A Prospective Study to Evaluate the Performance and Acceptability of the iDesign Advanced WaveScan Study(tm) System
The results of this trial will demonstrate that the iDesign System performs as intended and is acceptable in a clinical setting.
연구 개요
상세 설명
LASIK treatment across the range of myopia with or without astigmatism, hyperopia with or without astigmatism, and mixed astigmatism.
연구 유형
중재적
등록 (실제)
77
단계
- 해당 없음
연락처 및 위치
이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.
연구 장소
-
-
British Columbia
-
Victoria, British Columbia, 캐나다, V8X 1X2
- Clearly LASIK
-
-
Manitoba
-
Winnipeg, Manitoba, 캐나다, R3C 3J5
- Image Plus Laser Eye Center
-
-
Ontario
-
Ottawa, Ontario, 캐나다, K1H 8L6
- University of Ottawa Eye Institute, The Ottawa Hospital
-
Toronto, Ontario, 캐나다, M4P 2E5
- Yonge-Eglington Laser
-
-
참여기준
연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.
자격 기준
공부할 수 있는 나이
18년 이상 (성인, 고령자)
건강한 자원 봉사자를 받아들입니다
아니
연구 대상 성별
모두
설명
Inclusion Criteria:
- Male or female, of any race, and at least 18 years old at the time the consent form is signed.
- The refractive error, based on manifest refraction (adjusted for optical infinity), must be MRSE up to -15.00 D with manifest cylinder between 0.00 and -6.00 D; MRSE up to +9.00 D with cylinder between 0.00 and +6.00 D; or manifest cylinder (from 1.00 to 6.00 D) greater than the magnitude of sphere, and the cylinder and sphere have opposite signs.
- BSCVA of 20/20 or better.
UCVA:
- Myopes must be 20/40 or worse.
- Subjects with Hyperopia or mixed astigmatism, treatment may be based on difficulty maintaining UCVA of 20/40 evidenced by spectacle/contact lens dependence for distance, as documented by the investigator.
- Wavefront diameter ≥ 4.0 mm.
- Sufficient agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction (sphere, cylinder, and axis) to allow treatment selection and generation of an ablation profile as determined by the investigational iDesign System software.
- Manifest refraction sphere within ± 0.75 D of cycloplegic refraction sphere.
- Anticipated post-operative stromal bed thickness of at least 250 microns, based on pre-operative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign System) and the intended flap thickness.
- Anticipated post-operative keratometry value (based on pre-operative iDesign System refraction and keratometry) that is appropriate.
- A stable refractive error (based on a previous exam, medical records, or prescription) as compared to the unadjusted pre-operative manifest refraction.
- Subjects who currently wear contact lenses must demonstrate refractive stability in the operative eye. Rigid or toric lenses must be removed for at least 2 weeks and SCL for at least 3 days prior to the first refraction used to establish stability. A second refraction with a change of no more than ± 0.50 D MRSE at least 7 days after baseline.
- Willing and capable of returning for follow-up examinations for the duration of the study.
Exclusion Criteria:
- Women who are pregnant, breast-feeding, or intend to become pregnant over the course of the study, as determined by verbal inquiry, or another condition associated with the fluctuation of hormones that could lead to refractive changes.
- Subjects with an ametropic or amblyopic fellow eye not meeting all inclusion criteria that does not fall within the indications for treatment using the VISX® STAR S4 IR™ Excimer Laser.
- Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: steroids, antimetabolites, isotretinoin (Accutane™) within 6 months of treatment, and amiodarone hydrochloride (Cordarone™) within 12 months of treatment.
- Acute or chronic disease, illness, or treatment that would increase the operative risk (e.g., immuno-compromised, autoimmune disease, connective tissue disease, clinically significant atopic disease, diabetes, etc.).
- Subjects with a cardiac pacemaker, implanted defibrillator, implanted neurostimulator, or any active electrical implants.
- Ocular condition (other than high myopia) that may predispose the subject to future complications, such as history or evidence of active or inactive corneal disease
- Previous intraocular or corneal surgery that might confound the outcome of the study or increase risk to the subject.
- Known sensitivity or inappropriate responsiveness to any of the medications used in the post-operative course.
- Concurrent participation in any other clinical study.
공부 계획
이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위화되지 않음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Refractive Error
|
CustomVue LASIK targeted for emmetropia
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Percentage of Eyes With Uncorrected Visual Acuity (UCVA) of 20/40 or Better.
기간: 6 months
|
6 months
|
기타 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
2줄 이상 손실된 눈의 비율 최고 안경 교정 시력(BSCVA)
기간: 6 개월
|
6 개월
|
|
|
Percentage of Eyes With Manifest Refraction Spherical Equivalent Within 1.0 D
기간: 6 months
|
6 months
|
|
|
Percentage of Eyes With Best Spectacle Corrected Visual Acuity (BSCVA) Worse Than 20/40
기간: 6 Months
|
6 Months
|
|
|
Percentage of Eyes With Induced Manifest Refractive Astigmatism Greater Than 2.00 D of Absolute Cylinder as Compared to the Preoperative Refraction
기간: 6 Months
|
Induced Manifest Refractive Astigmatism is an increase of astigmatism (cylinder) postoperatively that could be caused by the refractive treatment.
An increase of greater than 2.0 D is considered a safety endpoint per ANSI Z80.11-2007.
|
6 Months
|
공동 작업자 및 조사자
여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.
연구 기록 날짜
이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.
연구 주요 날짜
연구 시작
2010년 10월 1일
기본 완료 (실제)
2011년 6월 1일
연구 완료 (실제)
2011년 12월 1일
연구 등록 날짜
최초 제출
2010년 9월 24일
QC 기준을 충족하는 최초 제출
2010년 10월 12일
처음 게시됨 (추정)
2010년 10월 14일
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
2013년 5월 20일
QC 기준을 충족하는 마지막 업데이트 제출
2013년 5월 16일
마지막으로 확인됨
2013년 5월 1일
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .