Anterior Chamber Angle Examination in Angle Closure Suspect Patients

2022년 1월 25일 업데이트: Mohamed Salah, Minia University
The aim of this study is to detect PACG suspects using both AS OCT and Scheimpflug imaging.

연구 개요

상태

완전한

정황

상세 설명

Glaucoma is a form of progressive optic neuropathy and is one of the leading causes of preventable blindness worldwide. The average life span is increasing leading to more individuals developing glaucoma as well as having the disease longer, which makes early detection and management very important.[1] Glaucoma is characterized by loss of retinal ganglion cells (RGCs) recognized as optic nerve head (ONH) changes, corresponding visual field (VF) defects and retinal nerve fiber layer (RNFL) loss. At least 40% of RGCs are lost before the VFs show a defect, hence the emphasis on early diagnosis in the stage of glaucoma suspect.[2] There are two types of glaucoma suspect: Primary Open angle and primary angle closure suspect.(3) Primary angle-closure (PAC) suspects can be detected by the following: the trabecular meshwork can only be seen in 180º or less of anterior chamber angle (AC) by gonioscopy, the intraocular pressure(IOP) remains within normal limits and no structural damage to the optic nerve is present.[4] Time domain Optical coherence tomography (TD-OCT) was initially designed to image the posterior segment and retina, but its capability to generate cross-sectional images of internal biological structures without contacting the ocular surface was quickly adapted to visualize the anterior segment and cornea.[5].

Spectral domain anterior segment OCT (SD-OCT) technology allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Spectral-domain OCT(SD OCT) instruments working at 840 nm can reliably identify fine angle structures such as Schwalbe's line.(6) Scheimpflug imaging also offers non-contact imaging of the anterior segment. Although Scheimpflug photography cannot fully visualize the entire angle, the software available on the Pentacam system (Oculus Optikgeräte, Wetzlar, Germany) provides extrapolated measurements of the anterior chamber volume (ACV), which have shown promise in screening for narrow angles.(7)

연구 유형

관찰

등록 (실제)

40

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Minya, 이집트
        • Minia University Hospital

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

40년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

샘플링 방법

비확률 샘플

연구 인구

Residents of Minia Governorate diagnosed with SLE with renal affection and without renal affection.

설명

Inclusion Criteria:

  • Hyperopes. 2-Shallow AC. 3-With gonioscopy carried out under dim-light conditions without indentation ,with the eye in primary position there is inability to visualize ≤ 180° of the posterior trabecular meshwork (TM) in the absence of peripheral anterior 4-IOP ≤ 21 as measured by tonometry. 5-Normal visual field on static automated perimetry (SAP) testing. 5-Normal optic nerve head (ONH) appearance on fundus biomicroscopy. 6-Family history of primary angle closure disease.

Exclusion Criteria:

  • 1-Eyes with significant corneal opacity that can impare signal strings of any of the used imaging modalities.

    2-Eyes wih history of intraocular surgery (e.g. cataract surgery ,retinal detachment surgery).

    3-Eyes with history of laser procedures (e.g.laser peripheral iridotomy). 4-Eyes with anterior segment pathology as iridocyclitis or angle disgenesis 5. Eyes with history of trauma. 6- Eyes with findings suggestive of 2dry cause of glaucoma (e.g. iris or angle neovascularization, any iris or corneal abnormalities, dilated episcleral vessels ).

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 관찰 모델: 보병대
  • 시간 관점: 회고전

코호트 및 개입

그룹/코호트
개입 / 치료
40 pateint glucoma suspect
ASOCT
Anterior segment imaging using RTVue XR 100 Avanti OCT platform (Optovue Inc.,Fairmont, CA).
Anterior segment imaging using Oculus Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany).

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Anterior segment parameters as measured by AS-OCT:
기간: 3 months
Anterior chamber depth (ACD)..
3 months
Anterior segment parameters as measured by Oculus Pentacam:
기간: 3 months
Anterior chamber angle (ACA).
3 months
Anterior segment parameters by ASOCT
기간: 3 months
Angle opening distance at 750 µm (AOD750).
3 months
Anterior segment parameters by OCT
기간: 3 months
Anterior chamber angle (ACA).
3 months
Pentacam parameters
기간: 3 months
Anterior chamber volume (ACV).
3 months
Pentacam parameters by Oculus Pentacam:
기간: 3 months
Anterior chamber depth (ACD).
3 months

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

수사관

  • 수석 연구원: Mohamed Salah, Minia University Hospital

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2019년 4월 1일

기본 완료 (실제)

2019년 12월 1일

연구 완료 (실제)

2020년 1월 1일

연구 등록 날짜

최초 제출

2022년 1월 7일

QC 기준을 충족하는 최초 제출

2022년 1월 25일

처음 게시됨 (실제)

2022년 1월 26일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2022년 1월 26일

QC 기준을 충족하는 마지막 업데이트 제출

2022년 1월 25일

마지막으로 확인됨

2022년 1월 1일

추가 정보

이 연구와 관련된 용어

키워드

추가 관련 MeSH 약관

기타 연구 ID 번호

  • AC angle angle closure suspect

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

ASOCT에 대한 임상 시험

3
구독하다