Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)
Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.
An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).
調査の概要
研究の種類
入学 (推定)
段階
- 適用できない
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Adult patient, of legal age
- On invasive mechanical ventilation for more than 48 hours
With at least one criterion indicating a high risk of extubation failure:
- Age > 65 years
- Chronic respiratory disease
- Chronic cardiac disease
Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):
- Respiratory rate < 35 bpm
Adequate oxygenation:
- SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
- Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
- Effective cough
- Patient is alert (RASS score -2 to +1), without sedation
- Hemodynamically stable or on the minimum effective dose
- Patient has an invasive arterial pressure catheter for arterial blood sampling
- Informed consent signed by a family member
- Patient is enrolled in or eligible for a social security program
Exclusion Criteria:
- Resuscitation-associated neuromyopathy
- History of neuromuscular disease
- Admission for a neurological condition
- Subjects currently excluded from another study,
- Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
- Staff members who report to the principal investigator
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
他の:TP/HFO/PSV
T piece follow by HFO follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
他の:TP/PSV/HFO
T piece follow by PSV follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
他の:PSV/HFO/TP
PSV follow by HFO follow by T piece
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
他の:PSV/TP/HFO
PSV follow by T piece follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
他の:HFO/TP/PSV
HFO follow by T piece follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
他の:HFO/PSV/TP
HFO follow by PSV follow by TP
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
時間枠:190 min
|
190 min
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Tidal Volume
時間枠:190 min
|
190 min
|
|
Total Positive End-Expiratory Pressure
時間枠:190 min
|
190 min
|
|
Respiratory Rate
時間枠:190 min
|
190 min
|
|
minute ventilation
時間枠:190 min
|
190 min
|
|
Ratio Respiratory rate/ Tidal volume
時間枠:190 min
|
190 min
|
|
product pressure time
時間枠:190 min
|
190 min
|
|
Occlusion pressure (or P 0.1)
時間枠:190 min
|
190 min
|
|
Percentage of success on the weaning test (predefined criteria)
時間枠:190 min
|
190 min
|
その他の成果指標
結果測定 |
時間枠 |
|---|---|
|
Percentage of patients extubated following the series of weaning trials
時間枠:190 min
|
190 min
|
|
Percentage of reintubations within 48 hours after extubation
時間枠:52 hours
|
52 hours
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 38RC25.0307
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。