Performance and Acceptability of iDesign

16 maggio 2013 aggiornato da: Abbott Medical Optics

A Prospective Study to Evaluate the Performance and Acceptability of the iDesign Advanced WaveScan Study(tm) System

The results of this trial will demonstrate that the iDesign System performs as intended and is acceptable in a clinical setting.

Panoramica dello studio

Stato

Completato

Descrizione dettagliata

LASIK treatment across the range of myopia with or without astigmatism, hyperopia with or without astigmatism, and mixed astigmatism.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

77

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • British Columbia
      • Victoria, British Columbia, Canada, V8X 1X2
        • Clearly LASIK
    • Manitoba
      • Winnipeg, Manitoba, Canada, R3C 3J5
        • Image Plus Laser Eye Center
    • Ontario
      • Ottawa, Ontario, Canada, K1H 8L6
        • University of Ottawa Eye Institute, The Ottawa Hospital
      • Toronto, Ontario, Canada, M4P 2E5
        • Yonge-Eglington Laser

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Male or female, of any race, and at least 18 years old at the time the consent form is signed.
  • The refractive error, based on manifest refraction (adjusted for optical infinity), must be MRSE up to -15.00 D with manifest cylinder between 0.00 and -6.00 D; MRSE up to +9.00 D with cylinder between 0.00 and +6.00 D; or manifest cylinder (from 1.00 to 6.00 D) greater than the magnitude of sphere, and the cylinder and sphere have opposite signs.
  • BSCVA of 20/20 or better.
  • UCVA:

    • Myopes must be 20/40 or worse.
    • Subjects with Hyperopia or mixed astigmatism, treatment may be based on difficulty maintaining UCVA of 20/40 evidenced by spectacle/contact lens dependence for distance, as documented by the investigator.
  • Wavefront diameter ≥ 4.0 mm.
  • Sufficient agreement between manifest refraction (adjusted for optical infinity) and iDesign System refraction (sphere, cylinder, and axis) to allow treatment selection and generation of an ablation profile as determined by the investigational iDesign System software.
  • Manifest refraction sphere within ± 0.75 D of cycloplegic refraction sphere.
  • Anticipated post-operative stromal bed thickness of at least 250 microns, based on pre-operative central corneal pachymetry minus the maximum treatment depth to be ablated (as calculated by the iDesign System) and the intended flap thickness.
  • Anticipated post-operative keratometry value (based on pre-operative iDesign System refraction and keratometry) that is appropriate.
  • A stable refractive error (based on a previous exam, medical records, or prescription) as compared to the unadjusted pre-operative manifest refraction.
  • Subjects who currently wear contact lenses must demonstrate refractive stability in the operative eye. Rigid or toric lenses must be removed for at least 2 weeks and SCL for at least 3 days prior to the first refraction used to establish stability. A second refraction with a change of no more than ± 0.50 D MRSE at least 7 days after baseline.
  • Willing and capable of returning for follow-up examinations for the duration of the study.

Exclusion Criteria:

  • Women who are pregnant, breast-feeding, or intend to become pregnant over the course of the study, as determined by verbal inquiry, or another condition associated with the fluctuation of hormones that could lead to refractive changes.
  • Subjects with an ametropic or amblyopic fellow eye not meeting all inclusion criteria that does not fall within the indications for treatment using the VISX® STAR S4 IR™ Excimer Laser.
  • Concurrent use of systemic (including inhaled) medications that may impair healing, including but not limited to: steroids, antimetabolites, isotretinoin (Accutane™) within 6 months of treatment, and amiodarone hydrochloride (Cordarone™) within 12 months of treatment.
  • Acute or chronic disease, illness, or treatment that would increase the operative risk (e.g., immuno-compromised, autoimmune disease, connective tissue disease, clinically significant atopic disease, diabetes, etc.).
  • Subjects with a cardiac pacemaker, implanted defibrillator, implanted neurostimulator, or any active electrical implants.
  • Ocular condition (other than high myopia) that may predispose the subject to future complications, such as history or evidence of active or inactive corneal disease
  • Previous intraocular or corneal surgery that might confound the outcome of the study or increase risk to the subject.
  • Known sensitivity or inappropriate responsiveness to any of the medications used in the post-operative course.
  • Concurrent participation in any other clinical study.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Non randomizzato
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Refractive Error
CustomVue LASIK targeted for emmetropia
Altri nomi:
  • CustomVue

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
Percentage of Eyes With Uncorrected Visual Acuity (UCVA) of 20/40 or Better.
Lasso di tempo: 6 months
6 months

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Percentuale di occhi con perdita di oltre 2 linee Migliore acuità visiva corretta per occhiali (BSCVA)
Lasso di tempo: 6 mesi
6 mesi
Percentage of Eyes With Manifest Refraction Spherical Equivalent Within 1.0 D
Lasso di tempo: 6 months
6 months
Percentage of Eyes With Best Spectacle Corrected Visual Acuity (BSCVA) Worse Than 20/40
Lasso di tempo: 6 Months
6 Months
Percentage of Eyes With Induced Manifest Refractive Astigmatism Greater Than 2.00 D of Absolute Cylinder as Compared to the Preoperative Refraction
Lasso di tempo: 6 Months
Induced Manifest Refractive Astigmatism is an increase of astigmatism (cylinder) postoperatively that could be caused by the refractive treatment. An increase of greater than 2.0 D is considered a safety endpoint per ANSI Z80.11-2007.
6 Months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

1 ottobre 2010

Completamento primario (Effettivo)

1 giugno 2011

Completamento dello studio (Effettivo)

1 dicembre 2011

Date di iscrizione allo studio

Primo inviato

24 settembre 2010

Primo inviato che soddisfa i criteri di controllo qualità

12 ottobre 2010

Primo Inserito (Stima)

14 ottobre 2010

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Stima)

20 maggio 2013

Ultimo aggiornamento inviato che soddisfa i criteri QC

16 maggio 2013

Ultimo verificato

1 maggio 2013

Maggiori informazioni

Termini relativi a questo studio

Termini MeSH pertinenti aggiuntivi

Altri numeri di identificazione dello studio

  • STAR-108-IDSN

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su STAR S4IR LASIK with iDesign Aberrometer