Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock

Pierre-Grégoire Guinot, Eugénie Bernard, Mélanie Levrard, Hervé Dupont, Emmanuel Lorne, Pierre-Grégoire Guinot, Eugénie Bernard, Mélanie Levrard, Hervé Dupont, Emmanuel Lorne

Abstract

Introduction: Gradual reduction of the dosage of norepinephrine (NE) in patients with septic shock is usually left to the physician's discretion. No hemodynamic indicator predictive of the possibility of decreasing the NE dosage is currently available at the bedside. The respiratory pulse pressure variation/respiratory stroke volume variation (dynamic arterial elastance (Eadyn)) ratio has been proposed as an indicator of vascular tone. The purpose of this study was to determine whether Eadyn can be used to predict the decrease in arterial pressure when decreasing the NE dosage in resuscitated sepsis patients.

Methods: A prospective study was carried out in a university hospital intensive care unit. All consecutive patients with septic shock monitored by PICCO2 for whom the intensive care physician planned to decrease the NE dosage were enrolled. Measurements of hemodynamic and PICCO2 variables were obtained before/after decreasing the NE dosage. Responders were defined by a >15% decrease in mean arterial pressure (MAP).

Results: In total, 35 patients were included. MAP decreased by >15% after decreasing the NE dosage in 37% of patients (n = 13). Clinical characteristics appeared to be similar between responders and nonresponders. Eadyn was lower in responders than in nonresponders (0.75 (0.69 to 0.85) versus 1 (0. 83 to 1.22), P <0.05). Baseline Eadyn was correlated with NE-induced MAP variations (r = 0.47, P = 0.005). An Eadyn less than 0.94 predicted a decrease in arterial pressure, with an area under the receiver-operating characteristic curve of 0.87 (95% confidence interval (95% CI): 0.72 to 0.96; P <0.0001), 100% sensitivity, and 68% specificity.

Conclusions: In sepsis patients treated with NE, Eadyn may predict the decrease in arterial pressure in response to NE dose reduction. Eadyn may constitute an easy-to-use functional approach to arterial-tone assessment, which may be helpful to identify patients likely to benefit from NE dose reduction.

Figures

Figure 1
Figure 1
Dynamic arterial elastance (Eadyn) in arterial-pressure responders and nonresponders.
Figure 2
Figure 2
Receiver operating characteristic curves to discriminate decrease in arterial pressure with decreasing doses of norepinephrine. Eadyn, dynamic arterial elastance; C, arterial compliance; SVR, systemic vascular resistance.

References

    1. Angus DC, van der Poll T. Severe sepsis and septic shock. N Engl J Med. 2013;369:840–51. doi: 10.1056/NEJMra1208623.
    1. Vincent JL, De Backer D. Circulatory shock. N Engl J Med. 2013;369:1726–34. doi: 10.1056/NEJMra1208943.
    1. De Backer D, Biston P, Devriendt J, Madi C, Chochrad D, Aldecoa C, et al. Comparison of dopamine and norepinephrine in the treatment of shock. N Engl J Med. 2010;362:779–89. doi: 10.1056/NEJMoa0907118.
    1. Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, et al. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock. Crit Care Med. 2013;41:580–637. doi: 10.1097/CCM.0b013e31827e83af.
    1. Vincent JL, Sakr Y, Sprung CL, Ranieri VM, Reinhart K, Gerlach H, et al. Sepsis in European intensive care units: results of the SOAP study. Crit Care Med. 2006;34:344–53. doi: 10.1097/01.CCM.0000194725.48928.3A.
    1. Datta P, Magder S. Hemodynamic response to norepinephrine with and without inhibition of nitric oxide synthase in porcine endotoxemia. Am J Respir Crit Care Med. 1999;160:1987–93. doi: 10.1164/ajrccm.160.6.9808019.
    1. Imai Y, Satoh K, Taira N. Role of the peripheral vasculature in changes in venous return caused by isoproterenol, norepinephrine, and methoxamine in anesthetized dogs. Circ Res. 1978;43:553–61. doi: 10.1161/01.RES.43.4.553.
    1. Hamzaoui O, Georger JF, Monnet X, Ksouri H, Maizel J, Richard C. Early administration of norepinephrine increases cardiac preload and cardiac output in septic patients with life-threatening hypotension. Crit Care. 2010;14:R142. doi: 10.1186/cc9207.
    1. Merouani M, Guignard B, Vincent F, Borron SW, Karoubi P, Fosse JP, et al. Norepinephrine weaning in septic shock patients by closed loop control based on fuzzy logic. Crit Care. 2008;12:R155. doi: 10.1186/cc7149.
    1. Pinsky MR. Functional hemodynamic monitoring: applied physiology at the bedside. In: Vincent JL, editor. Yearbook of Intensive Care and Emergency Medicine. Heidelberg, Germany: Springer-Verlag; 2012. pp. 534–51.
    1. Pinsky MR. Heart lung interactions during mechanical ventilation. Curr Opin Crit Care. 2012;18:256–60. doi: 10.1097/MCC.0b013e3283532b73.
    1. Monge García MI, Gil Cano A, GraciaRomero M. Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care. 2011;15:R15. doi: 10.1186/cc9420.
    1. Vos JJ, Kalmar AF, Struys MM, Wietasch JK, Hendriks HG, Scheeren TW. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection. Br J Anaesth. 2013;110:940–6. doi: 10.1093/bja/aes508.
    1. Pinsky MR. Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastance. Crit Care. 2011;15:120. doi: 10.1186/cc9986.
    1. Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, et al. Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans. Am J Physiol. 1998;274:H500–5.
    1. Hadian M, Severyn D, Pinsky MR. The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients. J Crit Care. 2011;26:328. doi: 10.1016/j.jcrc.2010.08.018.
    1. Hallock P, Benson IC. Studies on the elastic properties of human isolated aorta. J Clin Invest. 1937;16:595–602. doi: 10.1172/JCI100886.
    1. Monnet X, Jabot J, Maizel J, Richard C, Teboul JL. Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock patients. Crit Care Med. 2011;39:689–94. doi: 10.1097/CCM.0b013e318206d2a3.
    1. Maas JJ, de Wilde RB, Aarts LP, Pinsky MR, Jansen JR. Determination of vascular waterfall phenomenon by bedside measurement of mean systemic filling pressure and critical closing pressure in the intensive care unit. Anesth Analg. 2012;114:803–10. doi: 10.1213/ANE.0b013e318247fa44.
    1. Persichini R, Silva S, Teboul JL, Jozwiak M, Chemla D, Richard C, et al. Effects of norepinephrine on mean systemic pressure and venous return in human septic shock. Crit Care Med. 2012;40:3146–53. doi: 10.1097/CCM.0b013e318260c6c3.
    1. Ritter S, Rudiger A, Maggiorini M. Transpulmonary thermodilution-derived cardiac function index identifies cardiac dysfunction in acute heart failure and septic patients: an observational study. Crit Care. 2009;213:R133. doi: 10.1186/cc7994.
    1. Cecconi M, Monge García MI, Gracia Romero M, Mellinghoff J, Caliandro F, Grounds RM, et al. The use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration. Anesth Analg. 2014;ᅟ:ᅟ.
    1. Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies, with specific reference to the measurement of cardiac output. Crit Care. 2009;13:201. doi: 10.1186/cc7129.