EMG-Based Hand-Wrist Control: Study B Mirrored (PSICON-B)
EMG-Based Hand-Wrist Control: Study B: Comparison of Contralateral (Mirrored) EMG-
Descripción general del estudio
Estado
Intervención / Tratamiento
Descripción detallada
Tipo de estudio
Inscripción (Actual)
Fase
- Fase temprana 1
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Massachusetts
-
Holliston, Massachusetts, Estados Unidos, 01746
- Liberating Technologies, Inc
-
Worcester, Massachusetts, Estados Unidos, 01609
- Worcester Polytechnic Institute
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Limb-absent subjects: unilateral trans-radial limb absence or amputation
- Be capable of completing the requested contractions on the affected dominant side
Exclusion Criteria:
- Past injuries to the upper limbs that would limit their ability to complete the requested contractions
- Scars that would impede the use of surface electrodes
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación Secuencial
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Study B: Limb-Absent Subject
Ten unilateral transradial limb-absent subjects will each participate in one, half-day experimental session.
Subjects will be seated and prepared in test apparatus seat (16 electrodes on the affected side, hand-wrist on the able side secured to load cells).
Subjects will complete the 1-DoF and 2-DoF "dynamic" (force-varying) contractions (40-s duration, 0.75 Hz bandlimited, uniform random target).
With 2 DoF contraction trials, hand Opn-Cls will always be one of the dimensions.
The subject will then be released from the cuff and their able side not further involved in the experiment.
The force feedback triangle cursor on the computer screen will be deleted such that only the target remains.
Subjects will then repeat 1-DoF and 2-DoF trials in which the affected side attempts to produce hand-wrist effort that mimic movement of the target (with no feedback provided).
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Otros nombres:
|
|
Experimental: Study B: Able-bodied Subjects
Ten able-bodied subjects, the electrodes will be mounted on the dominant arm for the EMG-force and EMG-target tracking trials.
In addition, the non-dominant arm will also be constrained and measured in a second load cell.
This load cell will not be used for feedback during the experiment, but will compare (RMS error, off-line) the dominant vs. non-dominant forces.
For EMG-target tracking, the dominant hand will remain in the wrist cuff (to prevent flailing during contractions), with the screen feedback disabled.
These subjects will repeat the trials with the electrodes moved to the non-dominant side.
EMG-force tracking will be repeated using mirrored contractions.
The three training methods (EMG-force ipsilateral, EMG-force contralateral mirrored, EMG-target on the dominant side) will be contrasted to help understand the source of errors when training with limb-absent subjects.
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
EMG-Force Models
Periodo de tiempo: 1 day visit
|
Electromyogram waveform measurements (signal amplitude, frequency) will be related to force measurements (magnitude and moment) as related to the target tracking tasks. These signal-force data will be use to generate the models. The specific outcome for each subject will be the RMS error measured in the tracking tasks as the difference between the generated control signal from the user versus the prompted target signal, as measured by an EMG array. |
1 day visit
|
Colaboradores e Investigadores
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 124039
- IRB-17-155 (Otro identificador: Worcester Polytechnic Institute)
- 5R42HD076519-03 (Subvención/contrato del NIH de EE. UU.)
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .