Conditions for laryngeal mask airway placement in terms of oropharyngeal leak pressure: a comparison between blind insertion and laryngoscope-guided insertion

Go Wun Kim, Jong Yeop Kim, Soo Jin Kim, Yeo Rae Moon, Eun Jeong Park, Sung Yong Park, Go Wun Kim, Jong Yeop Kim, Soo Jin Kim, Yeo Rae Moon, Eun Jeong Park, Sung Yong Park

Abstract

Background: Insertion under laryngoscopic guidance has been used to achieve ideal positioning of the laryngeal mask airway (LMA). However, to date, the efficacy of this technique has been evaluated only using fiberoptic evaluation, and the results have been conflicting. Other reliable tests to evaluate the efficacy of this technique have not been established. Recently, it has been suggested that the accuracy of LMA placement can be determined by clinical signs such as oropharyngeal leak pressure (OPLP). The aim of this study was to assess the efficacy of LMA insertion under laryngoscopic guidance using OPLP as an indicator.

Methods: After approved by the institutional ethics committee, a prospective comparison of 100 patients divided into 2 groups (50 with blind technique and 50 with the laryngoscope technique) were evaluated. An LMA (LarySeal™, Flexicare medical Ltd., UK) was inserted using the blind approach in the blind insertion group and using laryngoscopy in the laryngoscope-guided insertion group. The OPLP, fiberoptic position score, whether the first attempt at LMA insertion was successful, time taken for insertion, ease of LMA insertion, and adverse airway events were recorded.

Results: Data were presented as mean ± standard deviation. The OPLP was higher in the laryngoscope-guided insertion group than in the blind insertion group (21.4 ± 8.6 cmH2O vs. 18.1 ± 6.1 cmH2O, p = 0.031). The fiberoptic position score, rate of success in the first attempt, ease of insertion, and pharyngolaryngeal adverse events were similar between both groups. The time taken for insertion of the LMA was significantly longer in the laryngoscope-guided insertion group, compared to blind insertion group (35.9 ± 9.5 s vs. 28.7 ± 9.5 s, p < 0.0001).

Conclusion: Laryngoscope-guided insertion of LMA improves the airway seal pressure compared to blind insertion. Our result suggests that it may be a useful technique for LMA insertion.

Trial registration: cris.nih.go.kr , identifier: KCT0001945 (2016-06-17).

Keywords: Blind insertion; Equipment and supplies; Laryngeal masks; Laryngoscopy.

Conflict of interest statement

Ethics approval and consent to participate

This study was approved by the Institutional Review Board of Ajou University Hospital (Ref: AJIRB-MED-DEO-16-072) and registered at http://cris.nih.go.kr (REF: KCT0001945). Written informed consent was obtained from each patient.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests or disclosures.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Figures

Fig. 1
Fig. 1
The CONSORT flow diagram

References

    1. Seet E, Rajeev S, Firoz T, Yousaf F, Wong J, Wong DT, et al. Safety and efficacy of laryngeal mask airway supreme versus laryngeal mask airway ProSeal: a randomized controlled trial. Eur J Anaesthesiol. 2010;27:602–607. doi: 10.1097/EJA.0b013e32833679e3.
    1. Francksen H, Bein B, Cavus E, Renner J, Scholz J, Steinfath M, et al. Comparison of LMA unique, Ambu laryngeal mask and soft seal laryngeal mask during routine surgical procedures. Eur J Anaesthesiol. 2007;24:134–140. doi: 10.1017/S0265021506001219.
    1. Brain AI. The laryngeal mask-a new concept in airway management. Br J Anaesth. 1983;55:801–805. doi: 10.1093/bja/55.8.801.
    1. Füllekrug B, Pothmann W, Werner C, Schulte am Esch J. The laryngeal mask airway: anesthetic gas leakage and fiberoptic control of positioning. J Clin Anesth. 1993;5:357–363. doi: 10.1016/0952-8180(93)90097-X.
    1. Campbell RL, Biddle C, Assudmi N, Campbell JR, Hotchkiss M. Fiberoptic assessment of laryngeal mask airway placement: blind insertion versus direct visual epiglottoscopy. J Oral Maxillofac Surg. 2004;62:1108–1113. doi: 10.1016/j.joms.2003.10.014.
    1. Chandan SN, Sharma SM, Raveendra US, Rajendra Prasad B. Fiberoptic assessment of laryngeal mask airway placement: a comparison of blind insertion and insertion with the use of a laryngoscope. J Maxillofac Oral Surg. 2009;8:95–98. doi: 10.1007/s12663-009-0025-8.
    1. Brimacombe J, Keller C. Stability of the LMA-ProSeal and standard laryngeal mask airway in different head and neck positions: a randomized crossover study. Eur J Anaesthesiol. 2003;20:65–69. doi: 10.1097/00003643-200301000-00012.
    1. Keller C, Brimacombe JR, Keller K, Morris R. Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients. Br J Anaesth. 1999;82:286–287. doi: 10.1093/bja/82.2.286.
    1. Beleña JM, Núñez M, Anta D, Carnero M, Gracia JL, Ayala JL, et al. Comparison of laryngeal mask airway supreme and laryngeal mask airway Proseal with respect to oropharyngeal leak pressure during laparoscopic cholecystectomy: a randomised controlled trial. Eur J Anaesthesiol. 2013;30:119–123. doi: 10.1097/EJA.0b013e32835aba6a.
    1. Eschertzhuber S, Brimacombe J, Hohlrieder M, Keller C. The laryngeal mask airway supreme-a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients. Anaesthesia. 2009;64:79–83. doi: 10.1111/j.1365-2044.2008.05682.x.
    1. Kim HJ, Lee K, Bai S, Kim MH, Oh E, Yoo YC. Influence of head and neck position on ventilation using the air-Q® SP airway in anaesthetized paralysed patients: a prospective randomized crossover study. Br J Anaesth. 2017;118:452–457. doi: 10.1093/bja/aew448.
    1. Gasteiger L, Ofner S, Stögermüller B, Ziegler B, Brimacombe J, Keller C. Randomized crossover study assessing oropharyngeal leak pressure and fiber optic positioning: laryngeal mask airway supreme™ versus laryngeal tube LTS II™ size 2 in non-paralyzed anesthetized children. Anaesthesist. 2016;65:585–589. doi: 10.1007/s00101-016-0192-1.
    1. Joe HB, Kim JY, Kwak HJ, Oh SE, Lee SY, Park SY. Effect of sex differences in remifentanil requirements for the insertion of a laryngeal mask airway during propofol anesthesia: a prospective randomized trial. Medicine. 2016;95:e5032. doi: 10.1097/MD.0000000000005032.
    1. Brimacombe J. Berry a. a proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg. 1993;76:457.
    1. Brimacombe J, Berry A. Insertion of the laryngeal mask airway-a prospective study of four techniques. Anaesth Intensive Care. 1993;21:89–92.
    1. Park JH, Lee JS, Nam SB, Ju JW, Kim MS. Standard versus rotation technique for insertion of Supraglottic airway devices: systematic review and meta-analysis. Yonsei Med J. 2016;57:987–997. doi: 10.3349/ymj.2016.57.4.987.
    1. Jeon YT, Na HS, Park SH, Oh AY, Park HP, Yun MJ, et al. Insertion of the ProSeal laryngeal mask airway is more successful with the 90 degrees rotation technique. Can J Anaesth. 2010;57:211–215. doi: 10.1007/s12630-009-9241-4.
    1. Ghai B, Wig J. Comparison of different techniques of laryngeal mask placement in children. Curr Opin Anaesthesiol. 2009;22:400–404. doi: 10.1097/ACO.0b013e3283294d06.
    1. Joshi S, Sciacca RR, Solanki DR, Young WL, Mathru MM. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology. 1998;89:1141–1146. doi: 10.1097/00000542-199811000-00014.
    1. Xue FS, Mao P, Liu HP, Yang QY, Li CW, He N, et al. The effects of head flexion on airway seal, quality of ventilation and orogastric tube placement using the ProSeal laryngeal mask airway. Anaesthesia. 2008;63:979–985. doi: 10.1111/j.1365-2044.2008.05490.x.
    1. Gupta K, Rastogi B, Gupta PK, Singh I, Singh VP, Jain M. Dexmedetomidine infusion as an anesthetic adjuvant to general anesthesia for appropriate surgical field visibility during modified radical mastectomy with i-gel®: a randomized control study. Korean J Anesthesiol. 2016;69:573–578. doi: 10.4097/kjae.2016.69.6.573.
    1. Goldmann K, Hoch N, Wulf H. Influence of neuromuscular blockade on the airway leak pressure of the ProSeal laryngeal mask airway. Anasthesiol Intensivmed Notfallmed Schmerzther. 2006;41:228–232. doi: 10.1055/s-2005-921200.

Source: PubMed