Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing ACL Rupture
2021年7月7日 更新者:Peking University Third Hospital
Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing Anterior Cruciate Ligament Rupture
We introduced an automatic knee arthrometer (AKA) and aimed to evaluate the repeatability and effectiveness thereof in diagnosing ACL rupture compared with the KT-2000.
調査の概要
状態
完了
詳細な説明
The AKA was compared to the KT-2000 at 134 N in this study, the anterior displacement and difference of both knees of every subject were measured.
The first protocol was designed to evaluate examiner effect (level of experience) and contralateral-side effect (left or right knee) in a single healthy subject, ten times, on ten consecutive days.
The second was to compare the stability in 20 healthy subjects, with a single experienced examiner.
Third, we recruited 200 ACL rupture and 200 healthy subjects as contrast to compare the accuracy of the devices in diagnosing ACL rupture.
研究の種類
観察的
入学 (実際)
421
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究場所
-
-
Beijing
-
Beijing、Beijing、中国、100191
- Peking University Third Hospital
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
18年~45年 (大人)
健康ボランティアの受け入れ
はい
受講資格のある性別
全て
サンプリング方法
非確率サンプル
調査対象母集団
one healthy subject was tested with both devices for ten consecutive days to estimate examiner effect; 20 healthy subjects were tested with both devices to determine the method effect; 200 medicine students volunteered as healthy subjects; each with pain-free knees in the last three months, and without a history of knee injury; 200 patients with ACL rupture from our institution were also included.
説明
Inclusion Criteria:
- patients with ACL rupture from our institution were included. All patients were diagnosed by sports medicine specialists based on clinical manifestation, combined with imaging examinations, and hospitalized for further surgery.
Exclusion Criteria:
- Patients aged <18 or >45 years, with combined multiple knee ligament injury combinations, and/or limited range of motion of the knee (unable to flex to 20-30°)
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Examiner effect group
Two examiners performed the test on one healthy subject with both devices for ten consecutive days.
We measured the AD of both knees and calculated the ADD of every test.
We evaluated the contralateral-side effect by comparing the AD standard deviations of each knee with both devices, and compared the average ADD tested by different examiners with the same device, to estimate examiner effect.
|
The experienced examiner performed tests on 20 healthy subjects
|
|
Method effect group
The experienced examiner performed tests on 20 healthy subjects using both devices.
The means and standard deviations of both knees were calculated.
We examined the difference in measurements using each device to determine the method effect.
|
Two examiners performed the test on one healthy subject with both devices for ten consecutive days.
|
|
Equipment effectiveness group
The experienced examiner performed tests on 200 ACL ruptureand 200 healthy subjects using each device.
Effectiveness was analyzed using 1.5 mm and 3 mm threshold values in ACL tears.
|
200 ACL rupture and 200 healthy subjects were recruited as contrast to compare the accuracy of the devices in diagnosing ACL rupture.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Side-to-side difference (SSD)
時間枠:within 3 months after ACL rupture
|
Side-to-side difference (SSD)at 134 N
|
within 3 months after ACL rupture
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
捜査官
- スタディチェア:yingfang ao, M.D.、Peking University Third Hospital
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始 (実際)
2020年6月30日
一次修了 (実際)
2020年7月1日
研究の完了 (実際)
2020年12月31日
試験登録日
最初に提出
2021年6月27日
QC基準を満たした最初の提出物
2021年7月7日
最初の投稿 (実際)
2021年7月9日
学習記録の更新
投稿された最後の更新 (実際)
2021年7月9日
QC基準を満たした最後の更新が送信されました
2021年7月7日
最終確認日
2021年7月1日