Scan-rescan Reproducibility of Myelin Sensitive MRI Techniques
調査の概要
詳細な説明
Magnetization Transfer Imaging (MTI) permits the assessment of the integrity of macromolecules in brain tissue, such as myelin and cellular/axonal membrane components.
Multi-echo Susceptibility-Based imaging (SBI) provides quantitative susceptibility maps and T2* maps that - when combined - permit the disentanglement of myelin from iron and various phases of myelin degradation.
Myelin Water Imaging (MWI) quantifies the water trapped between myelin layers by separating the multiple water components in T2 relaxometry data. In fact, the presence of myelin on water pools bound to it provokes a loss in magnetic resonance (MR)-signal coherence, which is more rapid than the one characterizing the water pools located within the axons or in the cytoplasm.
A method based on a spiral acquisition that achieves a myelin-specific signal in clinically compatible scan times is currently applied: T1 relaxometry (quantitative T1, qT1) - which measures the time that a perturbed nuclear spin distribution needs to get back to equilibrium in the longitudinal plane- is sensitive to a number of components of the brain tissue such as myelin, axonal diameter and the overall architectural organization of the brain tissue.
Finally, multi-shell diffusion allows the application of mathematical models of diffusion compartments, which in part are influenced by myelin integrity.
The goal of this study is to assess the stability of these techniques in scan-rescan experiment on 20 healthy subjects.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Basel、スイス、4031
- Neurologische Klinik und Poliklinik, University Hospital Basel
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- No neurological or psychiatric disorder
Exclusion Criteria:
- Pregnancy
- Contraindication to MRI (eg, claustrophobia, metallic implants, pacemaker etc).
- Inability to give consent.
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
analysis of variance between MTI, SBI, MWI, T1 relaxometry and multi-shell diffusion obtained in each subject in each of the 3 scan sessions
時間枠:1 hour total scan time (during a time period of max. 1 week)
|
statistical analysis of variance between MTI, SBI, MWI, T1 relaxometry and multi-shell diffusion obtained in each subject in each of the 3 scan sessions
|
1 hour total scan time (during a time period of max. 1 week)
|
協力者と研究者
捜査官
- 主任研究者:Cristina Granziera, Prof. Dr. med.、Neurologische Klinik und Poliklinik, University Hospital Basel
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- 2020-02826; me20Granziera3
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。