このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Anterior Chamber Angle Examination in Angle Closure Suspect Patients

2022年1月25日 更新者:Mohamed Salah、Minia University
The aim of this study is to detect PACG suspects using both AS OCT and Scheimpflug imaging.

調査の概要

詳細な説明

Glaucoma is a form of progressive optic neuropathy and is one of the leading causes of preventable blindness worldwide. The average life span is increasing leading to more individuals developing glaucoma as well as having the disease longer, which makes early detection and management very important.[1] Glaucoma is characterized by loss of retinal ganglion cells (RGCs) recognized as optic nerve head (ONH) changes, corresponding visual field (VF) defects and retinal nerve fiber layer (RNFL) loss. At least 40% of RGCs are lost before the VFs show a defect, hence the emphasis on early diagnosis in the stage of glaucoma suspect.[2] There are two types of glaucoma suspect: Primary Open angle and primary angle closure suspect.(3) Primary angle-closure (PAC) suspects can be detected by the following: the trabecular meshwork can only be seen in 180º or less of anterior chamber angle (AC) by gonioscopy, the intraocular pressure(IOP) remains within normal limits and no structural damage to the optic nerve is present.[4] Time domain Optical coherence tomography (TD-OCT) was initially designed to image the posterior segment and retina, but its capability to generate cross-sectional images of internal biological structures without contacting the ocular surface was quickly adapted to visualize the anterior segment and cornea.[5].

Spectral domain anterior segment OCT (SD-OCT) technology allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Spectral-domain OCT(SD OCT) instruments working at 840 nm can reliably identify fine angle structures such as Schwalbe's line.(6) Scheimpflug imaging also offers non-contact imaging of the anterior segment. Although Scheimpflug photography cannot fully visualize the entire angle, the software available on the Pentacam system (Oculus Optikgeräte, Wetzlar, Germany) provides extrapolated measurements of the anterior chamber volume (ACV), which have shown promise in screening for narrow angles.(7)

研究の種類

観察的

入学 (実際)

40

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Minya、エジプト
        • Minia University Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

40年~70年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

Residents of Minia Governorate diagnosed with SLE with renal affection and without renal affection.

説明

Inclusion Criteria:

  • Hyperopes. 2-Shallow AC. 3-With gonioscopy carried out under dim-light conditions without indentation ,with the eye in primary position there is inability to visualize ≤ 180° of the posterior trabecular meshwork (TM) in the absence of peripheral anterior 4-IOP ≤ 21 as measured by tonometry. 5-Normal visual field on static automated perimetry (SAP) testing. 5-Normal optic nerve head (ONH) appearance on fundus biomicroscopy. 6-Family history of primary angle closure disease.

Exclusion Criteria:

  • 1-Eyes with significant corneal opacity that can impare signal strings of any of the used imaging modalities.

    2-Eyes wih history of intraocular surgery (e.g. cataract surgery ,retinal detachment surgery).

    3-Eyes with history of laser procedures (e.g.laser peripheral iridotomy). 4-Eyes with anterior segment pathology as iridocyclitis or angle disgenesis 5. Eyes with history of trauma. 6- Eyes with findings suggestive of 2dry cause of glaucoma (e.g. iris or angle neovascularization, any iris or corneal abnormalities, dilated episcleral vessels ).

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 観測モデル:コホート
  • 時間の展望:回顧

コホートと介入

グループ/コホート
介入・治療
40 pateint glucoma suspect
ASOCT
Anterior segment imaging using RTVue XR 100 Avanti OCT platform (Optovue Inc.,Fairmont, CA).
Anterior segment imaging using Oculus Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany).

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Anterior segment parameters as measured by AS-OCT:
時間枠:3 months
Anterior chamber depth (ACD)..
3 months
Anterior segment parameters as measured by Oculus Pentacam:
時間枠:3 months
Anterior chamber angle (ACA).
3 months
Anterior segment parameters by ASOCT
時間枠:3 months
Angle opening distance at 750 µm (AOD750).
3 months
Anterior segment parameters by OCT
時間枠:3 months
Anterior chamber angle (ACA).
3 months
Pentacam parameters
時間枠:3 months
Anterior chamber volume (ACV).
3 months
Pentacam parameters by Oculus Pentacam:
時間枠:3 months
Anterior chamber depth (ACD).
3 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Mohamed Salah、Minia University Hospital

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2019年4月1日

一次修了 (実際)

2019年12月1日

研究の完了 (実際)

2020年1月1日

試験登録日

最初に提出

2022年1月7日

QC基準を満たした最初の提出物

2022年1月25日

最初の投稿 (実際)

2022年1月26日

学習記録の更新

投稿された最後の更新 (実際)

2022年1月26日

QC基準を満たした最後の更新が送信されました

2022年1月25日

最終確認日

2022年1月1日

詳しくは

本研究に関する用語

キーワード

追加の関連 MeSH 用語

その他の研究ID番号

  • AC angle angle closure suspect

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する