Reliability and validity of 30-15 intermittent fitness test for cardiorespiratory fitness assessment among infantry members of Slovenian armed forces: A study protocol

Armin H Paravlic, Bostjan Simunic, Rado Pisot, Samo Rauter, Janez Vodicar, Armin H Paravlic, Bostjan Simunic, Rado Pisot, Samo Rauter, Janez Vodicar

Abstract

Introduction: Cardiorespiratory fitness (CRF) testing is routinely performed by most armed and tactical forces around the world as part of their recruitment process for new members or simply as an annual examination of their personnel. A 2-mile run (2MR) test is among the most commonly used. However, as it is performed outdoors, weather, climate, and terrain can influence the results and often limit the maximum performance. Also, this test has been shown to be difficult for individuals because the pacing strategy is self-paced. As such, it does not reflect the real situation on the battlefield, where most activities are externally driven by the environment and the enemy. Therefore, we believe that the 30-15 Intermittent Fitness Test (30-15IFT) may be a suitable tool for measuring CRF and battle readiness of military personnel. Moreover, given the importance of visual attention to military personnel we aim to investigate the differences in visual attention between better and less physically prepared infantry members and its corresponding response to maximal endurance running test.

Methods and analysis: This randomized cross-over study using a within-subjects test-retest design will enroll 32 infantry members of the Slovenian Armed Forces. To investigate the reliability and validity of the 30-15IFT test, an incremental treadmill test (TR), a 2MR test, and two identical 30-15IFT will be performed in randomized order. Additionally, participants will be subsequently divided into two groups based on their score on the Army Physical Fitness Test (APFT), whereas differences in visual attention will be assessed by using the d2 test. The primary analysis will assess differences in key physiological outcomes between the different CRF tests (TR vs. 2MR vs. 30-15IFT). In addition, the relative reliability of all dependent variables between two 30-15IFT trials will be estimated by interclass correlation coefficient (ICC), while relationship between maximal oxygen uptake, heart rate and maximal running speed of 30-15IFT, TR and 2MR will be assessed using Pearson's correlation.

Ethics and dissemination: Ethical approval was obtained from the National Medical Ethics Committee (reference number: 0120-495/2021/6). The results of the proposed study will be disseminated through publication in peer-reviewed journals.

Clinical trial registration: [www.ClinicalTrials.gov], identifier [NCT05218798].

Keywords: 30-15 intermittent fitness test; military personal; running endurance; validation; visual attention.

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Copyright © 2022 Paravlic, Simunic, Pisot, Rauter and Vodicar.

References

    1. Aandstad A., Holme I., Berntsen S., Anderssen S. A. (2011). Validity and reliability of the 20 meter shuttle run test in military personnel. Mil. Med. 176 513–518. 10.7205/MILMED-D-10-00373
    1. Albouaini K., Egred M., Alahmar A., Wright D. J. (2007). Cardiopulmonary exercise testing and its application. Postgrad. Med. J. 83 675–682. 10.1136/hrt.2007.121558
    1. Bates M. E., Lemay E. P. (2004). The d2 Test of Attention: Construct validity and extensions in scoring techniques. J. Int. Neuropsychol. Soc. 10 392–400. 10.1017/S135561770410307X
    1. Borg G. A. V. (1982). Borg psychophysical bases of perceived exertion. Med. Sci. Sports Exerc. 14 377–381.
    1. Borszcz F. K., Tramontin A. F., de Souza K. M., Carminatti L. J., Costa V. P. (2018). Physiological correlations with short, medium, and long cycling time-trial performance. Res. Q. Exerc. Sport 89 120–125. 10.1080/02701367.2017.1411578
    1. Buchheit M. (2008). The 30-15 intermittent fitness test: accuracy for individualizing interval training of young intermittent sport players. Strength Cond. J. 22 365–374. 10.1519/JSC.0b013e3181635b2e
    1. Buchheit M. (2010). The 30–15 intermittent fitness test: 10 year review the 30-15 intermittent fitness Test: 10 year review. Myorobie J. 1 1–9. 10.1186/s13102-017-0081-1
    1. Buchheit M., Lefebvre B., Laursen P. B., Ahmaidi S. (2011). Reliability, usefulness, and validity of the 30–15 intermittent ice test in young elite ice hockey players. J. Strength Cond. Res. 25 1457–1464. 10.1519/JSC.0b013e3181d686b7
    1. Bujang M. A., Baharum N. (2017). A simplified guide to determination of sample size requirements for estimating the value of intraclass correlation coefficient: A review. Arch. Orofac. Sci. 12 1–11.
    1. Canino M. C., Cohen B. S., Redmond J. E., Sharp M. A., Zambraski E. J., Foulis S. A. (2018). The relationship between soldier performance on the two-mile run and the 20-m shuttle run test. Mil. Med. 183 e182–e187. 10.1093/milmed/usx081
    1. Cohen J. (1988). Statistical power analysis for the behavioral sciences, 2nd Editio Edn. Hillsdale NJ: Lawrence Erlbaum Associates.
    1. Dawes J., Lentine T., Johnson Q., Lockie R., Orr R. (2021). Strength and conditioning program design considerations for law enforcement officers. Strength Cond. J. 43 110–114. 10.1519/SSC.0000000000000680
    1. Herrador Colmenero M., Fernández Vicente G., Ruíz Ruíz J. (2014). Assessment of physical fitness in military and security forces: a systematic review. Eur. J. Hum. Mov. 32 3–28. 10.21134/eurjhm.2014.32.317
    1. Hopkins W. G. (2000). Measures of reliability in sports medicine and science. Sport. Med. 30 1–15. 10.2165/00007256-200030010-00001
    1. Hopkins W. (2007). Reliability from consecutive pairs of trials (Excel spreadsheet). A new view of statistics. . Internet Soc. Sport Sci. 11, 23–36.
    1. Jones A. M., Doust J. H. (1996). A 1% treadmill grade most accurately reflects the energetic cost of outdoor running. J. Sports Sci. 14 321–327. 10.1080/02640419608727717
    1. Knapik J., Whitfield E. (2014). History of United States army physical fitness and physical readiness Testing. U.S. Army Med. Dep. J. 8 41–51.
    1. McGuire M. B., Lockie R. G. (2021). Motor skill, movement competency, and physical fitness assessments for reserve officers’. Strength Cond. J. 43 75–83. 10.1519/ssc.0000000000000575
    1. Mohorič U., Šibila M., Štrumbelj B. (2021). Positional differences in some physiological parameters obtained by the incremental field endurance test among elite handball players. Kinesiology 53 3–11. 10.26582/k.53.1.1
    1. Newell K. M. (1989). On task and theory specificity. J. Mot. Behav. 21 92–96. 10.1080/00222895.1989.10735467
    1. Orr R. M., Lockie R., Milligan G., Lim C., Dawes J. (2021). Use of physical fitness assessments in tactical populations. Strength Cond. J. [Epub ahead of print]. 10.1519/ssc.0000000000000656
    1. Poole D. C., Richardson R. S. (1997). Determinants of oxygen uptake: Implications for exercise testing. Sport. Med. 24 308–320. 10.2165/00007256-199724050-00003
    1. Rabbani A., Buchheit M. (2015). “Heart rate-based versus speed-based high-intensity interval training in young soccer players,” in International Research in Science and Soccer II, eds Favero T., Drust B., Dawson B. (Milton Park: Routledge; ).
    1. Rossiter H. B., Kowalchuk J. M., Whipp B. J. (2006). A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exercise. J. Appl. Physiol. 100 764–770. 10.1152/japplphysiol.00932.2005
    1. Seino S., Shinkai S., Iijima K., Obuchi S., Fujiwara Y., Yoshida H., et al. (2015). Reference values and age differences in body composition of community-dwelling older japanese men and women: a pooled analysis of four cohort studies. PLoS One 10:e0131975. 10.1371/journal.pone.0131975
    1. Taylor R. (1990). Interpretation of the Correlation Coefficient: A Basic Review. J. Diagn. Med. Sonogr. 6 35–39. 10.1177/875647939000600106

Source: PubMed

3
購読する