Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)

20 de julio de 2026 actualizado por: University Hospital, Grenoble

Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.

An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).

Descripción general del estudio

Tipo de estudio

Intervencionista

Inscripción (Estimado)

30

Fase

  • No aplica

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Adult patient, of legal age
  • On invasive mechanical ventilation for more than 48 hours
  • With at least one criterion indicating a high risk of extubation failure:

    • Age > 65 years
    • Chronic respiratory disease
    • Chronic cardiac disease
  • Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):

    • Respiratory rate < 35 bpm
    • Adequate oxygenation:

      • SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
      • Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
    • Effective cough
    • Patient is alert (RASS score -2 to +1), without sedation
    • Hemodynamically stable or on the minimum effective dose
  • Patient has an invasive arterial pressure catheter for arterial blood sampling
  • Informed consent signed by a family member
  • Patient is enrolled in or eligible for a social security program

Exclusion Criteria:

  • Resuscitation-associated neuromyopathy
  • History of neuromuscular disease
  • Admission for a neurological condition
  • Subjects currently excluded from another study,
  • Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
  • Staff members who report to the principal investigator

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Otro: TP/HFO/PSV
T piece follow by HFO follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Otro: TP/PSV/HFO
T piece follow by PSV follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Otro: PSV/HFO/TP
PSV follow by HFO follow by T piece
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Otro: PSV/TP/HFO
PSV follow by T piece follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Otro: HFO/TP/PSV
HFO follow by T piece follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Otro: HFO/PSV/TP
HFO follow by PSV follow by TP
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
Periodo de tiempo: 190 min
190 min

Medidas de resultado secundarias

Medida de resultado
Periodo de tiempo
Tidal Volume
Periodo de tiempo: 190 min
190 min
Total Positive End-Expiratory Pressure
Periodo de tiempo: 190 min
190 min
Respiratory Rate
Periodo de tiempo: 190 min
190 min
minute ventilation
Periodo de tiempo: 190 min
190 min
Ratio Respiratory rate/ Tidal volume
Periodo de tiempo: 190 min
190 min
product pressure time
Periodo de tiempo: 190 min
190 min
Occlusion pressure (or P 0.1)
Periodo de tiempo: 190 min
190 min
Percentage of success on the weaning test (predefined criteria)
Periodo de tiempo: 190 min
190 min

Otras medidas de resultado

Medida de resultado
Periodo de tiempo
Percentage of patients extubated following the series of weaning trials
Periodo de tiempo: 190 min
190 min
Percentage of reintubations within 48 hours after extubation
Periodo de tiempo: 52 hours
52 hours

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de enero de 2027

Finalización primaria (Estimado)

1 de enero de 2027

Finalización del estudio (Estimado)

1 de enero de 2027

Fechas de registro del estudio

Enviado por primera vez

20 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

20 de julio de 2026

Publicado por primera vez (Actual)

24 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

24 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

20 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 38RC25.0307

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir