Evaluation of Ocular Biometry in PACD With Two Swept Source Optical Coherence Tomography Devices
Evaluation of Ocular Biometry in Primary Angle-closure Disease With Two Swept Source Optical Coherence Tomography Devices
Purpose: To investigate agreement between 2 swept source OCT biometers, IOL M.aster700 and Anterion, in various ocular biometry and intraocular lens (IOL) calculations of primary angle-closure disease (PACD).
Methods: This was a prospective study conducted in a tertiary eye care centre involving biometric measurements obtained with 2 devices in phakic eye with diagnosis of PACD. Mean difference and intraclass correlation coefficient (ICC) with confidence limits were assessed, and calculations of estimated residual refraction of the IOL were analysed using Barrett's formula.
調査の概要
詳細な説明
Primary angle-closure disease (PACD) is the leading cause of blindness worldwide. PACD is an anatomic disorder, typically of relatively small eye with shallow anterior chamber depth (ACD), thick lens, shorter axial length (AL), small corneal curvature, and relatively anterior lens position. Pupillary block, plateau iris and phacomorphic mechanisms play major roles in the pathophysiology of the disease, and pupillary block is thought to be the most common causal mechanism.
For decades, phacoemulsification and intraocular lens implantation (PEI) has been proposed for initial management of PACD.4 PEI relieves pupillary block, deepening ACD and widening irido-corneal angle.
Biometry is essential in evaluating ocular dimensions and calculating IOL power in PACD, and ocular biometers have been evolving in recent years. Optical coherence tomography (OCT) includes partial coherence interferometry (PCI), and swept source OCT (SS-OCT) is in general use in clinical practice. The agreement of the calculations of these devices has been studied by many investigators; however, research into their agreement in PACD patients has been sparse so far. A newer SS-OCT, Anterion, is now available and its performance needs to be evaluated.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Bangkok、タイ、10400
- Somporn Chantra
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Inclusion criteria were age > 40 years old
- phakic eye
- diagnosis of PACD, including primary angle-closure suspect (PACS), primary angle-closure (PAC) and primary angle-closure glaucoma (PACG) as classified by Foster et al
Exclusion Criteria:
- patients who had opaque optical media
- dense cataract
- anterior and/or posterior segment diseases such as advanced pterygium, diabetic retinopathy, or maculopathy
- Participants who had previous history of ocular trauma, ocular surgery
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
one group compared two measurement methods
|
2 swept source OCT biometers, IOL Master700 and Anterion
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intraclass correlation coefficient of IOL power calculation
時間枠:30 minutes per person
|
agreement between 2 swept source OCT biometers, IOL Master700 and Anterion, in intraocular lens (IOL) calculations
|
30 minutes per person
|
|
Intraclass correlation coefficient of various ocular biometry
時間枠:30 minutes per person
|
agreement between 2 swept source OCT biometers, IOL Master700 and Anterion, in various ocular biometry( ACD, AL, LT, K1, K2, WTW)
|
30 minutes per person
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Somporn Chantra, MD、Rajavithi Hospital
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- Rajavithi Hospital (その他の助成金/資金番号:Rajavithi Hospital)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。