Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)

20. Juli 2026 aktualisiert von: University Hospital, Grenoble

Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.

An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).

Studienübersicht

Status

Noch keine Rekrutierung

Studientyp

Interventionell

Einschreibung (Geschätzt)

30

Phase

  • Unzutreffend

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  • Adult patient, of legal age
  • On invasive mechanical ventilation for more than 48 hours
  • With at least one criterion indicating a high risk of extubation failure:

    • Age > 65 years
    • Chronic respiratory disease
    • Chronic cardiac disease
  • Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):

    • Respiratory rate < 35 bpm
    • Adequate oxygenation:

      • SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
      • Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
    • Effective cough
    • Patient is alert (RASS score -2 to +1), without sedation
    • Hemodynamically stable or on the minimum effective dose
  • Patient has an invasive arterial pressure catheter for arterial blood sampling
  • Informed consent signed by a family member
  • Patient is enrolled in or eligible for a social security program

Exclusion Criteria:

  • Resuscitation-associated neuromyopathy
  • History of neuromuscular disease
  • Admission for a neurological condition
  • Subjects currently excluded from another study,
  • Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
  • Staff members who report to the principal investigator

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Sonstiges: TP/HFO/PSV
T piece follow by HFO follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Sonstiges: TP/PSV/HFO
T piece follow by PSV follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Sonstiges: PSV/HFO/TP
PSV follow by HFO follow by T piece
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Sonstiges: PSV/TP/HFO
PSV follow by T piece follow by HFO
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Sonstiges: HFO/TP/PSV
HFO follow by T piece follow by PSV
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
Sonstiges: HFO/PSV/TP
HFO follow by PSV follow by TP
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph. The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph. The OHD flow rate will be set to 50 L/min. A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
Zeitfenster: 190 min
190 min

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Tidal Volume
Zeitfenster: 190 min
190 min
Total Positive End-Expiratory Pressure
Zeitfenster: 190 min
190 min
Respiratory Rate
Zeitfenster: 190 min
190 min
minute ventilation
Zeitfenster: 190 min
190 min
Ratio Respiratory rate/ Tidal volume
Zeitfenster: 190 min
190 min
product pressure time
Zeitfenster: 190 min
190 min
Occlusion pressure (or P 0.1)
Zeitfenster: 190 min
190 min
Percentage of success on the weaning test (predefined criteria)
Zeitfenster: 190 min
190 min

Andere Ergebnismessungen

Ergebnis Maßnahme
Zeitfenster
Percentage of patients extubated following the series of weaning trials
Zeitfenster: 190 min
190 min
Percentage of reintubations within 48 hours after extubation
Zeitfenster: 52 hours
52 hours

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Januar 2027

Primärer Abschluss (Geschätzt)

1. Januar 2027

Studienabschluss (Geschätzt)

1. Januar 2027

Studienanmeldedaten

Zuerst eingereicht

20. Juli 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

20. Juli 2026

Zuerst gepostet (Tatsächlich)

24. Juli 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

24. Juli 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

20. Juli 2026

Zuletzt verifiziert

1. Juli 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 38RC25.0307

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren