Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing ACL Rupture

7. juli 2021 oppdatert av: Peking University Third Hospital

Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing Anterior Cruciate Ligament Rupture

We introduced an automatic knee arthrometer (AKA) and aimed to evaluate the repeatability and effectiveness thereof in diagnosing ACL rupture compared with the KT-2000.

Studieoversikt

Detaljert beskrivelse

The AKA was compared to the KT-2000 at 134 N in this study, the anterior displacement and difference of both knees of every subject were measured. The first protocol was designed to evaluate examiner effect (level of experience) and contralateral-side effect (left or right knee) in a single healthy subject, ten times, on ten consecutive days. The second was to compare the stability in 20 healthy subjects, with a single experienced examiner. Third, we recruited 200 ACL rupture and 200 healthy subjects as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Studietype

Observasjonsmessig

Registrering (Faktiske)

421

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Beijing
      • Beijing, Beijing, Kina, 100191
        • Peking University Third Hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år til 45 år (Voksen)

Tar imot friske frivillige

Ja

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

one healthy subject was tested with both devices for ten consecutive days to estimate examiner effect; 20 healthy subjects were tested with both devices to determine the method effect; 200 medicine students volunteered as healthy subjects; each with pain-free knees in the last three months, and without a history of knee injury; 200 patients with ACL rupture from our institution were also included.

Beskrivelse

Inclusion Criteria:

  • patients with ACL rupture from our institution were included. All patients were diagnosed by sports medicine specialists based on clinical manifestation, combined with imaging examinations, and hospitalized for further surgery.

Exclusion Criteria:

  • Patients aged <18 or >45 years, with combined multiple knee ligament injury combinations, and/or limited range of motion of the knee (unable to flex to 20-30°)

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
Examiner effect group
Two examiners performed the test on one healthy subject with both devices for ten consecutive days. We measured the AD of both knees and calculated the ADD of every test. We evaluated the contralateral-side effect by comparing the AD standard deviations of each knee with both devices, and compared the average ADD tested by different examiners with the same device, to estimate examiner effect.
The experienced examiner performed tests on 20 healthy subjects
Method effect group
The experienced examiner performed tests on 20 healthy subjects using both devices. The means and standard deviations of both knees were calculated. We examined the difference in measurements using each device to determine the method effect.
Two examiners performed the test on one healthy subject with both devices for ten consecutive days.
Equipment effectiveness group
The experienced examiner performed tests on 200 ACL ruptureand 200 healthy subjects using each device. Effectiveness was analyzed using 1.5 mm and 3 mm threshold values in ACL tears.
200 ACL rupture and 200 healthy subjects were recruited as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Side-to-side difference (SSD)
Tidsramme: within 3 months after ACL rupture
Side-to-side difference (SSD)at 134 N
within 3 months after ACL rupture

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Samarbeidspartnere

Etterforskere

  • Studiestol: yingfang ao, M.D., Peking University Third Hospital

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

30. juni 2020

Primær fullføring (Faktiske)

1. juli 2020

Studiet fullført (Faktiske)

31. desember 2020

Datoer for studieregistrering

Først innsendt

27. juni 2021

Først innsendt som oppfylte QC-kriteriene

7. juli 2021

Først lagt ut (Faktiske)

9. juli 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

9. juli 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

7. juli 2021

Sist bekreftet

1. juli 2021

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • M2020263

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

UBESLUTTE

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere