Performance and Acceptability of iDesign

16 de mayo de 2013 actualizado por: Abbott Medical Optics

A Prospective Study to Evaluate the Performance and Acceptability of the iDesign Advanced WaveScan Study(tm) System

The results of this trial will demonstrate that the iDesign System performs as intended and is acceptable in a clinical setting.

Descripción general del estudio

Estado

Terminado

Condiciones

Descripción detallada

LASIK treatment across the range of myopia with or without astigmatism, hyperopia with or without astigmatism, and mixed astigmatism.

Tipo de estudio

Intervencionista

Inscripción (Actual)

77

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • British Columbia
      • Victoria, British Columbia, Canadá, V8X 1X2
        • Clearly LASIK
    • Manitoba
      • Winnipeg, Manitoba, Canadá, R3C 3J5
        • Image Plus Laser Eye Center
    • Ontario
      • Ottawa, Ontario, Canadá, K1H 8L6
        • University of Ottawa Eye Institute, The Ottawa Hospital
      • Toronto, Ontario, Canadá, M4P 2E5
        • Yonge-Eglington Laser

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Male or female, of any race, and at least 18 years old at the time the consent form is signed.
  • The refractive error, based on manifest refraction (adjusted for optical infinity), must be MRSE up to -15.00 D with manifest cylinder between 0.00 and -6.00 D; MRSE up to +9.00 D with cylinder between 0.00 and +6.00 D; or manifest cylinder (from 1.00 to 6.00 D) greater than the magnitude of sphere, and the cylinder and sphere have opposite signs.
  • BSCVA of 20/20 or better.
  • UCVA:

    • Myopes must be 20/40 or worse.
    • Subjects with Hyperopia or mixed astigmatism, treatment may be based on difficulty maintaining UCVA of 20/40 evidenced by spectacle/contact lens dependence for distance, as documented by the investigator.
  • Wavefront diameter ≥ 4.0 mm.
  • Sufficient agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction (sphere, cylinder, and axis) to allow treatment selection and generation of an ablation profile as determined by the investigational iDesign System software.
  • Manifest refraction sphere within ± 0.75 D of cycloplegic refraction sphere.
  • Anticipated post-operative stromal bed thickness of at least 250 microns, based on pre-operative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign System) and the intended flap thickness.
  • Anticipated post-operative keratometry value (based on pre-operative iDesign System refraction and keratometry) that is appropriate.
  • A stable refractive error (based on a previous exam, medical records, or prescription) as compared to the unadjusted pre-operative manifest refraction.
  • Subjects who currently wear contact lenses must demonstrate refractive stability in the operative eye. Rigid or toric lenses must be removed for at least 2 weeks and SCL for at least 3 days prior to the first refraction used to establish stability. A second refraction with a change of no more than ± 0.50 D MRSE at least 7 days after baseline.
  • Willing and capable of returning for follow-up examinations for the duration of the study.

Exclusion Criteria:

  • Women who are pregnant, breast-feeding, or intend to become pregnant over the course of the study, as determined by verbal inquiry, or another condition associated with the fluctuation of hormones that could lead to refractive changes.
  • Subjects with an ametropic or amblyopic fellow eye not meeting all inclusion criteria that does not fall within the indications for treatment using the VISX® STAR S4 IR™ Excimer Laser.
  • Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: steroids, antimetabolites, isotretinoin (Accutane™) within 6 months of treatment, and amiodarone hydrochloride (Cordarone™) within 12 months of treatment.
  • Acute or chronic disease, illness, or treatment that would increase the operative risk (e.g., immuno-compromised, autoimmune disease, connective tissue disease, clinically significant atopic disease, diabetes, etc.).
  • Subjects with a cardiac pacemaker, implanted defibrillator, implanted neurostimulator, or any active electrical implants.
  • Ocular condition (other than high myopia) that may predispose the subject to future complications, such as history or evidence of active or inactive corneal disease
  • Previous intraocular or corneal surgery that might confound the outcome of the study or increase risk to the subject.
  • Known sensitivity or inappropriate responsiveness to any of the medications used in the post-operative course.
  • Concurrent participation in any other clinical study.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: No aleatorizado
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Refractive Error
CustomVue LASIK targeted for emmetropia
Otros nombres:
  • CustomVue

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
Percentage of Eyes With Uncorrected Visual Acuity (UCVA) of 20/40 or Better.
Periodo de tiempo: 6 months
6 months

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Porcentaje de ojos con pérdida de más de 2 líneas Mejor agudeza visual corregida con anteojos (BSCVA)
Periodo de tiempo: 6 meses
6 meses
Percentage of Eyes With Manifest Refraction Spherical Equivalent Within 1.0 D
Periodo de tiempo: 6 months
6 months
Percentage of Eyes With Best Spectacle Corrected Visual Acuity (BSCVA) Worse Than 20/40
Periodo de tiempo: 6 Months
6 Months
Percentage of Eyes With Induced Manifest Refractive Astigmatism Greater Than 2.00 D of Absolute Cylinder as Compared to the Preoperative Refraction
Periodo de tiempo: 6 Months
Induced Manifest Refractive Astigmatism is an increase of astigmatism (cylinder) postoperatively that could be caused by the refractive treatment. An increase of greater than 2.0 D is considered a safety endpoint per ANSI Z80.11-2007.
6 Months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de octubre de 2010

Finalización primaria (Actual)

1 de junio de 2011

Finalización del estudio (Actual)

1 de diciembre de 2011

Fechas de registro del estudio

Enviado por primera vez

24 de septiembre de 2010

Primero enviado que cumplió con los criterios de control de calidad

12 de octubre de 2010

Publicado por primera vez (Estimar)

14 de octubre de 2010

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

20 de mayo de 2013

Última actualización enviada que cumplió con los criterios de control de calidad

16 de mayo de 2013

Última verificación

1 de mayo de 2013

Más información

Términos relacionados con este estudio

Términos MeSH relevantes adicionales

Otros números de identificación del estudio

  • STAR-108-IDSN

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .