Discontinuation of proton pump inhibitor use reduces the number of endoscopic procedures required for resolution of walled-off pancreatic necrosis

Patrick C Powers, Ali Siddiqui, Reem Z Sharaiha, Grace Yang, Enad Dawod, Aleksey A Novikov, Amy Javia, Cynthia Edirisuriya, Arish Noor, Tayebah Mumtaz, Usama Iqbal, David E Loren, Thomas E Kowalski, Natalie Cosgrove, Yordano Alicea, Amy Tyberg, Iman Andalib, Michel Kahaleh, Douglas G Adler, Patrick C Powers, Ali Siddiqui, Reem Z Sharaiha, Grace Yang, Enad Dawod, Aleksey A Novikov, Amy Javia, Cynthia Edirisuriya, Arish Noor, Tayebah Mumtaz, Usama Iqbal, David E Loren, Thomas E Kowalski, Natalie Cosgrove, Yordano Alicea, Amy Tyberg, Iman Andalib, Michel Kahaleh, Douglas G Adler

Abstract

Background and objectives: Endoscopic drainage/debridement of symptomatic walled off necrosis (WON) using lumen-apposing metal stents (LAMS) is both safe and effective. While endoscopic management of WON is the standard approach to treatment, the ideal concomitant medical therapy remains unclear. The purpose of this study was to further elucidate the effect of proton pump inhibitor (PPIs) therapy on the technical and clinical success of endoscopic treatment of WON.

Methods: Two hundred and seventy-two patients in 8 centers with WON managed by endoscopic drainage using LAMS were evaluated. Patients were followed for at least 6 months following treatment. The patients were divided into two groups: Those that used PPIs continuously during the therapy and those not on PPIs continuously during the interval of therapy. Outcomes included but were not limited to technical success, clinical success, number of procedures performed, and adverse events.

Results: From 2013 to 2016, 272 patients underwent WON drainage with successful transmural LAMS placement. The two groups were split evenly into PPI users and non-PPI users, and matched in regards to demographics, etiology of pancreatitis, WON size, and location. There was no difference in the technical success between the two groups (100% vs. 98.8%, P = 1), or in clinical success rates (78.7% vs. 77.9%). There was a significant difference in the required number of direct endoscopic necrosectomies to achieve clinical success in the PPI vs. non-PPI group (3.2 vs. 4.6 respectively, P < 0.01). There were significantly more cases of stent occlusion in the non-PPI group vs. PPI group (9.5% vs. 20.1% P = 0.012), but all other documented adverse events were not significantly different.

Conclusion: Discontinuing PPIs during endoscopic drainage and necrosectomy of symptomatic WON appears to reduce the number of endoscopic procedures required to achieve resolution. Continuous PPI results in higher rates of early stent occlusion.

Keywords: Direct endoscopic necrosectomy; EUS; lumen-apposing metal stent; proton pump inhibitor; walled-off necrosis.

Conflict of interest statement

None

References

    1. Varadarajulu S, Bang JY, Sutton BS, et al. Equal efficacy of endoscopic and surgical cystogastrostomy for pancreatic pseudocyst drainage in a randomized trial. Gastroenterology. 2013;145:583–900.
    1. Adler DG. Surgery versus endoscopy for patients with infected pancreatic necrosis. Lancet. 2018;391:6–8.
    1. Gardner TB, Coelho-Prabhu N, Gordon SR, et al. Direct endoscopic necrosectomy for the treatment of walled-off pancreatic necrosis: Results from a multicenter U.S. Series. Gastrointest Endosc. 2011;73:718–26.
    1. Gornals JB, De la Serna-Higuera C, Sánchez-Yague A, et al. Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surg Endosc. 2013;27:1428–34.
    1. Banks PA, Bollen TL, Dervenis C, et al. Classification of acute pancreatitis–2012: Revision of the Atlanta classification and definitions by international consensus. Gut. 2013;62:102–11.
    1. Binmoeller KF, Shah J. A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections. Endoscopy. 2011;43:337–42.
    1. Itoi T, Nageshwar Reddy D, Yasuda I. New fully-covered self-expandable metal stent for endoscopic ultrasonography-guided intervention in infectious walled-off pancreatic necrosis (with video) J Hepatobiliary Pancreat Sci. 2013;20:403–6.
    1. Khreiss M, Zenati M, Clifford A, et al. Cyst gastrostomy and necrosectomy for the management of sterile walled-off pancreatic necrosis: A comparison of minimally invasive surgical and endoscopic outcomes at a high-volume pancreatic center. J Gastrointest Surg. 2015;19:1441–8.
    1. Baron TH, Harewood GC, Morgan DE, et al. Outcome differences after endoscopic drainage of pancreatic necrosis, acute pancreatic pseudocysts, and chronic pancreatic pseudocysts. Gastrointest Endosc. 2002;56:7–17.
    1. Bakker OJ, van Santvoort HC, van Brunschot S, et al. Endoscopic transgastric vs. surgical necrosectomy for infected necrotizing pancreatitis: A randomized trial. JAMA. 2012;307:1053–61.
    1. Rasch S, Phillip V, Reichel S, et al. Open surgical versus minimal invasive necrosectomy of the pancreas – A retrospective multicenter analysis of the German pancreatitis study group. PLoS One. 2016;11:e0163651.
    1. van Brunschot S, van Grinsven J, van Santvoort HC, et al. Endoscopic or surgical step-up approach for infected necrotising pancreatitis: A multicentre randomised trial. Lancet. 2018;391:51–8.
    1. Jeffrey SB, Adler DG. Lumen apposing metal stents: A review of current uses and outcomes. Gastrointest Interv. 2017;6:9–14.
    1. Bang JY, Hasan MK, Navaneethan U, et al. Lumen-apposing metal stents for drainage of pancreatic fluid collections: When and for whom? Dig Endosc. 2017;29:83–90.
    1. Shah RJ, Shah JN, Waxman I, et al. Safety and efficacy of endoscopic ultrasound-guided drainage of pancreatic fluid collections with lumen-apposing covered self-expanding metal stents. Clin Gastroenterol Hepatol. 2015;13:747–52.
    1. Walter D, Will U, Sanchez-Yague A, et al. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: A prospective cohort study. Endoscopy. 2015;47:63–7.
    1. Siddiqui AA, Adler DG, Nieto J, et al. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: A large retrospective, multicenter U.S. Experience (with videos) Gastrointest Endosc. 2016;83:699–707.
    1. Sharaiha RZ, Tyberg A, Khashab MA, et al. Endoscopic therapy with lumen-apposing metal stents is safe and effective for patients with pancreatic walled-off necrosis. Clin Gastroenterol Hepatol. 2016;14:1797–803.
    1. Rinninella E, Kunda R, Dollhopf M, et al. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: A large retrospective study (with video) Gastrointest Endosc. 2015;82:1039–46.

Source: PubMed

3
購読する