Effect of High-Flow Humidified Oxygen on Ventilatory Work During the Spontaneous Breathing Trial (OTRAVAIL)
Weaning from mechanical ventilation (MV) accounts for a significant portion of the total MV duration, and failure to extubate or delayed extubation increases complications (particularly Ventilator-Associated Pneumonia (VAP)) and mortality. Standard tests (T-piece, Spontaneous Ventilation with Inspiratory Assistance (SV-IA)) have not demonstrated clear superiority, and the T-piece is still widely used despite its limitations. High-flow oxygen (HFO) may reduce ventilatory work and facilitate secretion clearance; however, there is a lack of physiological data in humans with an endotracheal tube in place. This study aims to address this gap prior to a subsequent clinical evaluation.
An experimental, prospective, single-center, 3-period crossover study with randomized sequence order and single-blind design (primary endpoint assessment and statistical analysis were conducted in a blinded manner).
研究概览
研究类型
注册 (估计的)
阶段
- 不适用
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Adult patient, of legal age
- On invasive mechanical ventilation for more than 48 hours
With at least one criterion indicating a high risk of extubation failure:
- Age > 65 years
- Chronic respiratory disease
- Chronic cardiac disease
Capable of undergoing a mechanical ventilation weaning test ("weaning criterion"):
- Respiratory rate < 35 bpm
Adequate oxygenation:
- SpO₂ ≥ 90% with FiO₂ ≤ 40% and PEEP ≤ 8 cm H₂O
- Or PaO₂/FiO₂ ≥ 150 with PEEP ≤ 8 cm H₂O
- Effective cough
- Patient is alert (RASS score -2 to +1), without sedation
- Hemodynamically stable or on the minimum effective dose
- Patient has an invasive arterial pressure catheter for arterial blood sampling
- Informed consent signed by a family member
- Patient is enrolled in or eligible for a social security program
Exclusion Criteria:
- Resuscitation-associated neuromyopathy
- History of neuromuscular disease
- Admission for a neurological condition
- Subjects currently excluded from another study,
- Persons referred to in Articles L1121-5 through L1121-8 of the CSP (corresponding to all protected persons: pregnant women, women in labor, breastfeeding mothers, persons deprived of liberty by judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L. 3213-1 who are not covered by the provisions of Article L. 1121-8, persons admitted to a health or social care facility for purposes other than research, minors, and persons subject to a legal protection order or unable to give informed consent).
- Staff members who report to the principal investigator
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
其他:TP/HFO/PSV
T piece follow by HFO follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
其他:TP/PSV/HFO
T piece follow by PSV follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
其他:PSV/HFO/TP
PSV follow by HFO follow by T piece
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
其他:PSV/TP/HFO
PSV follow by T piece follow by HFO
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
其他:HFO/TP/PSV
HFO follow by T piece follow by PSV
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
|
其他:HFO/PSV/TP
HFO follow by PSV follow by TP
|
The endotracheal tube will be disconnected from the ventilator, and a T-piece (Teleflex, Trach-Vent +®) with oxygen delivery
The endotracheal tube will be connected to the pneumotachograph.
The ventilator settings will be adjusted as follows: VS mode, inspiratory support at 7 cmH₂O, PEEP at 0 cmH₂O.
The endotracheal tube will be disconnected from the ventilator, and an OHD delivery device normally used for tracheostomies (Fisher & Paykel, Optiflow+®) will be connected to the pneumotachograph.
The OHD flow rate will be set to 50 L/min.
A Monnal T60 ventilator (Air Liquide Healthcare) will be used for OHD administration.
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Respiratory work during the weaning test, defined as the energy expended to inhale and exhale a respiratory gas, measured in joules per liter per minute.
大体时间:190 min
|
190 min
|
次要结果测量
结果测量 |
大体时间 |
|---|---|
|
Tidal Volume
大体时间:190 min
|
190 min
|
|
Total Positive End-Expiratory Pressure
大体时间:190 min
|
190 min
|
|
Respiratory Rate
大体时间:190 min
|
190 min
|
|
minute ventilation
大体时间:190 min
|
190 min
|
|
Ratio Respiratory rate/ Tidal volume
大体时间:190 min
|
190 min
|
|
product pressure time
大体时间:190 min
|
190 min
|
|
Occlusion pressure (or P 0.1)
大体时间:190 min
|
190 min
|
|
Percentage of success on the weaning test (predefined criteria)
大体时间:190 min
|
190 min
|
其他结果措施
结果测量 |
大体时间 |
|---|---|
|
Percentage of patients extubated following the series of weaning trials
大体时间:190 min
|
190 min
|
|
Percentage of reintubations within 48 hours after extubation
大体时间:52 hours
|
52 hours
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- 38RC25.0307
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
在美国制造并从美国出口的产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.