- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT05209204
Anterior Chamber Angle Examination in Angle Closure Suspect Patients
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Glaucoma is a form of progressive optic neuropathy and is one of the leading causes of preventable blindness worldwide. The average life span is increasing leading to more individuals developing glaucoma as well as having the disease longer, which makes early detection and management very important.[1] Glaucoma is characterized by loss of retinal ganglion cells (RGCs) recognized as optic nerve head (ONH) changes, corresponding visual field (VF) defects and retinal nerve fiber layer (RNFL) loss. At least 40% of RGCs are lost before the VFs show a defect, hence the emphasis on early diagnosis in the stage of glaucoma suspect.[2] There are two types of glaucoma suspect: Primary Open angle and primary angle closure suspect.(3) Primary angle-closure (PAC) suspects can be detected by the following: the trabecular meshwork can only be seen in 180º or less of anterior chamber angle (AC) by gonioscopy, the intraocular pressure(IOP) remains within normal limits and no structural damage to the optic nerve is present.[4] Time domain Optical coherence tomography (TD-OCT) was initially designed to image the posterior segment and retina, but its capability to generate cross-sectional images of internal biological structures without contacting the ocular surface was quickly adapted to visualize the anterior segment and cornea.[5].
Spectral domain anterior segment OCT (SD-OCT) technology allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Spectral-domain OCT(SD OCT) instruments working at 840 nm can reliably identify fine angle structures such as Schwalbe's line.(6) Scheimpflug imaging also offers non-contact imaging of the anterior segment. Although Scheimpflug photography cannot fully visualize the entire angle, the software available on the Pentacam system (Oculus Optikgeräte, Wetzlar, Germany) provides extrapolated measurements of the anterior chamber volume (ACV), which have shown promise in screening for narrow angles.(7)
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Minya, Egipt
- Minia University Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Hyperopes. 2-Shallow AC. 3-With gonioscopy carried out under dim-light conditions without indentation ,with the eye in primary position there is inability to visualize ≤ 180° of the posterior trabecular meshwork (TM) in the absence of peripheral anterior 4-IOP ≤ 21 as measured by tonometry. 5-Normal visual field on static automated perimetry (SAP) testing. 5-Normal optic nerve head (ONH) appearance on fundus biomicroscopy. 6-Family history of primary angle closure disease.
Exclusion Criteria:
1-Eyes with significant corneal opacity that can impare signal strings of any of the used imaging modalities.
2-Eyes wih history of intraocular surgery (e.g. cataract surgery ,retinal detachment surgery).
3-Eyes with history of laser procedures (e.g.laser peripheral iridotomy). 4-Eyes with anterior segment pathology as iridocyclitis or angle disgenesis 5. Eyes with history of trauma. 6- Eyes with findings suggestive of 2dry cause of glaucoma (e.g. iris or angle neovascularization, any iris or corneal abnormalities, dilated episcleral vessels ).
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Modele obserwacyjne: Kohorta
- Perspektywy czasowe: Z mocą wsteczną
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
40 pateint glucoma suspect
ASOCT
|
Anterior segment imaging using RTVue XR 100 Avanti OCT platform (Optovue Inc.,Fairmont, CA).
Anterior segment imaging using Oculus Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany).
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Anterior segment parameters as measured by AS-OCT:
Ramy czasowe: 3 months
|
Anterior chamber depth (ACD)..
|
3 months
|
|
Anterior segment parameters as measured by Oculus Pentacam:
Ramy czasowe: 3 months
|
Anterior chamber angle (ACA).
|
3 months
|
|
Anterior segment parameters by ASOCT
Ramy czasowe: 3 months
|
Angle opening distance at 750 µm (AOD750).
|
3 months
|
|
Anterior segment parameters by OCT
Ramy czasowe: 3 months
|
Anterior chamber angle (ACA).
|
3 months
|
|
Pentacam parameters
Ramy czasowe: 3 months
|
Anterior chamber volume (ACV).
|
3 months
|
|
Pentacam parameters by Oculus Pentacam:
Ramy czasowe: 3 months
|
Anterior chamber depth (ACD).
|
3 months
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Mohamed Salah, Minia University Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- AC angle angle closure suspect
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .