Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing ACL Rupture

7 июля 2021 г. обновлено: Peking University Third Hospital

Accuracy and Stability of a New Automatic Knee Arthrometer in Diagnosing Anterior Cruciate Ligament Rupture

We introduced an automatic knee arthrometer (AKA) and aimed to evaluate the repeatability and effectiveness thereof in diagnosing ACL rupture compared with the KT-2000.

Обзор исследования

Подробное описание

The AKA was compared to the KT-2000 at 134 N in this study, the anterior displacement and difference of both knees of every subject were measured. The first protocol was designed to evaluate examiner effect (level of experience) and contralateral-side effect (left or right knee) in a single healthy subject, ten times, on ten consecutive days. The second was to compare the stability in 20 healthy subjects, with a single experienced examiner. Third, we recruited 200 ACL rupture and 200 healthy subjects as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Тип исследования

Наблюдательный

Регистрация (Действительный)

421

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Beijing
      • Beijing, Beijing, Китай, 100191
        • Peking University Third Hospital

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 18 лет до 45 лет (Взрослый)

Принимает здоровых добровольцев

Да

Полы, имеющие право на обучение

Все

Метод выборки

Невероятностная выборка

Исследуемая популяция

one healthy subject was tested with both devices for ten consecutive days to estimate examiner effect; 20 healthy subjects were tested with both devices to determine the method effect; 200 medicine students volunteered as healthy subjects; each with pain-free knees in the last three months, and without a history of knee injury; 200 patients with ACL rupture from our institution were also included.

Описание

Inclusion Criteria:

  • patients with ACL rupture from our institution were included. All patients were diagnosed by sports medicine specialists based on clinical manifestation, combined with imaging examinations, and hospitalized for further surgery.

Exclusion Criteria:

  • Patients aged <18 or >45 years, with combined multiple knee ligament injury combinations, and/or limited range of motion of the knee (unable to flex to 20-30°)

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
Examiner effect group
Two examiners performed the test on one healthy subject with both devices for ten consecutive days. We measured the AD of both knees and calculated the ADD of every test. We evaluated the contralateral-side effect by comparing the AD standard deviations of each knee with both devices, and compared the average ADD tested by different examiners with the same device, to estimate examiner effect.
The experienced examiner performed tests on 20 healthy subjects
Method effect group
The experienced examiner performed tests on 20 healthy subjects using both devices. The means and standard deviations of both knees were calculated. We examined the difference in measurements using each device to determine the method effect.
Two examiners performed the test on one healthy subject with both devices for ten consecutive days.
Equipment effectiveness group
The experienced examiner performed tests on 200 ACL ruptureand 200 healthy subjects using each device. Effectiveness was analyzed using 1.5 mm and 3 mm threshold values in ACL tears.
200 ACL rupture and 200 healthy subjects were recruited as contrast to compare the accuracy of the devices in diagnosing ACL rupture.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Side-to-side difference (SSD)
Временное ограничение: within 3 months after ACL rupture
Side-to-side difference (SSD)at 134 N
within 3 months after ACL rupture

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Соавторы

Следователи

  • Учебный стул: yingfang ao, M.D., Peking University Third Hospital

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

30 июня 2020 г.

Первичное завершение (Действительный)

1 июля 2020 г.

Завершение исследования (Действительный)

31 декабря 2020 г.

Даты регистрации исследования

Первый отправленный

27 июня 2021 г.

Впервые представлено, что соответствует критериям контроля качества

7 июля 2021 г.

Первый опубликованный (Действительный)

9 июля 2021 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

9 июля 2021 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

7 июля 2021 г.

Последняя проверка

1 июля 2021 г.

Дополнительная информация

Термины, связанные с этим исследованием

Дополнительные соответствующие термины MeSH

Другие идентификационные номера исследования

  • M2020263

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться