Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)

20 juli 2026 bijgewerkt door: University Hospital, Grenoble

Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.

An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).

Studie Overzicht

Toestand

Nog niet aan het werven

Studietype

Ingrijpend

Inschrijving (Geschat)

30

Fase

  • Niet toepasbaar

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Adult patient, of legal age
  • On invasive mechanical ventilation for more than 48 hours
  • With at least one criterion indicating a high risk of extubation failure:

    • Age > 65 years
    • Chronic respiratory disease
    • Chronic cardiac disease
  • Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):

    • Respiratory rate < 35 bpm
    • Adequate oxygenation:

      • SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
      • Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
    • Effective cough
    • Patient is alert (RASS score -2 to +1), without sedation
    • Hemodynamically stable or on the minimum effective dose
  • Patient has an invasive arterial pressure catheter for arterial blood sampling
  • Informed consent signed by a family member
  • Patient is enrolled in or eligible for a social security program

Exclusion Criteria:

  • Resuscitation-associated neuromyopathy
  • History of neuromuscular disease
  • Admission for a neurological condition
  • Subjects currently excluded from another study,
  • Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
  • Staff members who report to the principal investigator

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Crossover-opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Ander: TP/HFO/PSV
T piece follow by HFO follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Ander: TP/PSV/HFO
T piece follow by PSV follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Ander: PSV/HFO/TP
PSV follow by HFO follow by T piece
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Ander: PSV/TP/HFO
PSV follow by T piece follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Ander: HFO/TP/PSV
HFO follow by T piece follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Ander: HFO/PSV/TP
HFO follow by PSV follow by TP
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
Tijdsspanne: 190 min
190 min

Secundaire uitkomstmaten

Uitkomstmaat
Tijdsspanne
Tidal Volume
Tijdsspanne: 190 min
190 min
Total Positive End-Expiratory Pressure
Tijdsspanne: 190 min
190 min
Respiratory Rate
Tijdsspanne: 190 min
190 min
minute ventilation
Tijdsspanne: 190 min
190 min
Ratio Respiratory rate/ Tidal volume
Tijdsspanne: 190 min
190 min
product pressure time
Tijdsspanne: 190 min
190 min
Occlusion pressure (or P 0.1)
Tijdsspanne: 190 min
190 min
Percentage of success on the weaning test (predefined criteria)
Tijdsspanne: 190 min
190 min

Andere uitkomstmaten

Uitkomstmaat
Tijdsspanne
Percentage of patients extubated following the series of weaning trials
Tijdsspanne: 190 min
190 min
Percentage of reintubations within 48 hours after extubation
Tijdsspanne: 52 hours
52 hours

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

1 januari 2027

Primaire voltooiing (Geschat)

1 januari 2027

Studie voltooiing (Geschat)

1 januari 2027

Studieregistratiedata

Eerst ingediend

20 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

20 juli 2026

Eerst geplaatst (Werkelijk)

24 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

24 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

20 juli 2026

Laatst geverifieerd

1 juli 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • 38RC25.0307

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren