Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing ACL Rupture

7 luglio 2021 aggiornato da: Peking University Third Hospital

Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing Anterior Cruciate Ligament Rupture

We introduced an automatic knee arthrometer (AKA) and aimed to evaluate the repeatability and effectiveness thereof in diagnosing ACL rupture compared with the KT-2000.

Panoramica dello studio

Descrizione dettagliata

The AKA was compared to the KT-2000 at 134 N in this study, the anterior displacement and difference of both knees of every subject were measured. The first protocol was designed to evaluate examiner effect (level of experience) and contralateral-side effect (left or right knee) in a single healthy subject, ten times, on ten consecutive days. The second was to compare the stability in 20 healthy subjects, with a single experienced examiner. Third, we recruited 200 ACL rupture and 200 healthy subjects as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Tipo di studio

Osservativo

Iscrizione (Effettivo)

421

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Beijing
      • Beijing, Beijing, Cina, 100191
        • Peking University Third Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 45 anni (Adulto)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Tutto

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

one healthy subject was tested with both devices for ten consecutive days to estimate examiner effect; 20 healthy subjects were tested with both devices to determine the method effect; 200 medicine students volunteered as healthy subjects; each with pain-free knees in the last three months, and without a history of knee injury; 200 patients with ACL rupture from our institution were also included.

Descrizione

Inclusion Criteria:

  • patients with ACL rupture from our institution were included. All patients were diagnosed by sports medicine specialists based on clinical manifestation, combined with imaging examinations, and hospitalized for further surgery.

Exclusion Criteria:

  • Patients aged <18 or >45 years, with combined multiple knee ligament injury combinations, and/or limited range of motion of the knee (unable to flex to 20-30°)

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Examiner effect group
Two examiners performed the test on one healthy subject with both devices for ten consecutive days. We measured the AD of both knees and calculated the ADD of every test. We evaluated the contralateral-side effect by comparing the AD standard deviations of each knee with both devices, and compared the average ADD tested by different examiners with the same device, to estimate examiner effect.
The experienced examiner performed tests on 20 healthy subjects
Method effect group
The experienced examiner performed tests on 20 healthy subjects using both devices. The means and standard deviations of both knees were calculated. We examined the difference in measurements using each device to determine the method effect.
Two examiners performed the test on one healthy subject with both devices for ten consecutive days.
Equipment effectiveness group
The experienced examiner performed tests on 200 ACL ruptureand 200 healthy subjects using each device. Effectiveness was analyzed using 1.5 mm and 3 mm threshold values in ACL tears.
200 ACL rupture and 200 healthy subjects were recruited as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Side-to-side difference (SSD)
Lasso di tempo: within 3 months after ACL rupture
Side-to-side difference (SSD)at 134 N
within 3 months after ACL rupture

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Collaboratori

Investigatori

  • Cattedra di studio: yingfang ao, M.D., Peking University Third Hospital

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

30 giugno 2020

Completamento primario (Effettivo)

1 luglio 2020

Completamento dello studio (Effettivo)

31 dicembre 2020

Date di iscrizione allo studio

Primo inviato

27 giugno 2021

Primo inviato che soddisfa i criteri di controllo qualità

7 luglio 2021

Primo Inserito (Effettivo)

9 luglio 2021

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

9 luglio 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

7 luglio 2021

Ultimo verificato

1 luglio 2021

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • M2020263

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

INDECISO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi