EMG-Based Hand-Wrist Control: Study B Mirrored (PSICON-B)

2020년 12월 30일 업데이트: Liberating Technologies, Inc.

EMG-Based Hand-Wrist Control: Study B: Comparison of Contralateral (Mirrored) EMG-

Study assessing four-channel prosthesis controller, that compares contralateral (mirrored) EMG-force training to ipsilateral EMG-target training with both limb-absent and able-bodied subjects

연구 개요

상세 설명

System identification models relating forearm electromyogram (EMG) signals to phantom wrist radial-ulnar deviation force, pronation-supination moment and/or hand open-close force (EMG-force) are hampered by lack of supervised force/moment output signals in limb-absent subjects. In able-bodied and unilateral transradial limb-absent subjects, we studied three alternative supervised output sources in one degree of freedom (DoF) and 2-DoF target tracking tasks: (1) bilateral tracking with force feedback from the contralateral side (non-dominant for able-bodied/ sound for limb-absent subjects) with the contralateral force as the output, (2) bilateral tracking with force feedback from the contralateral side with the target as the output, and (3) dominant/limb-absent side unilateral target tracking without feedback and the target used as the output.

연구 유형

중재적

등록 (실제)

20

단계

  • 초기 1단계

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Massachusetts
      • Holliston, Massachusetts, 미국, 01746
        • Liberating Technologies, Inc
      • Worcester, Massachusetts, 미국, 01609
        • Worcester Polytechnic Institute

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Limb-absent subjects: unilateral trans-radial limb absence or amputation
  • Be capable of completing the requested contractions on the affected dominant side

Exclusion Criteria:

  • Past injuries to the upper limbs that would limit their ability to complete the requested contractions
  • Scars that would impede the use of surface electrodes

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 기초 과학
  • 할당: 무작위화되지 않음
  • 중재 모델: 순차적 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Study B: Limb-Absent Subject
Ten unilateral transradial limb-absent subjects will each participate in one, half-day experimental session. Subjects will be seated and prepared in test apparatus seat (16 electrodes on the affected side, hand-wrist on the able side secured to load cells). Subjects will complete the 1-DoF and 2-DoF "dynamic" (force-varying) contractions (40-s duration, 0.75 Hz bandlimited, uniform random target). With 2 DoF contraction trials, hand Opn-Cls will always be one of the dimensions. The subject will then be released from the cuff and their able side not further involved in the experiment. The force feedback triangle cursor on the computer screen will be deleted such that only the target remains. Subjects will then repeat 1-DoF and 2-DoF trials in which the affected side attempts to produce hand-wrist effort that mimic movement of the target (with no feedback provided).
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)]. sEMG system used 16 custom encased bipolar electrodes. A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC. A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement. A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces. The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target. The subject controlled a second triangular cursor. Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
다른 이름들:
  • load cell
  • electrode array
실험적: Study B: Able-bodied Subjects
Ten able-bodied subjects, the electrodes will be mounted on the dominant arm for the EMG-force and EMG-target tracking trials. In addition, the non-dominant arm will also be constrained and measured in a second load cell. This load cell will not be used for feedback during the experiment, but will compare (RMS error, off-line) the dominant vs. non-dominant forces. For EMG-target tracking, the dominant hand will remain in the wrist cuff (to prevent flailing during contractions), with the screen feedback disabled. These subjects will repeat the trials with the electrodes moved to the non-dominant side. EMG-force tracking will be repeated using mirrored contractions. The three training methods (EMG-force ipsilateral, EMG-force contralateral mirrored, EMG-target on the dominant side) will be contrasted to help understand the source of errors when training with limb-absent subjects.
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)]. sEMG system used 16 custom encased bipolar electrodes. A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC. A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement. A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces. The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target. The subject controlled a second triangular cursor. Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
다른 이름들:
  • load cell
  • electrode array

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
EMG-Force Models
기간: 1 day visit

Electromyogram waveform measurements (signal amplitude, frequency) will be related to force measurements (magnitude and moment) as related to the target tracking tasks. These signal-force data will be use to generate the models.

The specific outcome for each subject will be the RMS error measured in the tracking tasks as the difference between the generated control signal from the user versus the prompted target signal, as measured by an EMG array.

1 day visit

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2017년 6월 29일

기본 완료 (실제)

2020년 8월 24일

연구 완료 (실제)

2020년 8월 24일

연구 등록 날짜

최초 제출

2020년 12월 28일

QC 기준을 충족하는 최초 제출

2020년 12월 30일

처음 게시됨 (실제)

2021년 1월 5일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2021년 1월 5일

QC 기준을 충족하는 마지막 업데이트 제출

2020년 12월 30일

마지막으로 확인됨

2020년 12월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • 124039
  • IRB-17-155 (기타 식별자: Worcester Polytechnic Institute)
  • 5R42HD076519-03 (미국 NIH 보조금/계약)

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

PSICON Measurement Apparatus에 대한 임상 시험

  • Medistim ASA
    아직 모집하지 않음
  • Columbia University
    National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK); Albert Einstein...
    모병
    비만 | 인슐린 저항성 | 당뇨병 전증 상태 | 고인슐린혈증 | 비알코올성 지방간 질환
    미국
  • Columbia University
    National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK); Albert Einstein...
    아직 모집하지 않음
    인슐린 저항성 | 당뇨병 전증 상태 | 과체중 및 비만 | 비알코올성 지방간 질환
    미국
3
구독하다