Performance and Acceptability of iDesign
16. května 2013 aktualizováno: Abbott Medical Optics
A Prospective Study to Evaluate the Performance and Acceptability of the iDesign Advanced WaveScan Study(tm) System
The results of this trial will demonstrate that the iDesign System performs as intended and is acceptable in a clinical setting.
Přehled studie
Postavení
Dokončeno
Podmínky
Intervence / Léčba
Detailní popis
LASIK treatment across the range of myopia with or without astigmatism, hyperopia with or without astigmatism, and mixed astigmatism.
Typ studie
Intervenční
Zápis (Aktuální)
77
Fáze
- Nelze použít
Kontakty a umístění
Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.
Studijní místa
-
-
British Columbia
-
Victoria, British Columbia, Kanada, V8X 1X2
- Clearly LASIK
-
-
Manitoba
-
Winnipeg, Manitoba, Kanada, R3C 3J5
- Image Plus Laser Eye Center
-
-
Ontario
-
Ottawa, Ontario, Kanada, K1H 8L6
- University of Ottawa Eye Institute, The Ottawa Hospital
-
Toronto, Ontario, Kanada, M4P 2E5
- Yonge-Eglington Laser
-
-
Kritéria účasti
Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.
Kritéria způsobilosti
Věk způsobilý ke studiu
18 let a starší (Dospělý, Starší dospělý)
Přijímá zdravé dobrovolníky
Ne
Pohlaví způsobilá ke studiu
Všechno
Popis
Inclusion Criteria:
- Male or female, of any race, and at least 18 years old at the time the consent form is signed.
- The refractive error, based on manifest refraction (adjusted for optical infinity), must be MRSE up to -15.00 D with manifest cylinder between 0.00 and -6.00 D; MRSE up to +9.00 D with cylinder between 0.00 and +6.00 D; or manifest cylinder (from 1.00 to 6.00 D) greater than the magnitude of sphere, and the cylinder and sphere have opposite signs.
- BSCVA of 20/20 or better.
UCVA:
- Myopes must be 20/40 or worse.
- Subjects with Hyperopia or mixed astigmatism, treatment may be based on difficulty maintaining UCVA of 20/40 evidenced by spectacle/contact lens dependence for distance, as documented by the investigator.
- Wavefront diameter ≥ 4.0 mm.
- Sufficient agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction (sphere, cylinder, and axis) to allow treatment selection and generation of an ablation profile as determined by the investigational iDesign System software.
- Manifest refraction sphere within ± 0.75 D of cycloplegic refraction sphere.
- Anticipated post-operative stromal bed thickness of at least 250 microns, based on pre-operative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign System) and the intended flap thickness.
- Anticipated post-operative keratometry value (based on pre-operative iDesign System refraction and keratometry) that is appropriate.
- A stable refractive error (based on a previous exam, medical records, or prescription) as compared to the unadjusted pre-operative manifest refraction.
- Subjects who currently wear contact lenses must demonstrate refractive stability in the operative eye. Rigid or toric lenses must be removed for at least 2 weeks and SCL for at least 3 days prior to the first refraction used to establish stability. A second refraction with a change of no more than ± 0.50 D MRSE at least 7 days after baseline.
- Willing and capable of returning for follow-up examinations for the duration of the study.
Exclusion Criteria:
- Women who are pregnant, breast-feeding, or intend to become pregnant over the course of the study, as determined by verbal inquiry, or another condition associated with the fluctuation of hormones that could lead to refractive changes.
- Subjects with an ametropic or amblyopic fellow eye not meeting all inclusion criteria that does not fall within the indications for treatment using the VISX® STAR S4 IR™ Excimer Laser.
- Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: steroids, antimetabolites, isotretinoin (Accutane™) within 6 months of treatment, and amiodarone hydrochloride (Cordarone™) within 12 months of treatment.
- Acute or chronic disease, illness, or treatment that would increase the operative risk (e.g., immuno-compromised, autoimmune disease, connective tissue disease, clinically significant atopic disease, diabetes, etc.).
- Subjects with a cardiac pacemaker, implanted defibrillator, implanted neurostimulator, or any active electrical implants.
- Ocular condition (other than high myopia) that may predispose the subject to future complications, such as history or evidence of active or inactive corneal disease
- Previous intraocular or corneal surgery that might confound the outcome of the study or increase risk to the subject.
- Known sensitivity or inappropriate responsiveness to any of the medications used in the post-operative course.
- Concurrent participation in any other clinical study.
Studijní plán
Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Nerandomizované
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Refractive Error
|
CustomVue LASIK targeted for emmetropia
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
Percentage of Eyes With Uncorrected Visual Acuity (UCVA) of 20/40 or Better.
Časové okno: 6 months
|
6 months
|
Další výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Procento očí se ztrátou více než 2 řádků Nejlepší zraková ostrost korigovaná brýlemi (BSCVA)
Časové okno: 6 měsíců
|
6 měsíců
|
|
|
Percentage of Eyes With Manifest Refraction Spherical Equivalent Within 1.0 D
Časové okno: 6 months
|
6 months
|
|
|
Percentage of Eyes With Best Spectacle Corrected Visual Acuity (BSCVA) Worse Than 20/40
Časové okno: 6 Months
|
6 Months
|
|
|
Percentage of Eyes With Induced Manifest Refractive Astigmatism Greater Than 2.00 D of Absolute Cylinder as Compared to the Preoperative Refraction
Časové okno: 6 Months
|
Induced Manifest Refractive Astigmatism is an increase of astigmatism (cylinder) postoperatively that could be caused by the refractive treatment.
An increase of greater than 2.0 D is considered a safety endpoint per ANSI Z80.11-2007.
|
6 Months
|
Spolupracovníci a vyšetřovatelé
Zde najdete lidi a organizace zapojené do této studie.
Sponzor
Termíny studijních záznamů
Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.
Hlavní termíny studia
Začátek studia
1. října 2010
Primární dokončení (Aktuální)
1. června 2011
Dokončení studie (Aktuální)
1. prosince 2011
Termíny zápisu do studia
První předloženo
24. září 2010
První předloženo, které splnilo kritéria kontroly kvality
12. října 2010
První zveřejněno (Odhad)
14. října 2010
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
20. května 2013
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
16. května 2013
Naposledy ověřeno
1. května 2013
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- STAR-108-IDSN
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .