- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05209204
Anterior Chamber Angle Examination in Angle Closure Suspect Patients
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Glaucoma is a form of progressive optic neuropathy and is one of the leading causes of preventable blindness worldwide. The average life span is increasing leading to more individuals developing glaucoma as well as having the disease longer, which makes early detection and management very important.[1] Glaucoma is characterized by loss of retinal ganglion cells (RGCs) recognized as optic nerve head (ONH) changes, corresponding visual field (VF) defects and retinal nerve fiber layer (RNFL) loss. At least 40% of RGCs are lost before the VFs show a defect, hence the emphasis on early diagnosis in the stage of glaucoma suspect.[2] There are two types of glaucoma suspect: Primary Open angle and primary angle closure suspect.(3) Primary angle-closure (PAC) suspects can be detected by the following: the trabecular meshwork can only be seen in 180º or less of anterior chamber angle (AC) by gonioscopy, the intraocular pressure(IOP) remains within normal limits and no structural damage to the optic nerve is present.[4] Time domain Optical coherence tomography (TD-OCT) was initially designed to image the posterior segment and retina, but its capability to generate cross-sectional images of internal biological structures without contacting the ocular surface was quickly adapted to visualize the anterior segment and cornea.[5].
Spectral domain anterior segment OCT (SD-OCT) technology allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Spectral-domain OCT(SD OCT) instruments working at 840 nm can reliably identify fine angle structures such as Schwalbe's line.(6) Scheimpflug imaging also offers non-contact imaging of the anterior segment. Although Scheimpflug photography cannot fully visualize the entire angle, the software available on the Pentacam system (Oculus Optikgeräte, Wetzlar, Germany) provides extrapolated measurements of the anterior chamber volume (ACV), which have shown promise in screening for narrow angles.(7)
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
-
Minya, Egito
- Minia University Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Hyperopes. 2-Shallow AC. 3-With gonioscopy carried out under dim-light conditions without indentation ,with the eye in primary position there is inability to visualize ≤ 180° of the posterior trabecular meshwork (TM) in the absence of peripheral anterior 4-IOP ≤ 21 as measured by tonometry. 5-Normal visual field on static automated perimetry (SAP) testing. 5-Normal optic nerve head (ONH) appearance on fundus biomicroscopy. 6-Family history of primary angle closure disease.
Exclusion Criteria:
1-Eyes with significant corneal opacity that can impare signal strings of any of the used imaging modalities.
2-Eyes wih history of intraocular surgery (e.g. cataract surgery ,retinal detachment surgery).
3-Eyes with history of laser procedures (e.g.laser peripheral iridotomy). 4-Eyes with anterior segment pathology as iridocyclitis or angle disgenesis 5. Eyes with history of trauma. 6- Eyes with findings suggestive of 2dry cause of glaucoma (e.g. iris or angle neovascularization, any iris or corneal abnormalities, dilated episcleral vessels ).
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: Coorte
- Perspectivas de Tempo: Retrospectivo
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
40 pateint glucoma suspect
ASOCT
|
Anterior segment imaging using RTVue XR 100 Avanti OCT platform (Optovue Inc.,Fairmont, CA).
Anterior segment imaging using Oculus Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany).
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Anterior segment parameters as measured by AS-OCT:
Prazo: 3 months
|
Anterior chamber depth (ACD)..
|
3 months
|
|
Anterior segment parameters as measured by Oculus Pentacam:
Prazo: 3 months
|
Anterior chamber angle (ACA).
|
3 months
|
|
Anterior segment parameters by ASOCT
Prazo: 3 months
|
Angle opening distance at 750 µm (AOD750).
|
3 months
|
|
Anterior segment parameters by OCT
Prazo: 3 months
|
Anterior chamber angle (ACA).
|
3 months
|
|
Pentacam parameters
Prazo: 3 months
|
Anterior chamber volume (ACV).
|
3 months
|
|
Pentacam parameters by Oculus Pentacam:
Prazo: 3 months
|
Anterior chamber depth (ACD).
|
3 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Mohamed Salah, Minia University Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- AC angle angle closure suspect
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .