A novel surface electrocardiogram-based marker of ventricular arrhythmia risk in patients with ischemic cardiomyopathy

William B Nicolson, Gerry P McCann, Peter D Brown, Alastair J Sandilands, Peter J Stafford, Fernando S Schlindwein, Nilesh J Samani, G André Ng, William B Nicolson, Gerry P McCann, Peter D Brown, Alastair J Sandilands, Peter J Stafford, Fernando S Schlindwein, Nilesh J Samani, G André Ng

Abstract

Background: Better sudden cardiac death risk markers are needed in ischemic cardiomyopathy (ICM). Increased heterogeneity of electrical restitution is an important mechanism underlying the risk of ventricular arrhythmia (VA). Our aim was to develop and test a novel quantitative surface electrocardiogram-based measure of VA risk in patients with ICM: the Regional Restitution Instability Index (R2I2).

Methods and results: R2I2, the mean of the standard deviation of residuals from the mean gradient for each ECG lead at a range of diastolic intervals, was measured retrospectively from high-resolution 12-lead ECGs recorded during an electrophysiology study. Patient groups were as follows: Study group, 26 patients with ICM being assessed for implantable defibrillator; Control group, 29 patients with supraventricular tachycardia undergoing electrophysiology study; and Replication group, 40 further patients with ICM. R2I2 was significantly higher in the Study patients than in Controls (mean ± standard error of the mean: 1.09±0.06 versus 0.63±0.04, P<0.001). Over a median follow-up period of 23 months, 6 of 26 Study group patients had VA or death. R2I2 predicted VA or death independently of demographic factors, electrophysiology study result, left ventricular ejection fraction, or QRS duration (Cox model, P=0.029). R2I2 correlated with peri-infarct zone as assessed by cardiac magnetic resonance imaging (r=0.51, P=0.024). The findings were replicated in the Replication group: R2I2 was significantly higher in 11 of 40 Replication patients experiencing VA (1.18±0.10 versus 0.92±0.05, P=0.019). In combined analysis of ICM cohorts, R2I2 ≥1.03 identified subjects with significantly higher risk of VA or death (43%) compared with R2I2 <1.03 (11%) (P=0.004).

Conclusions: In this pilot study, we have developed a novel VA risk marker, R2I2, and have shown that it correlated with a structural measure of arrhythmic risk and predicted risk of VA or death in patients with ICM. R2I2 may improve risk stratification and merits further evaluation. (J Am Heart Assoc. 2012;1:e001552 doi: 10.1161/JAHA.112.001552.).

Keywords: electrical restitution; electrocardiography; implantable cardioverter defibrillator; risk factors; sudden, death.

Figures

Figure 1.
Figure 1.
Technique for measurement of diastolic interval surrogate: Tpeak to QRS onset (TpQ) and APD surrogate: QRS onset to Tpeak (QTp). A. When an S2 arrives after the Tpeak the TpQ and QTp are measured as shown on the left of the diagram. B. If the S2 occurs before the Tpeak the TpQ is effectively negative. In this case it is measured by subtracting the QTp-1 interval (QTp for the last drive cycle beat) from the QQ, in the example above this would give a TpQ close to zero.
Figure 2.
Figure 2.
Explanation of the R2I2 calculation and demonstration of the body surface restitution relation. A. Plot of QRS onset to Tpeak (QTp) against Tpeak to QRS onset (TpQ) for representative ECG leads: I (lateral), II (inferior) and V2 (anterior) to explain the Regional Restitution Instability Index (R2I2) calculation in a typical study patient. For each lead, the QTp/TpQ gradient (least-squares regression) was calculated over a 40 ms segment of TpQ range. This segment was then scanned over the range of TpQ with available data to produce gradients at 10-ms intervals (example gradients are shown for lead V2). The difference of the gradient from the mean gradient in each 40 ms segment was calculated. The standard deviation of these values was taken as a measure of APD restitution heterogeneity in each lead. The mean of this was then taken as the R2I2. B. Mean data points for the individual ECG leads from the combined ICM cohorts were calculated and an area graph of the standard error of the mean has been plotted for the same representative leads as in A.
Figure 3.
Figure 3.
Endocardial and epicardial borders are drawn; then a large representative area of “normal myocardium” and a small area of “peak scar” are selected as shown in A. Software analysis identifies all voxels with signal intensity >2 standard deviations above “normal myocardium” mean intensity and voxels with signal intensity >50% of the “peak scar” are subtracted from this to obtain the PIZ. Identified voxels that are not in the region of an infarct are discarded.
Figure 4.
Figure 4.
Scatter plot for Regional Restitution Instability Index (R2I2) in Control, Primary Study and Replication groups, the line indicates the value chosen to separate a positive and negative R2I2 result and filled squares identify patients who reached the endpoints of VA/death (Primary Study group) or VA (Replication group) during follow-up.
Figure 5.
Figure 5.
Plot of Regional Restitution Instability Index (R2I2) against peri-infarct zone (PIZ) in each of the 19 Primary Study group patients for whom paired data were available. Lines are drawn at the optimal cut-off values for both parameters. A least-squares regression line demonstrates significant correlation (r=0.51, P=0.024).
Figure 6.
Figure 6.
Receiver operating characteristic curve for Regional Restitution Instability Index (R2I2) in Primary Study group: VA/death versus VA-free survival.
Figure 7.
Figure 7.
Kaplan-Meier survival curve for combined Primary Study and Replication groups showing a significantly higher rate of VA in a “high-risk” group with Regional Restitution Instability Index (R2I2)>=1.03 compared with the “low risk” group with R2I2P=0.003, log rank test).
Figure 8.
Figure 8.
Diagram shows the last beat of the drive train and the S1 S2 coupling interval at 400, 380, 360 and 340 ms for leads V2 and III. Demonstration of regional heterogeneity in repolarization: little change is seen in V2 and the QRS onset to Tpeak (QTp) is stable, while lead III is seen to fragment with 2 peaks and variable QTp. This Primary Study group patient had an R2I2 of 1.63 and had VA during follow-up.

References

    1. Myerburg RJ, Mitrani RM, Kessler KM, Castellanos A. Frequency of sudden cardiac death and profiles of risk. Am J Cardiol. 1997;80:10F-19F
    1. Kusmirek SL, Gold MR. Sudden cardiac death: the role of risk stratification. Am Heart J. 2007;153:25-33
    1. Sanders GD, Al-Khatib SM, Berliner E, Bigger JT, Buxton AE, Califf RM, Carlson M, Curtis AB, Curtis JP, Domanski M, Fain E, Gersh BJ, Gold MR, Goldberger J, Haghighi-Mood A, Hammill SC, Harder J, Healey J, Hlatky MA, Hohnloser SH, Lee KL, Mark DB, Mitchell B, Phurrough S, Prystowsky E, Smith JM, Stockbridge N, Temple R. Preventing tomorrow's sudden cardiac death today, part II: Translating sudden cardiac death risk assessment strategies into practice and policy. Am Heart J. 2007;153:951-959
    1. Han J, Moe GK. Nonuniform recovery of excitability in ventricular muscle. Circ Res. 1964;14:44-60
    1. Kuo CS, Munakata K, Reddy CP, Surawicz B. Characteristics and possible mechanism of ventricular arrhythmia dependent on the dispersion of action potential durations. Circulation. 1983;67:1356-1367
    1. Clayton RH, Taggart P. Regional differences in APD restitution can initiate wavebreak and re-entry in cardiac tissue: a computational study. Biomed Eng Online. 2005;4:54.
    1. Fossa AA, Wisialowski T, Crimin K. QT prolongation modifies dynamic restitution and hysteresis of the beat-to-beat QT-TQ interval relationship during normal sinus rhythm under varying states of repolarization. J Pharmacol Exp Ther. 2006;316:498-506
    1. Jiang H, Zhao D, Cui B, Lu Z, Lü J, Chen F, Bao M. Electrical restitution determined by epicardial contact mapping and surface electrocardiogram: its role in ventricular fibrillation inducibility in swine. J Electrocardiol. 2008;41:152-159
    1. Schuleri KH, Centola M, George RT, Amado LC, Evers KS, Kitagawa K, Vavere AL, Evers R, Hare JM, Cox C, McVeigh ER, Lima JAC, Lardo AC. Characterization of peri-infarct zone heterogeneity by contrast-enhanced multidetector computed tomography: a comparison with magnetic resonance imaging. J Am Coll Cardiol. 2009;53:1699-1707
    1. Yan AT, Shayne AJ, Brown KA, Gupta SN, Chan CW, Luu TM, Di Carli MF, Reynolds HG, Stevenson WG, Kwong RY. Characterization of the peri-infarct zone by contrast-enhanced cardiac magnetic resonance imaging is a powerful predictor of post-myocardial infarction mortality. Circulation. 2006;114:32-39
    1. Schmidt A, Azevedo CF, Cheng A, Gupta SN, Bluemke DA, Foo TK, Gerstenblith G, Weiss RG, Marban E, Tomaselli GF, Lima JAC, Wu KC. Infarct tissue heterogeneity by magnetic resonance imaging identifies enhanced cardiac arrhythmia susceptibility in patients with left ventricular dysfunction. Circulation. 2007;115:2006-2014
    1. National Institute for Health and Clinical Excellence. January 2006. Implantable cardioverter defibrillators for arrhythmias Review of Technology Appraisal 11. TA95. London: National Institute for Health and Clinical Excellence. Available from: .
    1. Zehender M, Brugada P, Geibel A, Waldecker B, Stevenson W, Wellens HJJ. Programmed electrical stimulation in healed myocardial infarction using a standardized ventricular stimulation protocol. Am J Cardiol. 1987;59:578-585
    1. Murray A, McLaughlin NB, Bourke JP, Doig JC, Furniss SS, Campbell RW. Errors in manual measurement of QT intervals. Br Heart J. 1994;71:386-390
    1. Taggart P, Sutton P, Chalabi Z, Boyett MR, Simon R, Elliott D, Gill JS. Effect of adrenergic stimulation on action potential duration restitution in humans. Circulation. 2003;107:285-289
    1. Panikkath R, Reinier K, Uy-Evanado A, Teodorescu C, Hattenhauer J, Mariani R, Gunson K, Jui J, Chugh SS. Prolonged Tpeak-to-Tend interval on the resting ECG is associated with increased risk of sudden cardiac death. Circ Arrhythm Electrophysiol. 2011;4:441-447
    1. Day CP, McComb JM, Campbell RW. QT dispersion: an indication of arrhythmia risk in patients with long QT intervals. Br Heart J. 1990;63:342-344
    1. Petersen SE, Jung BA, Wiesmann F, Selvanayagam JB, Francis JM, Hennig J, Neubauer S, Robson MD. Myocardial tissue phase mapping with cine phase-contrast MR imaging: regional wall motion analysis in healthy volunteers. Radiology. 2006;238:816-826
    1. Simonetti OP, Kim RJ, Fieno DS, Hillenbrand HB, Wu E, Bundy JM, Finn JP, Judd RM. An improved MR imaging technique for the visualization of myocardial infarction. Radiology. 2001;218:215-223
    1. Selvanayagam JB, Kardos A, Francis JM, Wiesmann F, Petersen SE, Taggart DP, Neubauer S. Value of delayed-enhancement cardiovascular magnetic resonance imaging in predicting myocardial viability after surgical revascularization. Circulation. 2004;110:1535-1541
    1. Gold MR, Ip JH, Costantini O, Poole JE, McNulty S, Mark DB, Lee KL, Bardy GH. Role of microvolt T-wave alternans in assessment of arrhythmia vulnerability among patients with heart failure and systolic dysfunction: primary results from the T-wave alternans sudden cardiac death in heart failure trial substudy. Circulation. 2008;118:2022-2028
    1. Bigger JT. Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary-artery bypass graft surgery. N Engl J Med. 1997;337:1569-1575
    1. Ng GA, Mantravadi R, Walker WH, Ortin WG, Choi BR, de Groat W, Salama G. Sympathetic nerve stimulation produces spatial heterogeneities of action potential restitution. Heart Rhythm. 2009;6:696-706
    1. Chen PS, Garfinkel A, Weiss JN, Karagueuzian HS. Spirals, chaos, and new mechanisms of wave propagation. PACE. 1997;20:414-421
    1. Ng GA, Brack KE, Patel VH, Coote JH. Autonomic modulation of electrical restitution, alternans and ventricular fibrillation initiation in the isolated heart. Cardiovasc Res. 2007;73:750-760
    1. Yue AM, Franz MR, Roberts PR, Morgan JM. Global endocardial electrical restitution in human right and left ventricles determined by noncontact mapping. J Am Coll Cardiol. 2005;46:1067-1075
    1. Nash MP, Bradley CP, Paterson DJ. Imaging electrocardiographic dispersion of depolarization and repolarization during ischemia: simultaneous body surface and epicardial mapping. Circulation. 2003;107:2257-2263
    1. Derksen R, van Rijen HVM, Wilders R, Tasseron S, Hauer RNW, Rutten WLC, de Bakker JMT. Tissue discontinuities affect conduction velocity restitution: a mechanism by which structural barriers may promote wave break. Circulation. 2003;108:882-888
    1. Cao J-M, Qu Z, Kim Y-H, Wu T-J, Garfinkel A, Weiss JN, Karagueuzian HS, Chen P-S. Spatiotemporal heterogeneity in the induction of ventricular fibrillation by rapid pacing? Importance of cardiac restitution properties. Circ Res. 1999;84:1318-1331
    1. Dilly SG, Lab MJ. Electrophysiological alternans and restitution during acute regional ischaemia in myocardium of anaesthetized pig. J Physiol. 1988;402:315-333
    1. Zhou S, Chen LS, Miyauchi Y, Miyauchi M, Kar S, Kangavari S, Fishbein MC, Sharifi B, Chen P-S. Mechanisms of cardiac nerve sprouting after myocardial infarction in dogs. Circ Res. 2004;95:76-83
    1. Gilmour RF, Jr, Gelzer AR, Otani NF. Cardiac electrical dynamics: maximizing dynamical heterogeneity. J Electrocardiol. 2007;40:S51-S55
    1. Watanabe MA, Fenton FH, Evans SJ, Hastings HM, Karma A. Mechanisms for discordant alternans. J Cardiovasc Electrophysiol. 2001;12:196-206
    1. Antzelevitch C, Shimizu W, Yan GX, Sicouri S, Weissenburger J, Nesterenko VV, Burashnikov A, Di Diego J, Saffitz J, Thomas GP. The M cell: its contribution to the ECG and to normal and abnormal electrical function of the heart. J Cardiovasc Electr. 1999;10:1124-1152
    1. Opthof T, Coronel R, Janse MJ. Is there a significant transmural gradient in repolarization time in the intact heart? Repolarization gradients in the intact heart. Circ Arrhythm Electrophysiol. 2009;2:89-96
    1. Sundqvist K, Sylvén C. Cardiac repolarization properties during standardized exercise test as studied by QT, QT peak and terminated T-wave intervals. Clin Physiol. 1989;9:419-425
    1. Haapalahti P, Viitasalo M, Perhonen M, Mäkijärvi M, Väänänen H, Oikarinen L, Hekkala A-M, Salorinne Y, Swan H, Toivonen L. Ventricular repolarization and heart rate responses during cardiovascular autonomic function testing in LQT1 subtype of long QT syndrome. Pacing Clin Electrophysiol. 2006;29:1122-1129
    1. Haapalahti P, Viitasalo M, Perhonen M, Väänänen H, Mäkijärvi M, Swan H, Toivonen L. Comparison of QT peak and QT end interval responses to autonomic adaptation in asymptomatic LQT1 mutation carriers. Clin Physiol Funct Imaging. 2011;31:209-214
    1. Amado LC, Gerber BL, Gupta SN, Rettmann DW, Szarf G, Schock R, Nasir K, Kraitchman DL, Lima JAC. Accurate and objective infarct sizing by contrast-enhanced magnetic resonance imaging in a canine myocardial infarction model. J Am Coll Cardiol. 2004;44:2383-2389
    1. Codreanu A, Odille F, Aliot E, Marie P-Y, Magnin-Poull I, Andronache M, Mandry D, Djaballah W, Regent D, Felblinger J, de Chillou C. Electroanatomic characterization of post-infarct scars: comparison with 3-dimensional myocardial scar reconstruction based on magnetic resonance imaging. J Am Coll Cardiol. 2008;52:839-842
    1. Hu Q, Wang X, Lee J, Mansoor A, Liu J, Zeng L, Swingen C, Zhang G, Feygin J, Ochiai K, Bransford TL, From AH, Bache RJ, Zhang J. Profound bioenergetic abnormalities in peri-infarct myocardial regions. Am J Physiol Heart Circ Physiol. 2006;291:H648-H657
    1. Malik M, Batchvarov VN. Measurement, interpretation and clinical potential of QT dispersion. J Am Coll Cardiol. 2000;36:1749-1766

Source: PubMed