Scan-rescan Reproducibility of Myelin Sensitive MRI Techniques
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Magnetization Transfer Imaging (MTI) permits the assessment of the integrity of macromolecules in brain tissue, such as myelin and cellular/axonal membrane components.
Multi-echo Susceptibility-Based imaging (SBI) provides quantitative susceptibility maps and T2* maps that - when combined - permit the disentanglement of myelin from iron and various phases of myelin degradation.
Myelin Water Imaging (MWI) quantifies the water trapped between myelin layers by separating the multiple water components in T2 relaxometry data. In fact, the presence of myelin on water pools bound to it provokes a loss in magnetic resonance (MR)-signal coherence, which is more rapid than the one characterizing the water pools located within the axons or in the cytoplasm.
A method based on a spiral acquisition that achieves a myelin-specific signal in clinically compatible scan times is currently applied: T1 relaxometry (quantitative T1, qT1) - which measures the time that a perturbed nuclear spin distribution needs to get back to equilibrium in the longitudinal plane- is sensitive to a number of components of the brain tissue such as myelin, axonal diameter and the overall architectural organization of the brain tissue.
Finally, multi-shell diffusion allows the application of mathematical models of diffusion compartments, which in part are influenced by myelin integrity.
The goal of this study is to assess the stability of these techniques in scan-rescan experiment on 20 healthy subjects.
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Basel, Szwajcaria, 4031
- Neurologische Klinik und Poliklinik, University Hospital Basel
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- No neurological or psychiatric disorder
Exclusion Criteria:
- Pregnancy
- Contraindication to MRI (eg, claustrophobia, metallic implants, pacemaker etc).
- Inability to give consent.
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
analysis of variance between MTI, SBI, MWI, T1 relaxometry and multi-shell diffusion obtained in each subject in each of the 3 scan sessions
Ramy czasowe: 1 hour total scan time (during a time period of max. 1 week)
|
statistical analysis of variance between MTI, SBI, MWI, T1 relaxometry and multi-shell diffusion obtained in each subject in each of the 3 scan sessions
|
1 hour total scan time (during a time period of max. 1 week)
|
Współpracownicy i badacze
Współpracownicy
Śledczy
- Główny śledczy: Cristina Granziera, Prof. Dr. med., Neurologische Klinik und Poliklinik, University Hospital Basel
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 2020-02826; me20Granziera3
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .