- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07724392
Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)
Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.
An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Adult patient, of legal age
- On invasive mechanical ventilation for more than 48 hours
With at least one criterion indicating a high risk of extubation failure:
- Age > 65 years
- Chronic respiratory disease
- Chronic cardiac disease
Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):
- Respiratory rate < 35 bpm
Adequate oxygenation:
- SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
- Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
- Effective cough
- Patient is alert (RASS score -2 to +1), without sedation
- Hemodynamically stable or on the minimum effective dose
- Patient has an invasive arterial pressure catheter for arterial blood sampling
- Informed consent signed by a family member
- Patient is enrolled in or eligible for a social security program
Exclusion Criteria:
- Resuscitation-associated neuromyopathy
- History of neuromuscular disease
- Admission for a neurological condition
- Subjects currently excluded from another study,
- Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
- Staff members who report to the principal investigator
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Doble
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: TP/HFO/PSV
T piece follow by HFO follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Otro: TP/PSV/HFO
T piece follow by PSV follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Otro: PSV/HFO/TP
PSV follow by HFO follow by T piece
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Otro: PSV/TP/HFO
PSV follow by T piece follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Otro: HFO/TP/PSV
HFO follow by T piece follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
Otro: HFO/PSV/TP
HFO follow by PSV follow by TP
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
Periodo de tiempo: 190 min
|
190 min
|
Medidas de resultado secundarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Tidal Volume
Periodo de tiempo: 190 min
|
190 min
|
|
Total Positive End-Expiratory Pressure
Periodo de tiempo: 190 min
|
190 min
|
|
Respiratory Rate
Periodo de tiempo: 190 min
|
190 min
|
|
minute ventilation
Periodo de tiempo: 190 min
|
190 min
|
|
Ratio Respiratory rate/ Tidal volume
Periodo de tiempo: 190 min
|
190 min
|
|
product pressure time
Periodo de tiempo: 190 min
|
190 min
|
|
Occlusion pressure (or P 0.1)
Periodo de tiempo: 190 min
|
190 min
|
|
Percentage of success on the weaning test (predefined criteria)
Periodo de tiempo: 190 min
|
190 min
|
Otras medidas de resultado
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Percentage of patients extubated following the series of weaning trials
Periodo de tiempo: 190 min
|
190 min
|
|
Percentage of reintubations within 48 hours after extubation
Periodo de tiempo: 52 hours
|
52 hours
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
- 38RC25.0307
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .