Atrioventricular Interval Extension Is Highly Efficient in Preventing Unnecessary Right Ventricular Pacing in Sinus Node Disease: A Randomized Cross-Over Study Versus Dual- to Atrial Single-Chamber Mode Switch

Valeria Calvi, Ennio C Pisanò, Marco Brieda, Donato Melissano, Bruno Castaldi, Ciro Guastaferro, Gerardo Nigro, Michela Madalosso, Daniela Orsida, Nicola Rovai, Alessio Gargaro, Alessandro Capucci, Valeria Calvi, Ennio C Pisanò, Marco Brieda, Donato Melissano, Bruno Castaldi, Ciro Guastaferro, Gerardo Nigro, Michela Madalosso, Daniela Orsida, Nicola Rovai, Alessio Gargaro, Alessandro Capucci

Abstract

Objectives: This study sought to compare the Intrinsic Rhythm Support (IRSplus) and Ventricular Pace Suppress (VpS) in terms of right ventricular pacing percentage (VP %), mean atrioventricular interval (MAVI), atrial fibrillation, and cardiac volumes.

Background: Modern pacemakers are provided with algorithms for reducing unnecessary ventricular pacing. These may be classified as: periodic search for intrinsic atrioventricular (AV) conduction prolonging the AV delay accordingly; or DDD-ADI mode switch. The IRSplus and VpS algorithms belong to the former and latter classes, respectively.

Methods: Patients with sick sinus dysfunction without evidence of II/III degree AV block were 1:1 randomized to 6-month periods of either IRSplus or VpS, and then crossed over. Subsequent follow-ups were at the 12th month after randomization for device data retrieving, and at the 18th month with the same device programming for echocardiographic assessment.

Results: A total of 230 patients (62% males, median age 75 years [interquartile range: 69 to 79 years]) were enrolled. At a linear mixed-model analysis with order of treatment and investigational sites as nested random effects, differences in VP% and MAVI reached statistical significance: VP% was 1% (0% to 11%) during IRSplus and 3% (0% to 26%) during VpS (p = 0.029); MAVI was 225 ms (198 to 253 ms) during IRSplus and 214 ms (188 to 240 ms) during VpS (p = 0.014). No differences were observed in atrial fibrillation burden and incidence, ejection fraction, and cardiac volumes.

Conclusions: Both IRSplus and VpS algorithms ensured VP% ≤3% in most patients with sinus node dysfunction and preserved AV conduction. The IRSplus was slightly more efficient in reducing VP% at the expense of a small MAVI increase, with statistical but clinically insignificant differences. (Ventricular Pace Suppression Versus Intrinsic Rhythm Support Study; NCT01528657).

Keywords: atrioventricular hysteresis; dual-chamber pacemaker; mode-switch algorithm; right ventricular pacing; sinus node dysfunction.

Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Source: PubMed

3