EMG-Based Hand-Wrist Control: Study B Mirrored (PSICON-B)
EMG-Based Hand-Wrist Control: Study B: Comparison of Contralateral (Mirrored) EMG-
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Studietype
Inschrijving (Werkelijk)
Fase
- Vroege fase 1
Contacten en locaties
Studie Locaties
-
-
Massachusetts
-
Holliston, Massachusetts, Verenigde Staten, 01746
- Liberating Technologies, Inc
-
Worcester, Massachusetts, Verenigde Staten, 01609
- Worcester Polytechnic Institute
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Limb-absent subjects: unilateral trans-radial limb absence or amputation
- Be capable of completing the requested contractions on the affected dominant side
Exclusion Criteria:
- Past injuries to the upper limbs that would limit their ability to complete the requested contractions
- Scars that would impede the use of surface electrodes
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Fundamentele wetenschap
- Toewijzing: Niet-gerandomiseerd
- Interventioneel model: Sequentiële toewijzing
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Study B: Limb-Absent Subject
Ten unilateral transradial limb-absent subjects will each participate in one, half-day experimental session.
Subjects will be seated and prepared in test apparatus seat (16 electrodes on the affected side, hand-wrist on the able side secured to load cells).
Subjects will complete the 1-DoF and 2-DoF "dynamic" (force-varying) contractions (40-s duration, 0.75 Hz bandlimited, uniform random target).
With 2 DoF contraction trials, hand Opn-Cls will always be one of the dimensions.
The subject will then be released from the cuff and their able side not further involved in the experiment.
The force feedback triangle cursor on the computer screen will be deleted such that only the target remains.
Subjects will then repeat 1-DoF and 2-DoF trials in which the affected side attempts to produce hand-wrist effort that mimic movement of the target (with no feedback provided).
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Andere namen:
|
|
Experimenteel: Study B: Able-bodied Subjects
Ten able-bodied subjects, the electrodes will be mounted on the dominant arm for the EMG-force and EMG-target tracking trials.
In addition, the non-dominant arm will also be constrained and measured in a second load cell.
This load cell will not be used for feedback during the experiment, but will compare (RMS error, off-line) the dominant vs. non-dominant forces.
For EMG-target tracking, the dominant hand will remain in the wrist cuff (to prevent flailing during contractions), with the screen feedback disabled.
These subjects will repeat the trials with the electrodes moved to the non-dominant side.
EMG-force tracking will be repeated using mirrored contractions.
The three training methods (EMG-force ipsilateral, EMG-force contralateral mirrored, EMG-target on the dominant side) will be contrasted to help understand the source of errors when training with limb-absent subjects.
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
EMG-Force Models
Tijdsspanne: 1 day visit
|
Electromyogram waveform measurements (signal amplitude, frequency) will be related to force measurements (magnitude and moment) as related to the target tracking tasks. These signal-force data will be use to generate the models. The specific outcome for each subject will be the RMS error measured in the tracking tasks as the difference between the generated control signal from the user versus the prompted target signal, as measured by an EMG array. |
1 day visit
|
Medewerkers en onderzoekers
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 124039
- IRB-17-155 (Andere identificatie: Worcester Polytechnic Institute)
- 5R42HD076519-03 (Subsidie/contract van de Amerikaanse NIH)
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .