maximal cardiopulmonary exercise testing (CPET) following a 25W, tree-minute stage, beginning at 25W (healthy volunteers will start the test with a load of 50W). For both sexes and arms, participants will be instructed during the test to remain at the frequency between 60 to 80 rotations per minute (rpm).Heart rate (HR) will be continuously recorded using a monitor Polar H10. VR HTC Vive Pro goggles along with VR health care (aerobic exercise) VR Cycling software will be used for stimulation throughout the duration of the test. The HTC Vive Tracker device will be also use to link images in virtual reality with the pedal speed.
Otros nombres:
  • Cardiopulmonary Exercise Testing in virtual reality

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Exercise Testing- cycle ergometer
Periodo de tiempo: First or second day of the assessment - the traditional exercise test
The exercise test on an electronically-braked cycle ergometer (Lode Excalibur Sport PFM) was used for evaluation. Test began with a unloaded cycling for 3 minutes, then 50W for 3 minutes followed by an incremental phase in which work rate increased by 25 watts every 3 minutes. Heart rate (HR) was continuously recorded. These submaximal tests were terminated when the subjects reached 85% of the age-predicted maximal HR (calculated as 220 - age)
First or second day of the assessment - the traditional exercise test
HRV
Periodo de tiempo: First or second day of the assessment - the exercise test in VR
The Polar H10 monitor (Polar Electro Oy Inc., Kempele, Finland) was employed to record heart rate series at a sampling frequency of 1000 Hz. All HRV analyses were carried out with the Kubios HRV Premium version 3.3.1 (HRV analysis, University of Eastern Finland). The R-R interval series were filtered with the artifact correction algorithm which was set at the automatic mode. Time- and frequency-domain HRV parameters were analyzed.
First or second day of the assessment - the exercise test in VR

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Sebastian Rutkowski, PhD, The Opole University of Technology

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

17 de diciembre de 2019

Finalización primaria (Actual)

27 de junio de 2020

Finalización del estudio (Actual)

27 de septiembre de 2020

Fechas de registro del estudio

Enviado por primera vez

5 de diciembre de 2019

Primero enviado que cumplió con los criterios de control de calidad

10 de diciembre de 2019

Publicado por primera vez (Actual)

12 de diciembre de 2019

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

4 de noviembre de 2020

Última actualización enviada que cumplió con los criterios de control de calidad

2 de noviembre de 2020

Última verificación

1 de noviembre de 2020

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • OpoleUofTech1

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Ensayos clínicos sobre Exercise capacity test

3
Suscribir