Performance and Acceptability of iDesign

16 mai 2013 mis à jour par: Abbott Medical Optics

A Prospective Study to Evaluate the Performance and Acceptability of the iDesign Advanced WaveScan Study(tm) System

The results of this trial will demonstrate that the iDesign System performs as intended and is acceptable in a clinical setting.

Aperçu de l'étude

Statut

Complété

Les conditions

Description détaillée

LASIK treatment across the range of myopia with or without astigmatism, hyperopia with or without astigmatism, and mixed astigmatism.

Type d'étude

Interventionnel

Inscription (Réel)

77

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • British Columbia
      • Victoria, British Columbia, Canada, V8X 1X2
        • Clearly LASIK
    • Manitoba
      • Winnipeg, Manitoba, Canada, R3C 3J5
        • Image Plus Laser Eye Center
    • Ontario
      • Ottawa, Ontario, Canada, K1H 8L6
        • University of Ottawa Eye Institute, The Ottawa Hospital
      • Toronto, Ontario, Canada, M4P 2E5
        • Yonge-Eglington Laser

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Male or female, of any race, and at least 18 years old at the time the consent form is signed.
  • The refractive error, based on manifest refraction (adjusted for optical infinity), must be MRSE up to -15.00 D with manifest cylinder between 0.00 and -6.00 D; MRSE up to +9.00 D with cylinder between 0.00 and +6.00 D; or manifest cylinder (from 1.00 to 6.00 D) greater than the magnitude of sphere, and the cylinder and sphere have opposite signs.
  • BSCVA of 20/20 or better.
  • UCVA:

    • Myopes must be 20/40 or worse.
    • Subjects with Hyperopia or mixed astigmatism, treatment may be based on difficulty maintaining UCVA of 20/40 evidenced by spectacle/contact lens dependence for distance, as documented by the investigator.
  • Wavefront diameter ≥ 4.0 mm.
  • Sufficient agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction (sphere, cylinder, and axis) to allow treatment selection and generation of an ablation profile as determined by the investigational iDesign System software.
  • Manifest refraction sphere within ± 0.75 D of cycloplegic refraction sphere.
  • Anticipated post-operative stromal bed thickness of at least 250 microns, based on pre-operative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign System) and the intended flap thickness.
  • Anticipated post-operative keratometry value (based on pre-operative iDesign System refraction and keratometry) that is appropriate.
  • A stable refractive error (based on a previous exam, medical records, or prescription) as compared to the unadjusted pre-operative manifest refraction.
  • Subjects who currently wear contact lenses must demonstrate refractive stability in the operative eye. Rigid or toric lenses must be removed for at least 2 weeks and SCL for at least 3 days prior to the first refraction used to establish stability. A second refraction with a change of no more than ± 0.50 D MRSE at least 7 days after baseline.
  • Willing and capable of returning for follow-up examinations for the duration of the study.

Exclusion Criteria:

  • Women who are pregnant, breast-feeding, or intend to become pregnant over the course of the study, as determined by verbal inquiry, or another condition associated with the fluctuation of hormones that could lead to refractive changes.
  • Subjects with an ametropic or amblyopic fellow eye not meeting all inclusion criteria that does not fall within the indications for treatment using the VISX® STAR S4 IR™ Excimer Laser.
  • Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: steroids, antimetabolites, isotretinoin (Accutane™) within 6 months of treatment, and amiodarone hydrochloride (Cordarone™) within 12 months of treatment.
  • Acute or chronic disease, illness, or treatment that would increase the operative risk (e.g., immuno-compromised, autoimmune disease, connective tissue disease, clinically significant atopic disease, diabetes, etc.).
  • Subjects with a cardiac pacemaker, implanted defibrillator, implanted neurostimulator, or any active electrical implants.
  • Ocular condition (other than high myopia) that may predispose the subject to future complications, such as history or evidence of active or inactive corneal disease
  • Previous intraocular or corneal surgery that might confound the outcome of the study or increase risk to the subject.
  • Known sensitivity or inappropriate responsiveness to any of the medications used in the post-operative course.
  • Concurrent participation in any other clinical study.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Refractive Error
CustomVue LASIK targeted for emmetropia
Autres noms:
  • CustomVue

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Délai
Percentage of Eyes With Uncorrected Visual Acuity (UCVA) of 20/40 or Better.
Délai: 6 months
6 months

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Pourcentage d'yeux avec une perte de plus de 2 lignes Meilleure acuité visuelle corrigée par les lunettes (BSCVA)
Délai: 6 mois
6 mois
Percentage of Eyes With Manifest Refraction Spherical Equivalent Within 1.0 D
Délai: 6 months
6 months
Percentage of Eyes With Best Spectacle Corrected Visual Acuity (BSCVA) Worse Than 20/40
Délai: 6 Months
6 Months
Percentage of Eyes With Induced Manifest Refractive Astigmatism Greater Than 2.00 D of Absolute Cylinder as Compared to the Preoperative Refraction
Délai: 6 Months
Induced Manifest Refractive Astigmatism is an increase of astigmatism (cylinder) postoperatively that could be caused by the refractive treatment. An increase of greater than 2.0 D is considered a safety endpoint per ANSI Z80.11-2007.
6 Months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 octobre 2010

Achèvement primaire (Réel)

1 juin 2011

Achèvement de l'étude (Réel)

1 décembre 2011

Dates d'inscription aux études

Première soumission

24 septembre 2010

Première soumission répondant aux critères de contrôle qualité

12 octobre 2010

Première publication (Estimation)

14 octobre 2010

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

20 mai 2013

Dernière mise à jour soumise répondant aux critères de contrôle qualité

16 mai 2013

Dernière vérification

1 mai 2013

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • STAR-108-IDSN

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur STAR S4IR LASIK with iDesign Aberrometer